Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 378

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Lower risk of stent thrombosis and restenosis with unrestricted use of ‘new-generation’ drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR)

Open access
Sarno, Giovanna, Lagerqvist, Bo, Fröbert, Ole, Nilsson, Johan, Olivecrona, Göran, Omerovic, Elmir, Saleh, Nawzad, Venetzanos, Dimitris, James, Stefan·2012·European Heart Journal

Abstract

AIMS: To compare the long-term outcome after percutaneous coronary intervention with 'new-generation' drug-eluting stents (n-DES) to 'older generation' DES (o-DES), and bare-metal stents (BMS) in a real-world population. METHODS AND RESULTS: We evaluated 94 384 consecutive stent implantations (BMS, n = 64 631; o-DES, n = 19 202; n-DES, n = 10 551) in Sweden from November 2006 to October 2010. All cases of definite stent thrombosis (ST) and restenosis were documented in the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Older generation DES were classified as: Cypher and Cypher Select (Cordis Corporation, Miami, FL, USA), Taxus Express and Taxus Liberté (Boston Scientific Corporation), and Endeavor (Medtronic Inc.) and n-DES as: Endeavor Resolute (Medtronic Inc.), XienceV, Xience Prime (Abbott Laboratories) and Promus, Promus Element (Boston Scientific Corporation). The Cox regression analyses unadjusted and adjusted for clinical and angiographic covariates showed a statistically significant lower risk of restenosis in n-DES compared with BMS [adjusted hazard ratio (HR) 0.29; 95% confidence interval (CI): 0.25-0.33] and o-DES (HR 0.62; 95% CI: 0.53-0.72). A lower risk of definite ST was found in n-DES compared with BMS (HR 0.38; 95% CI: 0.28-0.52) and o-DES (HR, 0.57; 95% CI: 0.41-0.79). The risk of death was significantly lower in n-DES compared with o-DES (adjusted HR: 0.77; 95% CI: 0.63-0.95) and BMS (adjusted HR: 0.55; 95% CI: 0.46-0.67). CONCLUSION: Percutaneous coronary intervention with n-DES is associated with a 38% lower risk of clinically meaningful restenosis, a 43% lower risk of definite ST, and a 23% lower risk of death compared with o-DES in this observational study from a large real-world population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehr479

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 378

Metadata

Authors
Sarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S.
Venue
European Heart Journal
Published
2012-01-09
Volume
33
Issue
5
Pages
606-613
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2109100788
Cited by
378
References
34
FWCI
49.91
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lower risk of stent thrombosis and restenosis with unrestricted use of ‘new-generation’ drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). https://app.cochat.ai/papers/10.1093/eurheartj/ehr479
The paper
Sarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S. (2012). Lower risk of stent thrombosis and restenosis with unrestricted use of ‘new-generation’ drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). European Heart Journal. https://doi.org/10.1093/eurheartj/ehr479

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.