Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based Fieldwork
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Visual acuity is the most frequently performed measure of visual function in clinical practice and most people worldwide living with visual impairment are living in low- and middle-income countries. OBJECTIVE: To design and validate a smartphone-based visual acuity test that is not dependent on familiarity with symbols or letters commonly used in the English language. DESIGN, SETTING, AND PARTICIPANTS: Validation study conducted from December 11, 2013, to March 4, 2014, comparing results from smartphone-based Peek Acuity to Snellen acuity (clinical normal) charts and the Early Treatment Diabetic Retinopathy Study (ETDRS) logMAR chart (reference standard). This study was nested within the 6-year follow-up of the Nakuru Eye Disease Cohort in central Kenya and included 300 adults aged 55 years and older recruited consecutively. MAIN OUTCOMES AND MEASURES: Outcome measures were monocular logMAR visual acuity scores for each test: ETDRS chart logMAR, Snellen acuity, and Peek Acuity. Peek Acuity was compared, in terms of test-retest variability and measurement time, with the Snellen acuity and ETDRS logMAR charts in participants' homes and temporary clinic settings in rural Kenya in 2013 and 2014. RESULTS: The 95% CI limits for test-retest variability of smartphone acuity data were ±0.033 logMAR. The mean differences between the smartphone-based test and the ETDRS chart and the smartphone-based test and Snellen acuity data were 0.07 (95% CI, 0.05-0.09) and 0.08 (95% CI, 0.06-0.10) logMAR, respectively, indicating that smartphone-based test acuities agreed well with those of the ETDRS and Snellen charts. The agreement of Peek Acuity and the ETDRS chart was greater than the Snellen chart with the ETDRS chart (95% CI, 0.05-0.10; P = .08). The local Kenyan community health care workers readily accepted the Peek Acuity smartphone test; it required minimal training and took no longer than the Snellen test (77 seconds vs 82 seconds; 95% CI, 71-84 seconds vs 73-91 seconds, respectively; P = .13). CONCLUSIONS AND RELEVANCE: The study demonstrated that the Peek Acuity smartphone test is capable of accurate and repeatable acuity measurements consistent with published data on the test-retest variability of acuities measured using 5-letter-per-line retroilluminated logMAR charts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cook, R. J., Dickens, B. M., & Fathalla, M. F. (2003) · Reproductive Health and Human Rights · doi:10.1093/acprof:oso/9780199241323.003.0025 · Cited by 10,769
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Global estimates of visual impairment: 2010
Pascolini, D., & Mariotti, S. P. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300539 · Cited by 3,763
(2014) · Journal of the Korean Medical Association · doi:10.5124/jkma.2014.57.11.899 · Cited by 2,566
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
New Design Principles for Visual Acuity Letter Charts
Bailey, I. L., & Lovie, J. E. (1976) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1976.tb02218.x · Cited by 1,407
Proper Method for Calculating Average Visual Acuity
Holladay, J. T. (1997) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19970701-16 · Cited by 1,090
Labrique, A. B., Vasudevan, L., Kochi, E., Fabricant, R., & Mehl, G. (2013) · Global Health: Science and Practice · doi:10.9745/ghsp-d-13-00031 · Cited by 601
Kaiser, P. K. (2009) · PubMed Central · Cited by 315
How Sensitive to Clinical Change are ETDRS logMAR Visual Acuity Measurements?
Rosser, D. A., Cousens, S. N., Murdoch, I. E., Fitzke, F. W., & Laidlaw, D. A. H. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1100 · Cited by 264
On the statistical reliability of letter-chart visual acuity measurements.
Arditi, A. R., & Cagenello, R. (1993) · PubMed · Cited by 239
Mobile health use in low- and high-income countries: an overview of the peer-reviewed literature
Bastawrous, A., & Armstrong, M. J. (2013) · Journal of the Royal Society of Medicine · doi:10.1177/0141076812472620 · Cited by 236
Self-citationLittle, A., Medhanyie, A., Yebyo, H., Spigt, M., Dinant, G.-J., & Blanco, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077563 · Cited by 107
Bastawrous, A. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.11.014 · Cited by 94
Self-citationPerera, C. M., Chakrabarti, R., Islam, A. F. M., & Crowston, J. G. (2015) · Eye · doi:10.1038/eye.2015.60 · Cited by 81
Laidlaw, D. A. H., Abbott, A., & Rosser, D. A. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.10.1232 · Cited by 78
Effectiveness of a smartphone application for testing near visual acuity
Tofigh, S., Shortridge, E., Elkeeb, A., & Godley, B. F. (2015) · Eye · doi:10.1038/eye.2015.138 · Cited by 74
Study of diagnostic accord between general practitioners and an ophthalmologist.
