Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Importance: Emergency department (ED) investigations of patients with suspected acute myocardial infarction (AMI) are time consuming, partly because of the turnaround time of laboratory tests. Current point-of-care troponin assays shorten test turnaround times but lack precision at lower concentrations. Development of point-of-care troponin assays with greater analytical precision could reduce the decision-making time in EDs for ruling out AMI. Objective: To determine the clinical accuracy for AMI of a single troponin concentration measured on arrival to ED with a new-generation, higher precision point-of-care assay with a 15-minute turnaround time. Design, Setting, and Participants: This observational study occurred at a single urban regional ED. Adults presenting acutely from the community to the ED with symptoms suggestive of AMI were included. Troponin concentrations were measured on ED arrival with both a novel point-of-care assay (i-STAT TnI-Nx; Abbott Point of Care) and a high-sensitivity troponin I assay (Architect hs-cTnI; Abbott Diagnostics). Main Outcomes and Measures: The primary outcome was type 1 AMI during index presentation. We compared the discrimination ability of the TnI-Nx assay with the hs-cTnI assay using the area under receiver operator characteristic curve (AUC) and sensitivity, negative predictive value, and the proportion of negative test results at thresholds with 100% sensitivity. Results: Of 354 patients (255 [72.0%] men; mean [SD] age, 62 [12] years), 57 (16.1%) experienced an AMI. Eighty-five patients (24.0%) presented to the ED less than 3 hours after symptom onset. No difference was found between the AUC of the TnI-Nx assay (0.975 [95% CI, 0.958-0.993]) and the hs-cTnI assay (0.970 [95% CI, 0.949 to 0.990]; P = .46). A TnI-Nx assay result of less than 11 ng/L identified 201 patients (56.7%) as low risk, with a sensitivity of 100% (95% CI, 93.7%-100%) and a negative predictive value of 100% (95% CI, 98.2%-100%). In comparison, an hs-cTnI assay result of less than 3 ng/L identified 154 patients (43.5%) as low risk, with a sensitivity of 100% (95% CI, 93.7%-100%) and a negative predictive value of 100% (95% CI, 97.6%-100%). Conclusions and Relevance: A novel point-of-care troponin assay that can produce a result 15 minutes after blood sampling had comparable discrimination ability to an hs-cTnI assay for ruling out AMI after a single blood test. Use in the ED may facilitate earlier decision making and could expedite the safe discharge of a large proportion of low-risk patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Circulation · doi:10.1161/cir.0b013e31826e1058 · Cited by 2,985
Cited by
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad191 · Cited by 5,333
Collet, J.-P., Thiele, H., Barbato, E., Barthélémy, O., Bauersachs, J., Bhatt, D. L., Dendale, P., Dorobantu, M., Edvardsen, T., Folliguet, T., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa575 · Cited by 5,037
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2024) · European Heart Journal: Acute Cardiovascular Care · doi:10.1093/ehjacc/zuad107 · Cited by 314
Safety, Efficiency, and Cost Conflicts in Emergency Department Point of Care Troponin Testing
Grabinski, Z., Swartz, J. L., Wang, Y., Itani, A., Aguero-Rosenfeld, M., Sanchez, N., Gulati, R., Wittman, I. G., & Smith, S. W. (2026) · Quality Management in Health Care · doi:10.1097/qmh.0000000000000502
Metadata
- Authors
- Pickering, J. W., Young, J. M., George, P. M., Watson, A. S., Aldous, S. J., Troughton, R. W., Pemberton, C. J., Richards, A. M., Cullen, L. A., & Than, M. P.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2018-11-01
- Volume
- 3
- Issue
- 11
- Pages
- 1108
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W2897693688
- Cited by
- 81
- References
- 1
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction. https://app.cochat.ai/papers/10.1001/jamacardio.2018.3368
- The paper
- Pickering, J. W., Young, J. M., George, P. M., Watson, A. S., Aldous, S. J., Troughton, R. W., Pemberton, C. J., Richards, A. M., Cullen, L. A., & Than, M. P. (2018). Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction. JAMA Cardiology. https://doi.org/10.1001/jamacardio.2018.3368
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.