The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Diagnostic Accuracy of Community-Based Diabetic Retinopathy Screening With an Offline Artificial Intelligence System on a Smartphone
Open accessAbstract
IMPORTANCE: Offline automated analysis of retinal images on a smartphone may be a cost-effective and scalable method of screening for diabetic retinopathy; however, to our knowledge, assessment of such an artificial intelligence (AI) system is lacking. OBJECTIVE: To evaluate the performance of Medios AI (Remidio), a proprietary, offline, smartphone-based, automated system of analysis of retinal images, to detect referable diabetic retinopathy (RDR) in images taken by a minimally trained health care worker with Remidio Non-Mydriatic Fundus on Phone, a smartphone-based, nonmydriatic retinal camera. Referable diabetic retinopathy is defined as any retinopathy more severe than mild diabetic retinopathy, with or without diabetic macular edema. DESIGN, SETTING, AND PARTICIPANTS: This prospective, cross-sectional, population-based study took place from August 2018 to September 2018. Patients with diabetes mellitus who visited various dispensaries administered by the Municipal Corporation of Greater Mumbai in Mumbai, India, on a particular day were included. INTERVENTIONS: Three fields of the fundus (the posterior pole, nasal, and temporal fields) were photographed. The images were analyzed by an ophthalmologist and the AI system. MAIN OUTCOMES AND MEASURES: To evaluate the sensitivity and specificity of the offline automated analysis system in detecting referable diabetic retinopathy on images taken on the smartphone-based, nonmydriatic retinal imaging system by a health worker. RESULTS: Of 255 patients seen in the dispensaries, 231 patients (90.6%) consented to diabetic retinopathy screening. The major reasons for not participating were unwillingness to wait for screening and the blurring of vision that would occur after dilation. Images from 18 patients were deemed ungradable by the ophthalmologist and hence were excluded. In the remaining participants (110 female patients [51.6%] and 103 male patients [48.4%]; mean [SD] age, 53.1 [10.3] years), the sensitivity and specificity of the offline AI system in diagnosing referable diabetic retinopathy were 100.0% (95% CI, 78.2%-100.0%) and 88.4% (95% CI, 83.2%-92.5%), respectively, and in diagnosing any diabetic retinopathy were 85.2% (95% CI, 66.3%-95.8%) and 92.0% (95% CI, 97.1%-95.4%), respectively, compared with ophthalmologist grading using the same images. CONCLUSIONS AND RELEVANCE: These pilot study results show promise in the use of an offline AI system in community screening for referable diabetic retinopathy with a smartphone-based fundus camera. The use of AI would enable screening for referable diabetic retinopathy in remote areas where services of an ophthalmologist are unavailable. This study was done on patients with diabetes who were visiting a dispensary that provides curative services to the population at the primary level. A study with a larger sample size may be needed to extend the results to general population screening, however.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Self-citationAbràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
Mydriasis and glaucoma: exploding the myth. A systematic review
Pandit, R. J., & Taylor, R. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00368.x · Cited by 94
Cited by
The Lancet Global Health Commission on Global Eye Health: vision beyond 2020
Burton, M. J., Ramke, J., Marques, A. P., Bourne, R. R. A., Congdon, N., Jones, I., Ah Tong, B. A. M., Arunga, S., Bachani, D., Bascaran, C., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30488-5 · Cited by 1,624
Role of Artificial Intelligence Applications in Real-Life Clinical Practice: Systematic Review
Yin, J., Ngiam, K. Y., & Teo, H. H. (2021) · Journal of Medical Internet Research · doi:10.2196/25759 · Cited by 419
Applications of deep learning in fundus images: A review
Li, T., Bo, W., Hu, C., Kang, H., Liu, H., Wang, K., & Fu, H. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101971 · Cited by 396
Chaki, J., Thillai Ganesh, S., Cidham, S. K., & Ananda Theertan, S. (2022) · Journal of King Saud University - Computer and Information Sciences · doi:10.1016/j.jksuci.2020.06.013 · Cited by 270
Predicting the risk of developing diabetic retinopathy using deep learning
Bora, A., Balasubramanian, S., Babenko, B., Virmani, S., Venugopalan, S., Mitani, A., de Oliveira Marinho, G., Cuadros, J., Ruamviboonsuk, P., Corrado, G. S., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30250-8 · Cited by 270
Metadata
- Authors
- Natarajan, S., Jain, A., Krishnan, R., Rogye, A., & Sivaprasad, S.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2019-10-01
- Volume
- 137
- Issue
- 10
- Pages
- 1182
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2968617104
- Cited by
- 228
- References
- 5
- FWCI
- 16.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Community-Based Diabetic Retinopathy Screening With an Offline Artificial Intelligence System on a Smartphone. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2019.2923
- The paper
- Natarajan, S., Jain, A., Krishnan, R., Rogye, A., & Sivaprasad, S. (2019). Diagnostic Accuracy of Community-Based Diabetic Retinopathy Screening With an Offline Artificial Intelligence System on a Smartphone. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2019.2923
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.