Sheldrick, J. H., Vernon, S. A., & Wilson, A. (1992) · BMJ · doi:10.1136/bmj.304.6834.1096 · Cited by 62
Bastawrous, A., Cheeseman, R., & Kumar, A. (2012) · Eye · doi:10.1038/eye.2012.6 · Cited by 41
Self-citationHow apps are changing family medicine.
Lippman, H. (2013) · PubMed · Cited by 37
Application of smartphone cameras for detecting clinically active trachoma: Table 1
Bhosai, S. J., Amza, A., Beido, N., Bailey, R. L., Keenan, J. D., Gaynor, B. D., & Lietman, T. M. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-302050 · Cited by 37
The Nakuru Posterior Segment Eye Disease Study
Mathenge, W. C., Bastawrous, A., Foster, A., & Kuper, H. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.04.019 · Cited by 35
Self-citationShah, N., Dakin, S. C., Whitaker, H. L., & Anderson, R. S. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13340 · Cited by 32
Tamony, P., Holt, R. I. G., & Barnard, K. D. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815588559 · Cited by 30
Improving on ETDRS acuities: design and results for a computerised thresholding device
Rosser, D. A., Murdoch, I., Fitzke, F. W., & Laidlaw, D. A. H. (2003) · Eye · doi:10.1038/sj.eye.6700496 · Cited by 29
The Nakuru eye disease cohort study: methodology & rationale
Bastawrous, A., Mathenge, W. C., Pető, T., Weiss, H. A., Rono, H. K., Foster, A., Burton, M. J., & Kuper, H. (2014) · BMC Ophthalmology · doi:10.1186/1471-2415-14-60 · Cited by 27
Self-citationHempel, J. (2010) · Strategic Direction · doi:10.1108/sd.2010.05626bad.009 · Cited by 4
Cited by
The Lancet Global Health Commission on Global Eye Health: vision beyond 2020
Burton, M. J., Ramke, J., Marques, A. P., Bourne, R. R. A., Congdon, N., Jones, I., Ah Tong, B. A. M., Arunga, S., Bachani, D., Bascaran, C., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30488-5 · Cited by 1,624
Self-citationDigital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“Smartphone-based Peek Acuity distance visual acuity tests, conducted in the Nakuru Eye Disease Cohort in central Kenya showed accurate and repeatable measurements compared to gold-standard 5-letter-per-line retro-illuminated logMAR charts (Bastawrous et al., 2015).”
MethodDiabetes in sub-Saharan Africa: from clinical care to health policy
Atun, R., Davies, J. I., Gale, E. A. M., Bärnighausen, T., Beran, D., Kengne, A. P., Levitt, N. S., Mangugu, F. W., Nyirenda, M. J., Ogle, G. D., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30181-x · Cited by 543
Self-citationSevastopolsky, A. (2017) · Pattern Recognition and Image Analysis · doi:10.1134/s1054661817030269 · Cited by 432
Retinoblastoma, the visible CNS tumor: A review
Dimaras, H., & Corson, T. W. (2019) · Journal of Neuroscience Research · doi:10.1002/jnr.24213 · Cited by 178
“…like the Portable Eye Examination Kit (Peek), a smartphone application that allows users to recognize and detect eye conditions, including retinoblastoma (Bastawrous, 2016; Bastawrous et al., 2015; Lodhia, Karanja, Lees, & Bastawrous, 2016; Morjaria, Bastawrous, Murthy, Evans, & Gilbert, 2017).”
Metadata
- Authors
- Bastawrous, A., Rono, H. K., Livingstone, I. A. T., Weiss, H. A., Jordan, S., Kuper, H., & Burton, M. J.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2015-08-01
- Volume
- 133
- Issue
- 8
- Pages
- 930
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W1620526681
- Cited by
- 339
- References
- 28
- FWCI
- 13.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.