Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Open accessThe DOI matches its Crossref record; 21 of the 23 references it cites were found in a registry or an index.
Abstract
Objective To improve the accuracy and completeness of reporting of studies of diagnostic accuracy, to allow readers to assess the potential for bias in the study and to evaluate its generalisability.Methods The Standards for Reporting of Diagnostic Accuracy (STARD) steering group searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a two-day consensus meeting with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy.Results The search for published guidelines regarding diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25-item checklist, using evidence, whenever available. A prototypical flow diagram provides information about the method of patient recruitment, the order of test execution and the numbers of patients undergoing the test under evaluation, the reference standard or both.Conclusions Evaluation of research depends on complete and accurate reporting. If medical journals adopt the checklist and the flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of the clinicians, researchers, reviewers, journals, and the public.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“studies all contain many items that are relevant to studies developing or validating prediction models.However, none of these guidelines are entirely appropriate for prediction model studies.”
From Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD): The TRIPOD Statement (2015) · cites this paper as [39]
In the citing paper
“While making revisions, conscious efforts were made to harmonize our recommendations with other reporting guidelines, and where possible we chose the same or similar wording for items (37,39,41,45,46).”
From Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD): The TRIPOD Statement (2015) · cites this paper as [39]
In the citing paper
“However, none of these guidelines are entirely appropriate for prediction model studies.”
From Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD): The TRIPOD Statement (2015) · cites this paper as [40]
In the citing paper
“Publishing in a radiology journal [28] and a clinical chemistry journal [29] likely increased the reach and potential influence of the guidance.”
From Guidance for Developers of Health Research Reporting Guidelines (2010) · cites this paper as [28]
Citations
Cites
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Improving the Quality of Reporting of Randomized Controlled Trials: The CONSORT Statement
Begg, C. (1996) · JAMA · doi:10.1001/jama.1996.03540080059030 · Cited by 3,127
Moher, D. (2001) · JAMA · doi:10.1001/jama.285.15.1987 · Cited by 2,545
Self-citationThe International Committee of Medical Journal Editors
van der Weyden, M. (2006) · Proceedings of the Workshop on Publishing for Biomedical Journal Editors and Reviewers · doi:10.2349/biij.2.4.e54-13 · Cited by 1,998
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Self-citationThe Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citationMoher, D., Jones, A., Lepage, L., & for the CONSORT Group (2001) · JAMA · doi:10.1001/jama.285.15.1992 · Cited by 1,027
Self-citationSelection and interpretation of diagnostic tests and procedures. Principles and applications.
Griner, P. F., Mayewski, R. J., Mushlin, A. I., & Greenland, P. (1981) · PubMed · Cited by 765
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Research works printed but not linked: 1
- 10.1001/jama.1995.03530080061042 · doi:10.1001/jama.1995.03530080061042 · Paper page
Cited by
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61602-x · Cited by 21,320
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010 · Cited by 17,796
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
the CONSORT Group, Schulz, K. F., Altman, D. G., & Moher, D. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-18 · Cited by 13,371
Self-citation
Metadata
- Authors
- Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W.
- Affiliations
- The University of Sydney (AU)
- Corresponding author
- Bossuyt, Patrick M.
- Reitsma, Johannes B.
- Bruns, David E.
- Gatsonis, Constantine A
- Glasziou, Paul P.
- Irwig, Les M.
- Lijmer, Jeroen G.
- Moher, David
- Rennie, Drummond
- ORCID
- Venue
- Radiology
- Published
- 2003-01
- Volume
- 226
- Issue
- 1
- Pages
- 24-28
- ISSN
- 0009-9120 (ISSN-L)
- 0033-8419
- 1527-1315
- PMC
- PMC1124931
- OpenAlex
- W1492309945
- Cited by
- 3,215
- References
- 23
- Citations by year
- 2026: 30 · 2025: 29 · 2024: 36 · 2023: 39 · 2022: 43 · 2021: 82 · 2020: 86 · 2019: 91 · 2018: 110 · 2017: 136 · 2016: 173 · 2015: 255 · 2014: 248 · 2013: 231 · 2012: 274
- FWCI
- 159.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Biochemistry (publishedVersion)
- Clinical Radiology (publishedVersion)
- Family Practice (publishedVersion)
- Veterinary Clinical Pathology (publishedVersion)
- BMJ (publishedVersion)
- Radiology (publishedVersion)
- Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
- Clinical Chemistry (publishedVersion)
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- Annals of Internal Medicine (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- UvA-DARE (University of Amsterdam) (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Bond University Research Portal (Bond University) (submittedVersion, other-oa)
- Bond University Research Portal (Bond University) (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Bond University Research Portal (Bond University) (submittedVersion, cc-by-nc-nd)
- HighWire Press Open Archive (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Journal of Biological Chemistry
- Zhongguo xunzheng yixue zazhi
- Funders
- Medical Research Council
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- diagnostic accuracy, reporting guidelines, STARD, reporting checklist, flowcharts, consensus development, bias assessment, generalizability, reference materials
- MeSH terms
- Algorithms, Clinical Trials as Topic, Publishing, Research Design, Bias, Guidelines as Topic, Diagnostic Techniques and Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative. https://app.cochat.ai/papers/10.1148/radiol.2261021292
- The paper
- Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003). Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative. Radiology. https://doi.org/10.1148/radiol.2261021292
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.