Accuracy of a Popular Online Symptom Checker for Ophthalmic Diagnoses
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Importance: Because more patients are presenting with self-guided research of symptoms, it is important to assess the capabilities and limitations of these available health information tools. Objective: To determine the accuracy of the most popular online symptom checker for ophthalmic diagnoses. Design, Setting, and Participants: In a cross-sectional study, 42 validated clinical vignettes of ophthalmic symptoms were generated and distilled to their core presenting symptoms. Cases were entered into WebMD symptom checker by both medically trained and nonmedically trained personnel blinded to the diagnosis. Output from the symptom checker, including the number of symptoms, ranking and list of diagnoses, and triage urgency were recorded. The study was conducted on October 13, 2017. Analysis was performed between October 15, 2017, and April 30, 2018. Main Outcomes and Measures: Accuracy of the top 3 diagnoses generated by the online symptom checker. Results: The mean (SD) number of symptoms entered was 3.6 (1.6) (range, 1-8). The median (SD) number of diagnoses generated by the symptom checker was 26.8 (21.8) (range, 1-99). The primary diagnosis by the symptom checker was correct in 11 of 42 (26%; 95% CI, 12%-40%) cases. The correct diagnosis was included in the online symptom checker's top 3 diagnoses in 16 of 42 (38%; 95% CI, 25%-56%) cases. The correct diagnosis was not included in the symptom checker's list in 18 of 42 (43%; 95% CI, 32%-63%) cases. Triage urgency based on the top diagnosis was appropriate in 7 of 18 (39%; 95% CI, 14%-64%) emergent cases and 21 of 24 (88%; 95% CI, 73%-100%) nonemergent cases. Interuser variability for the correct diagnosis being in the top 3 listed was at least moderate (Cohen κ = 0.74; 95% CI, 0.54-0.95). Conclusions and Relevance: The most popular online symptom checker may arrive at the correct clinical diagnosis for ophthalmic conditions, but a substantial proportion of diagnoses may not be captured. These findings suggest that further research to reflect the real-life application of internet diagnostic resources is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of symptom checkers for self diagnosis and triage: audit study
Semigran, H. L., Linder, J. A., Gidengil, C., & Mehrotra, A. (2015) · BMJ · doi:10.1136/bmj.h3480 · Cited by 489
Internet Self-Diagnosis in Hand Surgery
Hageman, M. G. J. S., Anderson, J., Blok, R., Bossen, J. K. J., & Ring, D. (2015) · HAND · doi:10.1007/s11552-014-9707-x · Cited by 26
Cited by
Gilbert, S., Mehl, A., Baluch, A., Cawley, C., Challiner, J., Fraser, H., Millen, E., Montazeri, M., Multmeier, J., Pick, F., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-040269 · Cited by 183
“This includes a survey of users' technological literacy and user experience.”
Accuracy of online symptom checkers and the potential impact on service utilisation
Ceney, A., Tolond, S., Glowinski, A., Marks, B., Swift, S., & Palser, T. (2021) · PLOS ONE · doi:10.1371/journal.pone.0254088 · Cited by 125
Exploring and Promoting Diagnostic Transparency and Explainability in Online Symptom Checkers
Tsai, C.-H., You, Y., Gui, X., Kou, Y., & Carroll, J. M. (2021) · Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445101 · Cited by 86
“[3, 4, 11, 53, 62, 65]) have shown that diagnosis and triage advice provided by symptom checkers are often inaccurate.”
BackgroundHennemann, S., Kuhn, S., Witthöft, M., & Jungmann, S. M. (2022) · JMIR Mental Health · doi:10.2196/32832 · Cited by 31
“General diagnostic and triage advice of specific symptom checkers has been studied for a broad range of general and specialized health problems [26], for example, ophthalmologic [27] or viral diseases [28,29].”
BackgroundPeven, K., Wickham, A. P., Wilks, O., Kaplan, Y. C., Marhol, A., Ahmed, S., Bamford, R., Cunningham, A. C., Prentice, C., Meczner, A., et al. (2023) · JMIR mHealth and uHealth · doi:10.2196/46718 · Cited by 9
Metadata
- Authors
- Shen, C., Nguyen, M., Gregor, A., Isaza, G., & Beattie, A.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2019-06-01
- Volume
- 137
- Issue
- 6
- Pages
- 690
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2937791631
- Cited by
- 40
- References
- 2
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of a Popular Online Symptom Checker for Ophthalmic Diagnoses. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2019.0571
- The paper
- Shen, C., Nguyen, M., Gregor, A., Isaza, G., & Beattie, A. (2019). Accuracy of a Popular Online Symptom Checker for Ophthalmic Diagnoses. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2019.0571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.