Association of Digital Breast Tomosynthesis vs Digital Mammography With Cancer Detection and Recall Rates by Age and Breast Density
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Breast cancer screening examinations using digital breast tomosynthesis (DBT) has been shown to be associated with decreased false-positive test results and increased breast cancer detection compared with digital mammography (DM). Little is known regarding the size and stage of breast cancer types detected and their association with age and breast density. OBJECTIVE: To determine whether screening examinations using DBT detect breast cancers that are associated with an improved prognosis and to compare the detection rates by patient age and breast density. DESIGN, SETTING, AND PARTICIPANTS: This retrospective analysis of prospective cohort data from 3 research centers in the Population-based Research Optimizing Screening Through Personalized Regimens (PROSPR) consortium included data of women aged 40 to 74 years who underwent screening examinations using DM and DBT from January 1, 2011, through September 30, 2014. Statistical analysis was performed from November 8, 2017, to August 14, 2018. EXPOSURES: Use of DBT as a supplement to DM at breast cancer screening examination. MAIN OUTCOMES AND MEASURES: Recall rate, cancer detection rate, positive predictive value, biopsy rate, and distribution of invasive cancer subtypes. RESULTS: Among 96 269 women (mean [SD] patient age for all examinations, 55.9 [9.0] years), patient age was 56.4 (9.0) years for DM and 54.6 (8.9) years for DBT. Of 180 340 breast cancer screening examinations, 129 369 examinations (71.7%) used DM and 50 971 examinations (28.3%) used DBT. Screening examination with DBT (73 of 99 women [73.7%]) was associated with the detection of smaller, more often node-negative, HER2-negative, invasive cancers compared with DM (276 of 422 women [65.4%]). Screening examination with DBT was also associated with lower recall (odds ratio, 0.64; 95% CI, 0.57-0.72; P < .001) and higher cancer detection (odds ratio, 1.41; 95% CI, 1.05-1.89; P = .02) compared with DM for all age groups even when stratified by breast density. The largest increase in cancer detection rate and the greatest shift toward smaller, node-negative invasive cancers detected with DBT was for women aged 40 to 49 years. For women aged 40 to 49 years with nondense breasts, the cancer detection rate for examinations using DBT was 1.70 per 1000 women higher compared with the rate using DM; for women with dense breasts, the cancer detection rate was 2.27 per 1000 women higher for DBT. For these younger women, screening with DBT was associated with only 7 of 28 breast cancers (25.0%) categorized as poor prognosis compared with 19 of 47 breast cancers (40.4%) when screening with DM. CONCLUSIONS AND RELEVANCE: The findings suggest that screening with DBT is associated with increased specificity and an increased proportion of breast cancers detected with better prognosis compared with DM. In the subgroup of women aged 40 to 49 years, routine DBT screening may have a favorable risk-benefit ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012
Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Friedewald, S. M., Rafferty, E. A., Rose, S. L., Durand, M. A., Plecha, D. M., Greenberg, J. S., Hayes, M. K., Copit, D. S., Carlson, K. L., Cink, T. M., et al. (2014) · JAMA · doi:10.1001/jama.2014.6095 · Cited by 851
Self-citationCiatto, S., Houssami, N., Bernardi, D., Caumo, F., Pellegrini, M., Brunelli, S., Tuttobene, P., Bricolo, P., Fantò, C., Valentini, M., et al. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70134-7 · Cited by 838 · cited 2×
“Invasive disease was further classified by hormone receptor status (positive or negative), HER2 status (positive or negative), nodal status (positive or negative), tumor size (<1 cm, 1-2 cm, or >2 cm), and tumor grade (1-3).”
BackgroundMethodImplementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Plevritis, S. K., Munoz, D., Kurian, A. W., Stout, N. K., Alagoz, O., Near, A. M., Lee, S. J., van den Broek, J. J., Huang, X., Schechter, C. B., et al. (2018) · JAMA · doi:10.1001/jama.2017.19130 · Cited by 302
Self-citationMarinovich, M. L., Hunter, K. E., Macaskill, P., & Houssami, N. (2018) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy121 · Cited by 249 · cited 2×
“Invasive disease was further classified by hormone receptor status (positive or negative), HER2 status (positive or negative), nodal status (positive or negative), tumor size (<1 cm, 1-2 cm, or >2 cm), and tumor grade (1-3).”
BackgroundMethodConant, E. F., Beaber, E. F., Sprague, B. L., Herschorn, S. D., Weaver, D. L., Onega, T., Tosteson, A. N. A., McCarthy, A. M., Poplack, S. P., Haas, J. S., et al. (2016) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-3695-1 · Cited by 184
Self-citationMcDonald, E. S., McCarthy, A. M., Akhtar, A. L., Synnestvedt, M. B., Schnall, M. D., & Conant, E. F. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14406 · Cited by 62
Self-citationBreast Cancer With a Poor Prognosis Diagnosed After Screening Mammography With Negative Results
McCarthy, A. M., Barlow, W. E., Conant, E. F., Haas, J. S., Li, C. I., Sprague, B. L., & Armstrong, K. (2018) · JAMA Oncology · doi:10.1001/jamaoncol.2018.0352 · Cited by 30
Self-citation
Cited by
ESO–ESMO fifth international consensus guidelines for breast cancer in young women (BCY5)
Paluch-Shimon, S., Cardoso, F., Partridge, A. H., Abulkhair, O., Azim, H. A., Bianchi-Micheli, G., Cardoso, M. J., Curigliano, G., Gelmon, K. A., Gentilini, O., et al. (2022) · Annals of Oncology · doi:10.1016/j.annonc.2022.07.007 · Cited by 237
Pötsch, N., Vatteroni, G., Clauser, P., Helbich, T. H., & Baltzer, P. A. T. (2022) · Radiology · doi:10.1148/radiol.212530 · Cited by 162
Novel research and future prospects of artificial intelligence in cancer diagnosis and treatment
Zhang, C., Xu, J., Tang, R., Yang, J., Wang, W., Yu, X., & Shi, S. (2023) · Journal of Hematology & Oncology · doi:10.1186/s13045-023-01514-5 · Cited by 148
Metadata
- Authors
- Conant, E. F., Barlow, W. E., Herschorn, S. D., Weaver, D. L., Beaber, E. F., Tosteson, A. N. A., Haas, J. S., Lowry, K. P., Stout, N. K., Trentham-Dietz, A., diFlorio-Alexander, R. M., Li, C. I., Schnall, M. D., Onega, T., Sprague, B. L., & for the Population-based Research Optimizing Screening Through Personalized Regimen (PROSPR) Consortium
- Venue
- JAMA Oncology
- Publisher
- American Medical Association (AMA)
- Published
- 2019-05-01
- Volume
- 5
- Issue
- 5
- Pages
- 635
- ISSN
- 2374-2437 (ISSN-L)
- OpenAlex
- W2918601053
- Cited by
- 217
- References
- 12
- FWCI
- 22.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.