Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 313

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Clinical Validity of a Negative Computed Tomography Scan in Patients With Suspected Pulmonary Embolism: A Systematic Review

Quiroz, Rene, Kucher, Nils, Zou, Kelly H., Kipfmueller, Florian, Costello, Philip, Goldhaber, Samuel Z., Schoepf, U. Joseph · 2005 · JAMA

Abstract

CONTEXT: The clinical validity of using computed tomography (CT) to diagnose peripheral pulmonary embolism is uncertain. Insufficient sensitivity for peripheral pulmonary embolism is considered the principal limitation of CT. OBJECTIVE: To review studies that used a CT-based approach to rule out a diagnosis of pulmonary embolism. DATA SOURCES: The medical literature databases of PubMed, MEDLINE, EMBASE, CRISP, metaRegister of Controlled Trials, and Cochrane were searched for articles published in the English language from January 1990 to May 2004. STUDY SELECTION: We included studies that used contrast-enhanced chest CT to rule out the diagnosis of acute pulmonary embolism, had a minimum follow-up of 3 months, and had study populations of more than 30 patients. DATA EXTRACTION: Two reviewers independently abstracted patient demographics, frequency of venous thromboembolic events (VTEs), CT modality (single-slice CT, multidetector-row CT, or electron-beam CT), false-negative results, and deaths attributable to pulmonary embolism. To calculate the overall negative likelihood ratio (NLR) of a VTE after a negative or inconclusive chest CT scan for pulmonary embolism, we included VTEs that were objectively confirmed by an additional imaging test despite a negative or inconclusive CT scan and objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months. DATA SYNTHESIS: Fifteen studies met the inclusion criteria and contained a total of 3500 patients who were evaluated from October 1994 through April 2002. The overall NLR of a VTE after a negative chest CT scan for pulmonary embolism was 0.07 (95% confidence interval [CI], 0.05-0.11); and the negative predictive value (NPV) was 99.1% (95% CI, 98.7%-99.5%). The NLR of a VTE after a negative single-slice spiral CT scan for pulmonary embolism was 0.08 (95% CI, 0.05-0.13); and after a negative multidetector-row CT scan, 0.15 (95% CI, 0.05-0.43). There was no difference in risk of VTEs based on CT modality used (relative risk, 1.66; 95% CI, 0.47-5.94; P = .50). The overall NLR of mortality attributable to pulmonary embolism was 0.01 (95% CI, 0.01-0.02) and the overall NPV was 99.4% (95% CI, 98.7%-99.9%). CONCLUSION: The clinical validity of using a CT scan to rule out pulmonary embolism is similar to that reported for conventional pulmonary angiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.293.16.2012

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 313

Metadata

Authors
Quiroz, R., Kucher, N., Zou, K. H., Kipfmueller, F., Costello, P., Goldhaber, S. Z., & Schoepf, U. J.
Venue
JAMA
Published
2005-04-27
Volume
293
Issue
16
Pages
2012
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2112170924
Cited by
313
References
22
FWCI
27.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Validity of a Negative Computed Tomography Scan in Patients With Suspected Pulmonary Embolism: A Systematic Review. https://app.cochat.ai/papers/10.1001/jama.293.16.2012
The paper
Quiroz, R., Kucher, N., Zou, K. H., Kipfmueller, F., Costello, P., Goldhaber, S. Z., & Schoepf, U. J. (2005). Clinical Validity of a Negative Computed Tomography Scan in Patients With Suspected Pulmonary Embolism: A Systematic Review. JAMA. https://doi.org/10.1001/jama.293.16.2012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.