Sirolimus-Eluting vs Uncoated Stents for Prevention of Restenosis in Small Coronary Arteries: A Randomized Trial
Abstract
CONTEXT: Percutaneous coronary revascularization of small vessels is associated with a high restenosis rate. Sirolimus-eluting stents reduce restenosis in simple and previously untreated lesions of large coronary arteries, but their outcomes in small vessels have not been adequately investigated. OBJECTIVE: To determine whether sirolimus-eluting stents are associated with a reduced 8-month rate of angiographic restenosis in comparison with an uncoated stent. DESIGN, SETTING, AND PATIENTS: This was a randomized, multicenter, single-blind, prospective trial performed with 257 patients undergoing percutaneous coronary revascularization for ischemic heart disease, and who had a previously untreated atherosclerotic lesion located in a small segment with a diameter of 2.75 mm or less, in 20 Italian centers between August 2002 and December 2003. INTERVENTION: Patients were randomly assigned to receive a sirolimus-eluting stent (129 patients) or an uncoated stent having an identical architecture and radiographic appearance (128 patients). MAIN OUTCOME MEASURES: The primary end point was the 8-month binary in-segment restenosis rate; secondary end points included procedural success and the 8-month rate of major adverse cardiac and cerebrovascular events. RESULTS: The mean (SD) reference diameter of the treated segment was 2.2 (0.28) mm; the lesion length, 11.84 (6.15) mm. After 8 months, the binary in-segment restenosis rate was 53.1% (60/113) in the patients receiving an uncoated stent and 9.8% (12/123) in those receiving a sirolimus-eluting stent (relative risk [RR], 0.18; 95% confidence interval [CI], 0.10-0.32; P<.001). Fewer patients randomized to sirolimus-eluting stents experienced major adverse cardiac events (12/129 [9.3%] vs 40/128 [31.3%]; RR, 0.30; 95% CI, 0.15-0.55; P<.001) mainly because of a reduction in target lesion revascularization (9/129 [7%] vs 27/128 [21.1%]; RR, 0.33; 95% CI, 0.14-0.70; P = .002) and myocardial infarction (2/129 [1.6%] vs 10/129 [7.8%]; RR, 0.20; 95% CI, 0.01-0.93; P = .04). CONCLUSION: The use of sirolimus-eluting stents to treat atherosclerotic lesions in small coronary arteries reduces restenosis and may also reduce major adverse cardiac events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Targets for Cell Cycle Arrest by the Immunosuppressant Rapamycin in Yeast
Heitman, J., Movva, N. R., & Hall, M. N. (1991) · Science · doi:10.1126/science.1715094 · Cited by 2,006
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Cited by
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Analysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., Menichelli, M., Sabaté, M., Suttorp, M. J., Baumgart, D., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067484 · Cited by 1,006
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Metadata
- Authors
- Ardissino, D., Cavallini, C., Bramucci, E., Indolfi, C., Marzocchi, A., Manari, A., Angeloni, G., Carosio, G., Bonizzoni, E., Colusso, S., Repetto, M., Merlini, P. A., & SES-SMART Investigators, F. T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2004-12-08
- Volume
- 292
- Issue
- 22
- Pages
- 2727
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2139998313
- Cited by
- 314
- References
- 14
- FWCI
- 42.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sirolimus-Eluting vs Uncoated Stents for Prevention of Restenosis in Small Coronary Arteries: A Randomized Trial. https://app.cochat.ai/papers/10.1001/jama.292.22.2727
- The paper
- Ardissino, D., Cavallini, C., Bramucci, E., Indolfi, C., Marzocchi, A., Manari, A., Angeloni, G., Carosio, G., Bonizzoni, E., Colusso, S., Repetto, M., Merlini, P. A., & SES-SMART Investigators, F. T. (2004). Sirolimus-Eluting vs Uncoated Stents for Prevention of Restenosis in Small Coronary Arteries: A Randomized Trial. JAMA. https://doi.org/10.1001/jama.292.22.2727
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.