Development of Expert-Level Automated Detection of Epileptiform Discharges During Electroencephalogram Interpretation

Open access
Jing, Jin, Sun, Haoqi, Kim, Jennifer A., Herlopian, Aline, Karakis, Ioannis, Ng, Marcus, Halford, Jonathan J., Maus, Douglas, Chan, Fonda, Dolatshahi, Marjan, Muniz, Carlos, Chu, Catherine, Sacca, Valeria, Pathmanathan, Jay, Ge, Wendong, Dauwels, Justin, Lam, Alice, Cole, Andrew J., Cash, Sydney S., Westover, M. Brandon · 2020 · JAMA Neurology
Cited by 190

The DOI matches its Crossref record.

Abstract

Importance: Interictal epileptiform discharges (IEDs) in electroencephalograms (EEGs) are a biomarker of epilepsy, seizure risk, and clinical decline. However, there is a scarcity of experts qualified to interpret EEG results. Prior attempts to automate IED detection have been limited by small samples and have not demonstrated expert-level performance. There is a need for a validated automated method to detect IEDs with expert-level reliability. Objective: To develop and validate a computer algorithm with the ability to identify IEDs as reliably as experts and classify an EEG recording as containing IEDs vs no IEDs. Design, Setting, and Participants: A total of 9571 scalp EEG records with and without IEDs were used to train a deep neural network (SpikeNet) to perform IED detection. Independent training and testing data sets were generated from 13 262 IED candidates, independently annotated by 8 fellowship-trained clinical neurophysiologists, and 8520 EEG records containing no IEDs based on clinical EEG reports. Using the estimated spike probability, a classifier designating the whole EEG recording as positive or negative was also built. Main Outcomes and Measures: SpikeNet accuracy, sensitivity, and specificity compared with fellowship-trained neurophysiology experts for identifying IEDs and classifying EEGs as positive or negative or negative for IEDs. Statistical performance was assessed via calibration error and area under the receiver operating characteristic curve (AUC). All performance statistics were estimated using 10-fold cross-validation. Results: SpikeNet surpassed both expert interpretation and an industry standard commercial IED detector, based on calibration error (SpikeNet, 0.041; 95% CI, 0.033-0.049; vs industry standard, 0.066; 95% CI, 0.060-0.078; vs experts, mean, 0.183; range, 0.081-0.364) and binary classification performance based on AUC (SpikeNet, 0.980; 95% CI, 0.977-0.984; vs industry standard, 0.882; 95% CI, 0.872-0.893). Whole EEG classification had a mean calibration error of 0.126 (range, 0.109-0.1444) vs experts (mean, 0.197; range, 0.099-0.372) and AUC of 0.847 (95% CI, 0.830-0.865). Conclusions and Relevance: In this study, SpikeNet automatically detected IEDs and classified whole EEGs as IED-positive or IED-negative. This may be the first time an algorithm has been shown to exceed expert performance for IED detection in a representative sample of EEGs and may thus be a valuable tool for expedited review of EEGs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaneurol.2019.3485

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Jing, J., Sun, H., Kim, J. A., Herlopian, A., Karakis, I., Ng, M., Halford, J. J., Maus, D., Chan, F., Dolatshahi, M., Muniz, C., Chu, C., Sacca, V., Pathmanathan, J., Ge, W., Dauwels, J., Lam, A., Cole, A. J., Cash, S. S., & Westover, M. B.
Venue
JAMA Neurology
Published
2020-01-01
Volume
77
Issue
1
Pages
103
ISSN
2168-6149 (ISSN-L)
OpenAlex
W2980967712
Cited by
190
References
0
FWCI
8.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of Expert-Level Automated Detection of Epileptiform Discharges During Electroencephalogram Interpretation. https://app.cochat.ai/papers/10.1001/jamaneurol.2019.3485
The paper
Jing, J., Sun, H., Kim, J. A., Herlopian, A., Karakis, I., Ng, M., Halford, J. J., Maus, D., Chan, F., Dolatshahi, M., Muniz, C., Chu, C., Sacca, V., Pathmanathan, J., Ge, W., Dauwels, J., Lam, A., Cole, A. J., Cash, S. S., & Westover, M. B. (2020). Development of Expert-Level Automated Detection of Epileptiform Discharges During Electroencephalogram Interpretation. JAMA Neurology. https://doi.org/10.1001/jamaneurol.2019.3485

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.