Validation of a Deep Learning Algorithm for the Detection of Malignant Pulmonary Nodules in Chest Radiographs
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Importance: The improvement of pulmonary nodule detection, which is a challenging task when using chest radiographs, may help to elevate the role of chest radiographs for the diagnosis of lung cancer. Objective: To assess the performance of a deep learning-based nodule detection algorithm for the detection of lung cancer on chest radiographs from participants in the National Lung Screening Trial (NLST). Design, Setting, and Participants: This diagnostic study used data from participants in the NLST ro assess the performance of a deep learning-based artificial intelligence (AI) algorithm for the detection of pulmonary nodules and lung cancer on chest radiographs using separate training (in-house) and validation (NLST) data sets. Baseline (T0) posteroanterior chest radiographs from 5485 participants (full T0 data set) were used to assess lung cancer detection performance, and a subset of 577 of these images (nodule data set) were used to assess nodule detection performance. Participants aged 55 to 74 years who currently or formerly (ie, quit within the past 15 years) smoked cigarettes for 30 pack-years or more were enrolled in the NLST at 23 US centers between August 2002 and April 2004. Information on lung cancer diagnoses was collected through December 31, 2009. Analyses were performed between August 20, 2019, and February 14, 2020. Exposures: Abnormality scores produced by the AI algorithm. Main Outcomes and Measures: The performance of an AI algorithm for the detection of lung nodules and lung cancer on radiographs, with lung cancer incidence and mortality as primary end points. Results: A total of 5485 participants (mean [SD] age, 61.7 [5.0] years; 3030 men [55.2%]) were included, with a median follow-up duration of 6.5 years (interquartile range, 6.1-6.9 years). For the nodule data set, the sensitivity and specificity of the AI algorithm for the detection of pulmonary nodules were 86.2% (95% CI, 77.8%-94.6%) and 85.0% (95% CI, 81.9%-88.1%), respectively. For the detection of all cancers, the sensitivity was 75.0% (95% CI, 62.8%-87.2%), the specificity was 83.3% (95% CI, 82.3%-84.3%), the positive predictive value was 3.8% (95% CI, 2.6%-5.0%), and the negative predictive value was 99.8% (95% CI, 99.6%-99.9%). For the detection of malignant pulmonary nodules in all images of the full T0 data set, the sensitivity was 94.1% (95% CI, 86.2%-100.0%), the specificity was 83.3% (95% CI, 82.3%-84.3%), the positive predictive value was 3.4% (95% CI, 2.2%-4.5%), and the negative predictive value was 100.0% (95% CI, 99.9%-100.0%). In digital radiographs of the nodule data set, the AI algorithm had higher sensitivity (96.0% [95% CI, 88.3%-100.0%] vs 88.0% [95% CI, 75.3%-100.0%]; P = .32) and higher specificity (93.2% [95% CI, 89.9%-96.5%] vs 82.8% [95% CI, 77.8%-87.8%]; P = .001) for nodule detection compared with the NLST radiologists. For malignant pulmonary nodule detection on digital radiographs of the full T0 data set, the sensitivity of the AI algorithm was higher (100.0% [95% CI, 100.0%-100.0%] vs 94.1% [95% CI, 82.9%-100.0%]; P = .32) compared with the NLST radiologists, and the specificity (90.9% [95% CI, 89.6%-92.1%] vs 91.0% [95% CI, 89.7%-92.2%]; P = .91), positive predictive value (8.2% [95% CI, 4.4%-11.9%] vs 7.8% [95% CI, 4.1%-11.5%]; P = .65), and negative predictive value (100.0% [95% CI, 100.0%-100.0%] vs 99.9% [95% CI, 99.8%-100.0%]; P = .32) were similar to those of NLST radiologists. Conclusions and Relevance: In this study, the AI algorithm performed better than NLST radiologists for the detection of pulmonary nodules on digital radiographs. When used as a second reader, the AI algorithm may help to detect lung cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial
