Evaluation of Deep Learning Models for Identifying Surgical Actions and Measuring Performance
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Importance: When evaluating surgeons in the operating room, experienced physicians must rely on live or recorded video to assess the surgeon's technical performance, an approach prone to subjectivity and error. Owing to the large number of surgical procedures performed daily, it is infeasible to review every procedure; therefore, there is a tremendous loss of invaluable performance data that would otherwise be useful for improving surgical safety. Objective: To evaluate a framework for assessing surgical video clips by categorizing them based on the surgical step being performed and the level of the surgeon's competence. Design, Setting, and Participants: This quality improvement study assessed 103 video clips of 8 surgeons of various levels performing knot tying, suturing, and needle passing from the Johns Hopkins University-Intuitive Surgical Gesture and Skill Assessment Working Set. Data were collected before 2015, and data analysis took place from March to July 2019. Main Outcomes and Measures: Deep learning models were trained to estimate categorical outputs such as performance level (ie, novice, intermediate, and expert) and surgical actions (ie, knot tying, suturing, and needle passing). The efficacy of these models was measured using precision, recall, and model accuracy. Results: The provided architectures achieved accuracy in surgical action and performance calculation tasks using only video input. The embedding representation had a mean (root mean square error [RMSE]) precision of 1.00 (0) for suturing, 0.99 (0.01) for knot tying, and 0.91 (0.11) for needle passing, resulting in a mean (RMSE) precision of 0.97 (0.01). Its mean (RMSE) recall was 0.94 (0.08) for suturing, 1.00 (0) for knot tying, and 0.99 (0.01) for needle passing, resulting in a mean (RMSE) recall of 0.98 (0.01). It also estimated scores on the Objected Structured Assessment of Technical Skill Global Rating Scale categories, with a mean (RMSE) precision of 0.85 (0.09) for novice level, 0.67 (0.07) for intermediate level, and 0.79 (0.12) for expert level, resulting in a mean (RMSE) precision of 0.77 (0.04). Its mean (RMSE) recall was 0.85 (0.05) for novice level, 0.69 (0.14) for intermediate level, and 0.80 (0.13) for expert level, resulting in a mean (RMSE) recall of 0.78 (0.03). Conclusions and Relevance: The proposed models and the accompanying results illustrate that deep machine learning can identify associations in surgical video clips. These are the first steps to creating a feedback mechanism for surgeons that would allow them to learn from their experiences and refine their skills.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extracting and composing robust features with denoising autoencoders
Vincent, P., Larochelle, H., Bengio, Y., & Manzagol, P.-A. (2008) · Proceedings of the 25th international conference on Machine learning - ICML '08 · doi:10.1145/1390156.1390294 · Cited by 7,436
He, K., Gkioxari, G., Dollar, P., & Girshick, R. (2020) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2018.2844175 · Cited by 3,457
Objective structured assessment of technical skill (OSATS) for surgical residents
Martin, J. A., Regehr, G., Reznick, R., Macrae, H., Murnaghan, J., Hutchison, C., & Brown, M. (1997) · British Journal of Surgery · doi:10.1002/bjs.1800840237 · Cited by 2,527
EndoNet: A Deep Architecture for Recognition Tasks on Laparoscopic Videos
Twinanda, A. P., Shehata, S., Mutter, D., Marescaux, J., de Mathelin, M., & Padoy, N. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2593957 · Cited by 1,096
A global assessment tool for evaluation of intraoperative laparoscopic skills
Vassiliou, M. C., Feldman, L. S., Andrew, C. G., Bergman, S., Leffondré, K., Stanbridge, D., & Fried, G. M. (2005) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2005.04.004 · Cited by 917 · cited 1×
“For example, an autoencoder neural network can consist of 2 stages, as follows: (1) an encoder that compresses information into the embedding and (2) a decoder that tries to reconstruct the original input from the embedding.”
MethodHe, K., Gkioxari, G., Dollár, P., & Girshick, R. (2017) · arXiv · doi:10.48550/arxiv.1703.06870 · Cited by 406
Jin, A., Yeung, S., Jopling, J., Krause, J., Azagury, D., Milstein, A., & Fei-Fei, L. (2018) · 2018 IEEE Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv.2018.00081 · Cited by 323
Niitsu, H., Hirabayashi, N., Yoshimitsu, M., Mimura, T., Taomoto, J., Sugiyama, Y., Murakami, S., Saeki, S., Mukaida, H., & Takiyama, W. (2013) · Surgery Today · doi:10.1007/s00595-012-0313-7 · Cited by 280 · cited 1×
“For example, an autoencoder neural network can consist of 2 stages, as follows: (1) an encoder that compresses information into the embedding and (2) a decoder that tries to reconstruct the original input from the embedding.”
MethodWang, Z., & Majewicz Fey, A. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1860-1 · Cited by 275
(2006) · doi:10.1002/(issn)1365-2168 · Cited by 246
Cited by
Deep learning-enabled medical computer vision
Esteva, A., Chou, K., Yeung, S., Naik, N., Madani, A., Mottaghi, A., Liu, Y., Topol, E., Dean, J., & Socher, R. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00376-2 · Cited by 1,406
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
“Ambient cameras are an unobtrusive alternative 46 .”
BackgroundA systematic review on artificial intelligence in robot-assisted surgery
Moglia, A., Georgiou, K., Georgiou, E., Satava, R. M., & Cuschieri, A. (2021) · International Journal of Surgery · doi:10.1016/j.ijsu.2021.106151 · Cited by 236
Artificial intelligence surgery: how do we get to autonomous actions in surgery?
Gumbs, A. A., Frigerio, I., Spolverato, G., Croner, R., Illanes, A., Chouillard, E., & Elyan, E. (2021) · Sensors · doi:10.3390/s21165526 · Cited by 161
“However, despite the availability of these videos, their use in training is still limited, because these videos require some sort of pre-processing, and also the segmentation into different phases for subsequent automated skill assessment and feedback [15].”
BackgroundMethodInfluentialArtificial Intelligence and Surgical Education: A Systematic Scoping Review of Interventions
Kirubarajan, A., Young, D., Khan, S., Crasto, N., Sobel, M., & Sussman, D. (2022) · Journal of Surgical Education · doi:10.1016/j.jsurg.2021.09.012 · Cited by 101
Metadata
- Authors
- Khalid, S., Goldenberg, M., Grantcharov, T., Taati, B., & Rudzicz, F.
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2020-03-30
- Volume
- 3
- Issue
- 3
- Pages
- e201664
- ISSN
- 2574-3805 (ISSN-L)
- OpenAlex
- W3013053228
- Cited by
- 159
- References
- 21
- FWCI
- 18.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Deep Learning Models for Identifying Surgical Actions and Measuring Performance. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2020.1664
- The paper
- Khalid, S., Goldenberg, M., Grantcharov, T., Taati, B., & Rudzicz, F. (2020). Evaluation of Deep Learning Models for Identifying Surgical Actions and Measuring Performance. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2020.1664
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.