Cited by 236Surgical Simulation and TrainingArtificial Intelligence in Healthcare and EducationRobot Manipulation and Learning

A systematic review on artificial intelligence in robot-assisted surgery

Moglia, Andrea, Georgiou, Konstantinos, Georgiou, Evangelos, Satava, Richard M., Cuschieri, Alfred·2021·International Journal of Surgery

Abstract

Background Despite the extensive published literature on the significant potential of artificial intelligence (AI) there are no reports on its efficacy in improving patient safety in robot-assisted surgery (RAS). The purposes of this work are to systematically review the published literature on AI in RAS, and to identify and discuss current limitations and challenges. Materials and methods A literature search was conducted on PubMed, Web of Science, Scopus, and IEEExplore according to PRISMA 2020 statement. Eligible articles were peer-review studies published in English language from January 1, 2016 to December 31, 2020. Amstar 2 was used for quality assessment. Risk of bias was evaluated with the Newcastle Ottawa Quality assessment tool. Data of the studies were visually presented in tables using SPIDER tool. Results Thirty-five publications, representing 3436 patients, met the search criteria and were included in the analysis. The selected reports concern: motion analysis (n = 17), urology (n = 12), gynecology (n = 1), other specialties (n = 1), training (n = 3), and tissue retraction (n = 1). Precision for surgical tools detection varied from 76.0% to 90.6%. Mean absolute error on prediction of urinary continence after robot-assisted radical prostatectomy (RARP) ranged from 85.9 to 134.7 days. Accuracy on prediction of length of stay after RARP was 88.5%. Accuracy on recognition of the next surgical task during robot-assisted partial nephrectomy (RAPN) achieved 75.7%. Conclusion The reviewed studies were of low quality. The findings are limited by the small size of the datasets. Comparison between studies on the same topic was restricted due to algorithms and datasets heterogeneity. There is no proof that currently AI can identify the critical tasks of RAS operations, which determine patient outcome. There is an urgent need for studies on large datasets and external validation of the AI algorithms used. Furthermore, the results should be transparent and meaningful to surgeons, enabling them to inform patients in layman’s words. Registration Review Registry Unique Identifying Number: reviewregistry1225. Highlights Several limitations and technical issues were found in the reviewed published studies. There is no proof that currently AI can recognize critical tasks of RAS operations. Studies on large datasets together with external validation of AI algorithms are needed. More transparent results are needed, which are meaningful to surgeons in future publications on AI. A glossary and an appendix for better understanding of the AI terms have been added.

Integrity signals

Registry

Crossref · 10.1016/j.ijsu.2021.106151

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Moglia, A., Georgiou, K., Georgiou, E., Satava, R. M., & Cuschieri, A.
Affiliations
  • University of Pisa (IT)
  • National and Kapodistrian University of Athens (GR)
  • University of Washington Medical Center (US)
  • Scuola Superiore Sant'Anna (IT)
Corresponding author
Moglia, Andrea
Venue
International Journal of Surgery
Published
2021-11
Volume
95
Pages
106151
ISSN
  • 1743-9159 (ISSN-L)
  • 1743-9191
OpenAlex
W3211048356
Cited by
236
References
7
Citations by year
2026: 53 · 2025: 82 · 2024: 51 · 2023: 39 · 2022: 11
FWCI
6.08
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Surgery (publishedVersion)
  • PubMed (publishedVersion)
  • Discovery Research Portal (University of Dundee) (submittedVersion)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
Keywords
artificial intelligence, robotic surgery, patient safety, robot-assisted radical prostatectomy, length of stay prediction, robot-assisted partial nephrectomy, surgical tool detection, surgical training, gynecologic surgery, tissue retraction, urologic surgery
MeSH terms
Artificial Intelligence, Humans, Male, Laparoscopy, Prostate, Prostatectomy, Robotic Surgical Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review