Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 557

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Distal Microcirculatory Protection During Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>

Stone, Gregg W.·2005·JAMA

Abstract

CONTEXT: Atheromatous and thrombotic embolization during percutaneous coronary intervention (PCI) in acute myocardial infarction is common and may result in microcirculatory dysfunction, the prevention of which may improve reperfusion success, reduce infarct size, and enhance event-free survival. OBJECTIVE: To determine whether protection of the distal microcirculation from thromboembolic debris liberated during primary PCI results in improved reperfusion and decreased infarct size. DESIGN, SETTING, AND PATIENTS: Prospective randomized controlled trial at 38 academic and community-based institutions in 7 countries enrolling 501 patients aged 18 years or older with ST-segment elevation myocardial infarction (STEMI) presenting within 6 hours of symptom onset and undergoing primary PCI or rescue intervention after failed thrombolysis. INTERVENTIONS: Patients were randomized between May 20, 2002, and November 21, 2003, to receive PCI with a balloon occlusion and aspiration distal microcirculatory protection system vs angioplasty without distal protection. MAIN OUTCOME MEASURES: Coprimary end points were ST-segment resolution (STR) measured 30 minutes after PCI by continuous Holter monitoring and infarct size measured by technetium Tc 99m sestamibi imaging between days 5 and 14. Secondary end points included major adverse cardiac events. RESULTS: Among 252 patients assigned to distal protection, aspiration was performed in 97% (242/251), all angioplasty balloon inflations were fully protected in 79% (193/245), and visible debris was retrieved from 73% (182/250). Complete STR was achieved in a similar proportion reperfused with vs without distal protection (63.3% [152/240] vs 61.9% [148/239], respectively; absolute difference, 1.4% [95% confidence interval, -7.7% to 10.5%; P = .78]), and left ventricular infarct size was similar in both groups (median, 12.0% [n = 229] vs 9.5% [n = 208], respectively; P = .15). Major adverse cardiac events at 6 months occurred with similar frequency in the distal protection and control groups (10.0% vs 11.0%, respectively; P = .66). CONCLUSIONS: A distal balloon occlusion and aspiration system effectively retrieves embolic debris in most patients with acute STEMI undergoing emergent PCI. Nonetheless, distal embolic protection did not result in improved microvascular flow, greater reperfusion success, reduced infarct size, or enhanced event-free survival.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.293.9.1063

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 557

Metadata

Authors
Stone, G. W.
Venue
JAMA
Published
2005-03-02
Volume
293
Issue
9
Pages
1063
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2108082043
Cited by
557
References
32
FWCI
42.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distal Microcirculatory Protection During Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>. https://app.cochat.ai/papers/10.1001/jama.293.9.1063
The paper
Stone, G. W. (2005). Distal Microcirculatory Protection During Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>. JAMA. https://doi.org/10.1001/jama.293.9.1063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.