The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Sirolimus-Eluting Stents vs Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease: Meta-analysis of Randomized Trials
Abstract
CONTEXT: Placement of sirolimus-eluting stents or paclitaxel-eluting stents has emerged as the predominant percutaneous treatment strategy in patients with coronary artery disease (CAD). Whether there are any differences in efficacy and safety between these 2 drug-eluting stents is unclear. OBJECTIVE: To compare outcomes of sirolimus-eluting and paclitaxel-eluting coronary stents on the basis of data generated by randomized head-to-head clinical trials. DATA SOURCES: PubMed and the Cochrane Central Register of Controlled Trials, conference proceedings from major cardiology meetings, and Internet-based sources of information on clinical trials in cardiology from January 2003 to April 2005. STUDY SELECTION: Randomized trials comparing the sirolimus-eluting stent with the paclitaxel-eluting stent in patients with CAD reporting the outcomes of interest (target lesion revascularization, angiographic restenosis, stent thrombosis, myocardial infarction [MI], death, and the composite of death or MI) during a follow-up of at least 6 months. DATA EXTRACTION: Two reviewers independently identified studies and abstracted data on sample size, baseline characteristics, and outcomes of interest. DATA SYNTHESIS: Six trials, including 3669 patients, met the selection criteria. No significant heterogeneity was found across trials. Target lesion revascularization, the primary outcome of interest, was less frequently performed in patients who were treated with the sirolimus-eluting stent (5.1%) vs the paclitaxel-eluting stent (7.8%) (odds ratio [OR], 0.64; 95% confidence interval [CI], 0.49-0.84; P = .001). Similarly, angiographic restenosis was less frequently observed among patients assigned to the sirolimus-eluting stent (9.3%) vs the paclitaxel-eluting stent (13.1%) (OR, 0.68; 95% CI, 0.55-0.86; P = .001). Event rates for sirolimus-eluting vs paclitaxel-eluting stents were 0.9% and 1.1%, respectively, for stent thrombosis (P = .62); 1.4% and 1.6%, respectively, for death (P = .56); and 4.9% and 5.8%, respectively, for the composite of death or MI (P = .23). CONCLUSIONS: Patients receiving sirolimus-eluting stents had a significantly lower risk of restenosis and target vessel revascularization compared with those receiving paclitaxel-eluting stents. Rates of death, death or MI, and stent thrombosis were similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“The pooled OR was calculated with the Mantel-Haenszel method for fixed effects(19) and the DerSimonian and Laird method for random effects.(20) To assess heterogeneity across trials, we used the Cochran Q test based on the pooled OR by Mantel-Haenszel.”
MethodOperating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
Statistical Aspects of the Analysis of Data From Retrospective Studies of Disease
(1959) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/22.4.719 · Cited by 14,689
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Assessing the quality of controlled clinical trials
Jüni, P., Altman, D. G., & Egger, M. (2001) · BMJ · doi:10.1136/bmj.323.7303.42 · Cited by 3,309
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Meta-analysis: Principles and procedures
Egger, M., Smith, G. D., & Phillips, A. N. (1997) · BMJ · doi:10.1136/bmj.315.7121.1533 · Cited by 2,415
Cited by
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis
Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.087 · Cited by 1,516
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationKing, S. B., Smith, S. C., Hirshfeld, J. W., Jacobs, A. K., Morrison, D. A., Williams, D. O., 2005 WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.188208 · Cited by 1,014
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Nordmann, A. J., Briel, M., & Bucher, H. C. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl282 · Cited by 480
Morice, M.-C., Colombo, A., Meier, B., Serruys, P., Tamburino, C., Guagliumi, G., Sousa, E., Stoll, H.-P., & REALITY Trial Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.295.8.895 · Cited by 458
Sarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr479 · Cited by 378
Schömig, A., Dibra, A., Windecker, S., Mehilli, J., Suárez de Lezo, J., Kaiser, C., Park, S.-J., Goy, J.-J., Lee, J.-H., Di Lorenzo, E., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.047 · Cited by 359
Self-citationKandzari, D. E., Leon, M. B., Popma, J. J., Fitzgerald, P. J., O’Shaughnessy, C., Ball, M. W., Turco, M., Applegate, R. J., Gurbel, P. A., Midei, M. G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.035 · Cited by 347
Kaiser, C., Brunner-La Rocca, H. P., Buser, P. T., Bonetti, P. O., Osswald, S., Linka, A., Bernheim, A., Zutter, A., Zellweger, M., Grize, L., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67221-2 · Cited by 342
Kastrati, A., Dibra, A., Mehilli, J., Mayer, S., Pinieck, S., Pache, J., Dirschinger, J., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.601823 · Cited by 312
Self-citation
Metadata
- Authors
- Kastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2005-08-17
- Volume
- 294
- Issue
- 7
- Pages
- 819
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2005002677
- Cited by
- 282
- References
- 24
- FWCI
- 47.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.