The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall
Open accessAbstract
Background: Tomosynthesis approximates a 3D mammogram of the breast, reducing parenchymal overlap that masks cancers or creates false "lesions" on 2D mammography, and potentially enabling more accurate detection of breast cancer. We compared breast cancer screening detection and recall in asymptomatic women for tomosynthesis vs 2D mammography. Methods: A systematic review and random effects meta-analysis were undertaken. Electronic databases (2009-July 2017) were searched for studies comparing tomosynthesis and 2D mammography in asymptomatic women who attended population breast cancer screening and reporting cancer detection rate (CDR) and recall rate. All statistical tests were two-sided. Results: Seventeen studies (1 009 790 participants) were included from 413 citations. The pooled incremental CDR for tomosynthesis was 1.6 cancers per 1000 screens (95% confidence interval [CI] = 1.1 to 2.0, P < .001, I2 = 36.9%). Incremental CDR was statistically significantly higher for European/Scandinavian studies, all using a "paired" design where women had both tests (2.4 per 1000 screens, 95% CI = 1.9 to 2.9, P < .001, I2 = 0.0%) compared with US ("unpaired") studies (1.1 per 1000 screens, 95% CI = 0.8 to 1.5, P < .001, I2 = 0.0%; P < .001 between strata). The recall rate for tomosynthesis was statistically significantly lower than for 2D mammography (pooled absolute reduction = -2.2%, 95% CI = -3.0 to -1.4, P < .001, I2 = 98.2%). Stratified analyses showed a decrease in US studies (pooled difference in recall rate = -2.9%, 95% CI = -3.5 to -2.4, P < .001, I2 = 92.9%) but not European/Scandinavian studies (0.5% increase in recall, 95% CI = -0.1 to 1.2, P = .12, I2 = 93.5%; P < .001 between strata). Results were similar in sensitivity analyses excluding studies with overlapping cohorts. Conclusions: Tomosynthesis improves CDR and reduces recall; however, effects are dependent on screening setting, with greater improvement in CDR in European/Scandinavian studies (biennial screening) and reduction in recall in US studies with high baseline recall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 1×
“In accordance with methodology recommended by the Cochrane Collaboration (11), the potential for publication bias was not formally assessed as the methods developed for randomized controlled trials (ie, tests of funnel plot asymmetry) are not appropriate for studies of screening and diagnostic tests (12).”
MethodSelf-citationCochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy
(2023) · doi:10.1002/9781119756194 · Cited by 757
Cited by
Harbeck, N., Penault-Llorca, F., Cortes, J., Gnant, M., Houssami, N., Poortmans, P., Ruddy, K., Tsang, J., & Cardoso, F. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0111-2 · Cited by 3,024
Self-citationLoibl, S., Poortmans, P., Morrow, M., Denkert, C., & Curigliano, G. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32381-3 · Cited by 1,648
Breast Cancer Screening for Women at Higher-Than-Average Risk: Updated Recommendations From the ACR
Monticciolo, D. L., Newell, M. S., Moy, L., Lee, C. S., & Destounis, S. V. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.04.002 · Cited by 290
Omics Technologies Improving Breast Cancer Research and Diagnostics
Orsini, A., Diquigiovanni, C., & Bonora, E. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241612690 · Cited by 52
Metadata
- Authors
- Marinovich, M. L., Hunter, K. E., Macaskill, P., & Houssami, N.
- Venue
- JNCI: Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-08-09
- Volume
- 110
- Issue
- 9
- Pages
- 942-949
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2885655595
- Cited by
- 249
- References
- 3
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall. https://app.cochat.ai/papers/10.1093/jnci/djy121
- The paper
- Marinovich, M. L., Hunter, K. E., Macaskill, P., & Houssami, N. (2018). Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall. JNCI: Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/djy121
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.