Artificial Intelligence for Screening of Multiple Retinal and Optic Nerve Diseases
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Importance: The lack of experienced ophthalmologists limits the early diagnosis of retinal diseases. Artificial intelligence can be an efficient real-time way for screening retinal diseases. Objective: To develop and prospectively validate a deep learning (DL) algorithm that, based on ocular fundus images, recognizes numerous retinal diseases simultaneously in clinical practice. Design, Setting, and Participants: This multicenter, diagnostic study at 65 public medical screening centers and hospitals in 19 Chinese provinces included individuals attending annual routine medical examinations and participants of population-based and community-based studies. Exposures: Based on 120 002 ocular fundus photographs, the Retinal Artificial Intelligence Diagnosis System (RAIDS) was developed to identify 10 retinal diseases. RAIDS was validated in a prospective collected data set, and the performance between RAIDS and ophthalmologists was compared in the data sets of the population-based Beijing Eye Study and the community-based Kailuan Eye Study. Main Outcomes and Measures: The performance of each classifier included sensitivity, specificity, accuracy, F1 score, and Cohen κ score. Results: In the prospective validation data set of 208 758 images collected from 110 784 individuals (median [range] age, 42 [8-87] years; 115 443 [55.3%] female), RAIDS achieved a sensitivity of 89.8% (95% CI, 89.5%-90.1%) to detect any of 10 retinal diseases. RAIDS differentiated 10 retinal diseases with accuracies ranging from 95.3% to 99.9%, without marked differences between medical screening centers and geographical regions in China. Compared with retinal specialists, RAIDS achieved a higher sensitivity for detection of any retinal abnormality (RAIDS, 91.7% [95% CI, 90.6%-92.8%]; certified ophthalmologists, 83.7% [95% CI, 82.1%-85.1%]; junior retinal specialists, 86.4% [95% CI, 84.9%-87.7%]; and senior retinal specialists, 88.5% [95% CI, 87.1%-89.8%]). RAIDS reached a superior or similar diagnostic sensitivity compared with senior retinal specialists in the detection of 7 of 10 retinal diseases (ie, referral diabetic retinopathy, referral possible glaucoma, macular hole, epiretinal macular membrane, hypertensive retinopathy, myelinated fibers, and retinitis pigmentosa). It achieved a performance comparable with the performance by certified ophthalmologists in 2 diseases (ie, age-related macular degeneration and retinal vein occlusion). Compared with ophthalmologists, RAIDS needed 96% to 97% less time for the image assessment. Conclusions and Relevance: In this diagnostic study, the DL system was associated with accurately distinguishing 10 retinal diseases in real time. This technology may help overcome the lack of experienced ophthalmologists in underdeveloped areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
YOLOv3: An Incremental Improvement
Redmon, J., & Farhadi, A. (2018) · arXiv · doi:10.48550/arxiv.1804.02767 · Cited by 17,141
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Steinmetz, J. D., Bourne, R. R. A., Briant, P. S., Flaxman, S. R., Taylor, H. R. B., Jonas, J. B., Abdoli, A. A., Abrha, W. A., Abualhasan, A., Abu-Gharbieh, E. G., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30489-7 · Cited by 3,189
Self-citationTing, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Self-citationGuidelines on Diabetic Eye Care
Wong, T. Y., Sun, J., Kawasaki, R., Ruamviboonsuk, P., Gupta, N., Lansingh, V. C., Maia, M., Mathenge, W., Moreker, S., Muqit, M. M. K., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.04.007 · Cited by 839
Li, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657
Li, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
Lee, A. Y., Yanagihara, R. T., Lee, C. S., Blazes, M., Jung, H. C., Chee, Y. E., Gencarella, M. D., Gee, H., Maa, A. Y., Cockerham, G. C., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1877 · Cited by 194
Cited by
Li, Q., & Qin, Y. (2023) · BMC Medical Education · doi:10.1186/s12909-023-04700-8 · Cited by 131
Medical education and physician training in the era of artificial intelligence
Xu, Y., Jiang, Z., Ting, D. S. W., Kow, A. W. C., Bello, F., Car, J., Tham, Y.-C., & Wong, T. Y. (2024) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2023-203 · Cited by 76
Yang, Q., Bee, Y. M., Lim, C. C., Sabanayagam, C., Yim-Lui Cheung, C., Wong, T. Y., Ting, D. S. W., Lim, L.-L., Li, H., He, M., et al. (2025) · eClinicalMedicine · doi:10.1016/j.eclinm.2025.103089 · Cited by 38
“10 For individuals with diabetes, international guidelines recommend regular screening for diabetic retinopathy, which is usually performed by telemedicine based digital fundus photographic screening.”
Self-citationWang, Z., Li, Z., Li, K., Mu, S., Zhou, X., & Di, Y. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1197783 · Cited by 27
Self-citation
Metadata
- Authors
- Dong, L., He, W., Zhang, R., Ge, Z., Wang, Y. X., Zhou, J., Xu, J., Shao, L., Wang, Q., Yan, Y., Xie, Y., Fang, L., Wang, H., Wang, Y., Zhu, X., Wang, J., Zhang, C., Wang, H., Wang, Y., Chen, R., Wan, Q., Yang, J., Zhou, W., Li, H., Yao, X., Yang, Z., Xiong, J., Wang, X., Huang, Y., Chen, Y., Wang, Z., Rong, C., Gao, J., Zhang, H., Wu, S., Jonas, J. B., & Wei, W. B.
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2022-05-03
- Volume
- 5
- Issue
- 5
- Pages
- e229960
- ISSN
- 2574-3805 (ISSN-L)
- OpenAlex
- W4225329856
- Cited by
- 157
- References
- 10
- FWCI
- 15.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Intelligence for Screening of Multiple Retinal and Optic Nerve Diseases. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2022.9960
- The paper
- Dong, L., He, W., Zhang, R., Ge, Z., Wang, Y. X., Zhou, J., Xu, J., Shao, L., Wang, Q., Yan, Y., Xie, Y., Fang, L., Wang, H., Wang, Y., Zhu, X., Wang, J., Zhang, C., Wang, H., Wang, Y., . . . Wei, W. B. (2022). Artificial Intelligence for Screening of Multiple Retinal and Optic Nerve Diseases. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2022.9960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.