Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Visualization and interpretation of the optic nerve and retina are essential parts of most physical examinations. OBJECTIVE: To design and validate a smartphone-based retinal adapter enabling image capture and remote grading of the retina. DESIGN, SETTING, AND PARTICIPANTS: This validation study compared the grading of optic nerves from smartphone images with those of a digital retinal camera. Both image sets were independently graded at Moorfields Eye Hospital Reading Centre. Nested within the 6-year follow-up (January 7, 2013, to March 12, 2014) of the Nakuru Eye Disease Cohort in Kenya, 1460 adults (2920 eyes) 55 years and older were recruited consecutively from the study. A subset of 100 optic disc images from both methods were further used to validate a grading app for the optic nerves. Data analysis was performed April 7 to April 12, 2015. MAIN OUTCOMES AND MEASURES: Vertical cup-disc ratio for each test was compared in terms of agreement (Bland-Altman and weighted κ) and test-retest variability. RESULTS: A total of 2152 optic nerve images were available from both methods (also 371 from the reference camera but not the smartphone, 170 from the smartphone but not the reference camera, and 227 from neither the reference camera nor the smartphone). Bland-Altman analysis revealed a mean difference of 0.02 (95% CI, -0.21 to 0.17) and a weighted κ coefficient of 0.69 (excellent agreement). The grades of an experienced retinal photographer were compared with those of a lay photographer (no health care experience before the study), and no observable difference in image acquisition quality was found. CONCLUSIONS AND RELEVANCE: Nonclinical photographers using the low-cost smartphone adapter were able to acquire optic nerve images at a standard that enabled independent remote grading of the images comparable to those acquired using a desktop retinal camera operated by an ophthalmic assistant. The potential for task shifting and the detection of avoidable causes of blindness in the most at-risk communities makes this an attractive public health intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Resnikoff, S., Felch, W., Gauthier, T.-M., & Spivey, B. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-301378 · Cited by 405
TURNER, A. G., MAGNANI, R. J., & SHUAIB, M. (1996) · International Journal of Epidemiology · doi:10.1093/ije/25.1.198 · Cited by 248
Cited by
Seidman, G., & Atun, R. (2017) · Human Resources for Health · doi:10.1186/s12960-017-0200-9 · Cited by 231
Increasing access to eye care … there's an app for that. Peek: smartphone technology for eye health
Bastawrous, A. (2016) · International Journal of Epidemiology · doi:10.1093/ije/dyw086 · Cited by 21
“Peek Retina, a low-cost smartphone adapter, makes it possible to examine the retina using a smartphone.(5) The user only needs to be able to acquire images, and expert graders can review images remotely and action decisions without having to be away from busy eye units.”
BackgroundSelf-citationKatibeh, M., Sabbaghi, H., Kalantarion, M., Nikkhah, H., Mousavi, B., Beiranvand, R., Ahmadieh, H., & Kallestrup, P. (2020) · Ophthalmic Epidemiology · doi:10.1080/09286586.2020.1768552 · Cited by 13
Metadata
- Authors
- Bastawrous, A., Giardini, M. E., Bolster, N. M., Peto, T., Shah, N., Livingstone, I. A. T., Weiss, H. A., Hu, S., Rono, H., Kuper, H., & Burton, M.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2016-02-01
- Volume
- 134
- Issue
- 2
- Pages
- 151
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2180164968
- Cited by
- 169
- References
- 5
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2015.4625
- The paper
- Bastawrous, A., Giardini, M. E., Bolster, N. M., Peto, T., Shah, N., Livingstone, I. A. T., Weiss, H. A., Hu, S., Rono, H., Kuper, H., & Burton, M. (2016). Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2015.4625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.