The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Accuracy of Diagnostic Tests Read With and Without Clinical Information: A Systematic Review
Abstract
CONTEXT: Although it is common practice to read tests with clinical information, whether this improves or decreases the accuracy of test reading is uncertain. OBJECTIVE: To determine whether diagnostic tests are more accurate when read with clinical information or without it. DATA SOURCES: MEDLINE search (1966-December 2003) extended by search of reference lists and articles citing the articles retrieved (Web of Science, 1985-December 2003). STUDY SELECTION: All articles comparing the accuracy of tests read twice by the same readers, once without and once with clinical information, but otherwise under identical conditions. Only articles that reported sensitivity and specificity or receiver operating characteristic (ROC) curves were included. DATA EXTRACTION: Data were extracted by one author and reviewed independently by the other. When the data were difficult to interpret, differences were resolved by discussion. DATA SYNTHESIS: Sixteen articles met the inclusion criteria. Eleven articles compared areas under ROC curves for tests read with and without clinical information, and 5 compared only sensitivity and specificity. Ten articles used actual clinical information; 6 used constructed clinical information that was plausible. Overall, clinical information improved test reading accuracy although the effect was smaller in the articles using actual clinical information when compared with those using constructed clinical information. There were no instances in which clinical information resulted in significant reduction in test reading accuracy. In some instances, improved test reading accuracy came from improved sensitivity without loss of specificity. CONCLUSIONS: At least for the tests examined, the common practice of reading diagnostic tests with clinical information seems justified. Future studies should be designed to investigate the best way of providing clinical information. These studies should also give an estimate of the accuracy of clinical information used, display ROC curves with identified data points, and include a wider range of diagnostic tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationThe influence of clinical information on the reporting of CT by radiologists.
Leslie, A., Jones, A. J., & Goddard, P. R. (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.874.11271897 · Cited by 172
Cited by
Moons, K. G. M., Altman, D. G., Reitsma, J. B., Ioannidis, J. P. A., Macaskill, P., Steyerberg, E. W., Vickers, A. J., Ransohoff, D. F., & Collins, G. S. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0698 · Cited by 5,147
Collins, R., Burch, J., Cranny, G., Aguiar-Ibáñez, R., Craig, D., Wright, K., Berry, E., Gough, M., Kleijnen, J., & Westwood, M. (2007) · BMJ · doi:10.1136/bmj.39217.473275.55 · Cited by 287
Bias in Radiology: The How and Why of Misses and Misinterpretations
Busby, L. P., Courtier, J. L., & Glastonbury, C. M. (2018) · RadioGraphics · doi:10.1148/rg.2018170107 · Cited by 277
Interpretive Error in Radiology
Waite, S., Scott, J., Gale, B., Fuchs, T., Kolla, S., & Reede, D. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.16963 · Cited by 271
Perceptual and interpretive error in diagnostic radiology—causes and potential solutions
Degnan, A. J., Ghobadi, E. H., Hardy, P., Krupinski, E., Scali, E. P., Stratchko, L., Ulano, A., Walker, E., Wasnik, A. P., & Auffermann, W. F. (2019) · Academic Radiology · doi:10.1016/j.acra.2018.11.006 · Cited by 121
Metadata
- Authors
- Loy, C. T., & Irwig, L.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2004-10-06
- Volume
- 292
- Issue
- 13
- Pages
- 1602
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2060351513
- Cited by
- 213
- References
- 4
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Diagnostic Tests Read With and Without Clinical Information: A Systematic Review. https://app.cochat.ai/papers/10.1001/jama.292.13.1602
- The paper
- Loy, C. T., & Irwig, L. (2004). Accuracy of Diagnostic Tests Read With and Without Clinical Information: A Systematic Review. JAMA. https://doi.org/10.1001/jama.292.13.1602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.