CoChat
Cited by 605

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Sirolimus-Eluting Stent or Paclitaxel-Eluting Stent vs Balloon Angioplasty for Prevention of Recurrences in Patients With Coronary In-Stent Restenosis: A Randomized Controlled Trial

Kastrati, Adnan, Mehilli, Julinda, von Beckerath, Nicolas, Dibra, Alban, Hausleiter, Jörg, Pache, Jürgen, Schühlen, Helmut, Schmitt, Claus, Dirschinger, Josef, Schömig, Albert, ISAR-DESIRE Study Investigators, for the · 2005 · JAMA

Abstract

CONTEXT: In patients with de novo coronary lesions, drug-eluting stents have drastically reduced restenosis risk compared with bare metal stents and conventional balloon angioplasty. It is less clear whether drug-eluting stents are superior to conventional balloon angioplasty for the treatment of patients with in-stent restenosis. OBJECTIVES: To assess if drug-eluting stents are a more effective treatment of in-stent restenosis than conventional balloon angioplasty, and to assess the relative merits of 2 drug-eluting stents, a sirolimus-eluting stent and a paclitaxel-eluting stent. DESIGN, SETTING, AND PARTICIPANTS: Randomized, open-label, active-controlled trial conducted among 300 patients with angiographically significant in-stent restenosis in 2 tertiary German centers from June 1, 2003, to October 20, 2003. INTERVENTIONS: After pretreatment with 600 mg of clopidogrel for at least 2 hours before intervention, all patients were randomly assigned to 1 of 3 treatment groups: sirolimus stent, paclitaxel stent, or balloon angioplasty (100 patients in each group). MAIN OUTCOME MEASURES: Primary end point: angiographic restenosis (diameter stenosis > or =50%) at 6-month follow-up angiography based on "in-segment" analysis. Primary analysis was comparison between stent groups and balloon angioplasty groups; a secondary analysis compared sirolimus and paclitaxel stents. RESULTS: Follow-up angiography was performed in 275 (92%) of 300 patients. The incidence of angiographic restenosis was 44.6% (41/92) in the balloon angioplasty group, 14.3% (13/91) in the sirolimus stent group (P<.001 vs balloon angioplasty), and 21.7% (20/92) in the paclitaxel stent group (P = .001 vs balloon angioplasty). When compared with balloon angioplasty, receiving a sirolimus stent had a relative risk (RR) of angiographic restenosis of 0.32 (95% confidence interval [CI], 0.18-0.56); a paclitaxel stent had an RR of 0.49 (95% CI, 0.31-0.76). The incidence of target vessel revascularization was 33.0% (33/100) in the balloon angioplasty group, 8.0% (8/100) in the sirolimus stent group (P<.001 vs balloon angioplasty), and 19.0% (19/100) in the paclitaxel stent group (P = .02 vs balloon angioplasty). The secondary analysis showed a trend toward a lower rate of angiographic restenosis (P = .19) and a significantly lower rate of target vessel revascularization (P = .02) among sirolimus stent patients compared with paclitaxel stent patients. CONCLUSIONS: In patients with in-stent restenosis, a strategy based on sirolimus- or paclitaxel-eluting stents is superior to conventional balloon angioplasty for the prevention of recurrent restenosis. Sirolimus-eluting stents may be superior to paclitaxel-eluting stents for treatment of this disorder.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.293.2.165

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Kastrati, A., Mehilli, J., von Beckerath, N., Dibra, A., Hausleiter, J., Pache, J., Schühlen, H., Schmitt, C., Dirschinger, J., Schömig, A., & ISAR-DESIRE Study Investigators, F. T.
Venue
JAMA
Published
2005-01-12
Volume
293
Issue
2
Pages
165-71
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2111592624
Cited by
605
References
12
FWCI
75.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.