Sirolimus-Eluting Stent or Paclitaxel-Eluting Stent vs Balloon Angioplasty for Prevention of Recurrences in Patients With Coronary In-Stent Restenosis: A Randomized Controlled Trial
Abstract
CONTEXT: In patients with de novo coronary lesions, drug-eluting stents have drastically reduced restenosis risk compared with bare metal stents and conventional balloon angioplasty. It is less clear whether drug-eluting stents are superior to conventional balloon angioplasty for the treatment of patients with in-stent restenosis. OBJECTIVES: To assess if drug-eluting stents are a more effective treatment of in-stent restenosis than conventional balloon angioplasty, and to assess the relative merits of 2 drug-eluting stents, a sirolimus-eluting stent and a paclitaxel-eluting stent. DESIGN, SETTING, AND PARTICIPANTS: Randomized, open-label, active-controlled trial conducted among 300 patients with angiographically significant in-stent restenosis in 2 tertiary German centers from June 1, 2003, to October 20, 2003. INTERVENTIONS: After pretreatment with 600 mg of clopidogrel for at least 2 hours before intervention, all patients were randomly assigned to 1 of 3 treatment groups: sirolimus stent, paclitaxel stent, or balloon angioplasty (100 patients in each group). MAIN OUTCOME MEASURES: Primary end point: angiographic restenosis (diameter stenosis > or =50%) at 6-month follow-up angiography based on "in-segment" analysis. Primary analysis was comparison between stent groups and balloon angioplasty groups; a secondary analysis compared sirolimus and paclitaxel stents. RESULTS: Follow-up angiography was performed in 275 (92%) of 300 patients. The incidence of angiographic restenosis was 44.6% (41/92) in the balloon angioplasty group, 14.3% (13/91) in the sirolimus stent group (P<.001 vs balloon angioplasty), and 21.7% (20/92) in the paclitaxel stent group (P = .001 vs balloon angioplasty). When compared with balloon angioplasty, receiving a sirolimus stent had a relative risk (RR) of angiographic restenosis of 0.32 (95% confidence interval [CI], 0.18-0.56); a paclitaxel stent had an RR of 0.49 (95% CI, 0.31-0.76). The incidence of target vessel revascularization was 33.0% (33/100) in the balloon angioplasty group, 8.0% (8/100) in the sirolimus stent group (P<.001 vs balloon angioplasty), and 19.0% (19/100) in the paclitaxel stent group (P = .02 vs balloon angioplasty). The secondary analysis showed a trend toward a lower rate of angiographic restenosis (P = .19) and a significantly lower rate of target vessel revascularization (P = .02) among sirolimus stent patients compared with paclitaxel stent patients. CONCLUSIONS: In patients with in-stent restenosis, a strategy based on sirolimus- or paclitaxel-eluting stents is superior to conventional balloon angioplasty for the prevention of recurrent restenosis. Sirolimus-eluting stents may be superior to paclitaxel-eluting stents for treatment of this disorder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citation(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Metadata
- Authors
- Kastrati, A., Mehilli, J., von Beckerath, N., Dibra, A., Hausleiter, J., Pache, J., Schühlen, H., Schmitt, C., Dirschinger, J., Schömig, A., & ISAR-DESIRE Study Investigators, F. T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2005-01-12
- Volume
- 293
- Issue
- 2
- Pages
- 165-71
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2111592624
- Cited by
- 605
- References
- 0
- FWCI
- 75.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sirolimus-Eluting Stent or Paclitaxel-Eluting Stent vs Balloon Angioplasty for Prevention of Recurrences in Patients With Coronary In-Stent Restenosis: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1001/jama.293.2.165
- The paper
- Kastrati, A., Mehilli, J., von Beckerath, N., Dibra, A., Hausleiter, J., Pache, J., Schühlen, H., Schmitt, C., Dirschinger, J., Schömig, A., & ISAR-DESIRE Study Investigators, F. T. (2005). Sirolimus-Eluting Stent or Paclitaxel-Eluting Stent vs Balloon Angioplasty for Prevention of Recurrences in Patients With Coronary In-Stent Restenosis: A Randomized Controlled Trial. JAMA. https://doi.org/10.1001/jama.293.2.165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.