Vessel Size and Long-Term Outcome After Coronary Stent Placement

Elezi, Shpend, Kastrati, Adnan, Neumann, Franz-Josef, Hadamitzky, Martin, Dirschinger, Josef, Schömig, Albert·1998·Circulation

Abstract

Background —The role of coronary stenting in the treatment of patients with small vessels is not well defined. The purpose of this study was to investigate the influence of vessel size on long-term clinical and angiographic outcome after coronary stent placement. Methods and Results —The study comprised 2602 patients with successful stent implantation for symptomatic coronary artery disease. Patients were subdivided into 3 equally sized groups (tertiles) according to vessel size, with respective ranges of <2.8, 2.8 to 3.2, and >3.2 mm. Event-free survival at 1 year was 69.5% in the group with smaller vessels, 77.5% in the second group, and 81% in the group with larger vessels ( P <0.001). Late lumen loss was similar between the 3 groups (1.12±0.73, 1.12±0.79, and 1.09±0.88 mm, respectively). Angiographic restenosis rate was significantly higher in the small-vessel group (38.6%, 28.4%, and 20.4% in groups 1, 2, and 3, respectively; P <0.001). The analysis identified subgroups with different risk for restenosis even among patients with small vessels. Within this group, the restenosis rate may be as low as 29.6% in patients without additional risk factors and as high as 53.5% in patients with diabetes and complex lesions. Conclusions —Patients with small vessels present a higher risk for an adverse outcome after coronary stent placement because of a higher incidence of restenosis. However, the unusually high risk for restenosis is confined to those patients with small vessels who have concomitant risk factors such as diabetes and complex lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.18.1875

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 484

Metadata

Authors
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A.
Venue
Circulation
Published
1998-11-03
Volume
98
Issue
18
Pages
1875-1880
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2165993944
Cited by
484
References
13
FWCI
27.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vessel Size and Long-Term Outcome After Coronary Stent Placement. https://app.cochat.ai/papers/10.1161/01.cir.98.18.1875
The paper
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998). Vessel Size and Long-Term Outcome After Coronary Stent Placement. Circulation. https://doi.org/10.1161/01.cir.98.18.1875

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.