de Koning, H. J., van der Aalst, C. M., de Jong, P. A., Scholten, E. T., Nackaerts, K., Heuvelmans, M. A., Lammers, J.-W. J., Weenink, C., Yousaf-Khan, U., Horeweg, N., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1911793 · Cited by 3,624
Rajpurkar, P., Irvin, J., Ball, R. L., Zhu, K., Yang, B., Mehta, H., Duan, T., Ding, D., Bagul, A., Langlotz, C. P., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002686 · Cited by 1,449
AutoAugment: Learning Augmentation Policies from Data
Cubuk, E. D., Zoph, B., Mane, D., Vasudevan, V., & Le, Q. V. (2018) · arXiv · doi:10.48550/arxiv.1805.09501 · Cited by 1,106
Nam, J. G., Park, S., Hwang, E. J., Lee, J. H., Jin, K.-N., Lim, K. Y., Vu, T. H., Sohn, J. H., Hwang, S., Goo, J. M., et al. (2019) · Radiology · doi:10.1148/radiol.2018180237 · Cited by 539
Hwang, E. J., Park, S., Jin, K.-N., Kim, J. I., Choi, S. Y., Lee, J. H., Goo, J. M., Aum, J., Yim, J.-J., Cohen, J. G., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.1095 · Cited by 447
Majkowska, A., Mittal, S., Steiner, D. F., Reicher, J. J., McKinney, S. M., Duggan, G. E., Eswaran, K., Cameron Chen, P.-H., Liu, Y., Kalidindi, S. R., et al. (2020) · Radiology · doi:10.1148/radiol.2019191293 · Cited by 277
Sim, Y., Chung, M. J., Kotter, E., Yune, S., Kim, M., Do, S., Han, K., Kim, H., Yang, S., Lee, D.-J., et al. (2020) · Radiology · doi:10.1148/radiol.2019182465 · Cited by 248
Deep Learning for Chest Radiograph Diagnosis in the Emergency Department
Hwang, E. J., Nam, J. G., Lim, W. H., Park, S. J., Jeong, Y. S., Kang, J. H., Hong, E. K., Kim, T. M., Goo, J. M., Park, S., et al. (2019) · Radiology · doi:10.1148/radiol.2019191225 · Cited by 164
Self-citation
Cited by
Deep learning for chest X-ray analysis: A survey
Çallı, E., Sogancioglu, E., van Ginneken, B., van Leeuwen, K. G., & Murphy, K. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102125 · Cited by 506
Huang, S., Yang, J., Shen, N., Xu, Q., & Zhao, Q. (2023) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2023.01.006 · Cited by 317
Novel research and future prospects of artificial intelligence in cancer diagnosis and treatment
Zhang, C., Xu, J., Tang, R., Yang, J., Wang, W., Yu, X., & Shi, S. (2023) · Journal of Hematology & Oncology · doi:10.1186/s13045-023-01514-5 · Cited by 148
Homayounieh, F., Digumarthy, S., Ebrahimian, S., Rueckel, J., Hoppe, B. F., Sabel, B. O., Conjeti, S., Ridder, K., Sistermanns, M., Wang, L., et al. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.41096 · Cited by 113
Self-citationLiu, P.-R., Zhang, J.-Y., Xue, M.-D., Duan, Y.-Y., Hu, J.-L., Liu, S.-X., Xie, Y., Wang, H.-L., Wang, J.-W., Huo, T.-T., et al. (2021) · Current Medical Science · doi:10.1007/s11596-021-2501-4 · Cited by 45
Metadata
- Authors
- Yoo, H., Kim, K. H., Singh, R., Digumarthy, S. R., & Kalra, M. K.
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2020-09-24
- Volume
- 3
- Issue
- 9
- Pages
- e2017135
- ISSN
- 2574-3805 (ISSN-L)
- OpenAlex
- W3088065065
- Cited by
- 122
- References
- 10
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.