Abstract
Importance: Bedside monitor alarms alert nurses to life-threatening physiologic changes among patients, but the response times of nurses are slow. Objective: To identify factors associated with physiologic monitor alarm response time. Design, Setting, and Participants: This prospective cohort study used 551 hours of video-recorded care administered by 38 nurses to 100 children in a children's hospital medical unit between July 22, 2014, and November 11, 2015. Exposures: Patient, nurse, and alarm-level factors hypothesized to predict response time. Main Outcomes and Measures: We used multivariable accelerated failure-time models stratified by each nurse and adjusted for clustering within patients to evaluate associations between exposures and response time to alarms that occurred while the nurse was outside the room. Results: The study participants included 38 nurses, 100% (n = 38) of whom were white and 92% (n = 35) of whom were female, and 100 children, 51% (n = 51) of whom were male. The race/ethnicity of the child participants was 45% (n = 45) black or African American, 33% (n = 33) white, 4% (n = 4) Asian, and 18% (n = 18) other. Of 11 745 alarms among 100 children, 50 (0.5%) were actionable. The adjusted median response time among nurses was 10.4 minutes (95% CI, 5.0-15.8) and varied based on the following variables: if the patient was on complex care service (5.3 minutes [95% CI, 1.4-9.3] vs 11.1 minutes [95% CI, 5.6-16.6] among general pediatrics patients), whether family members were absent from the patient's bedside (6.3 minutes [95% CI, 2.2-10.4] vs 11.7 minutes [95% CI, 5.9-17.4] when family present), whether a nurse had less than 1 year of experience (4.4 minutes [95% CI, 3.4-5.5] vs 8.8 minutes [95% CI, 7.2-10.5] for nurses with 1 or more years of experience), if there was a 1 to 1 nursing assignment (3.5 minutes [95% CI, 1.3-5.7] vs 10.6 minutes [95% CI, 5.3-16.0] for nurses caring for 2 or more patients), if there were prior alarms requiring intervention (5.5 minutes [95% CI, 1.5-9.5] vs 10.7 minutes [5.2-16.2] for patients without intervention), and if there was a lethal arrhythmia alarm (1.2 minutes [95% CI, -0.6 to 2.9] vs 10.4 minutes [95% CI, 5.1-15.8] for alarms for other conditions). Each hour that elapsed during a nurse's shift was associated with a 15% longer response time (6.1 minutes [95% CI, 2.8-9.3] in hour 2 vs 14.1 minutes [95% CI, 6.4-21.7] in hour 8). The number of nonactionable alarms to which the nurse was exposed in the preceding 120 minutes was not associated with response time. Conclusions and Relevance: Response time was associated with factors that likely represent the heuristics nurses use to assess whether an alarm represents a life-threatening condition. The nurse to patient ratio and physical and mental fatigue (measured by the number of hours into a shift) represent modifiable factors associated with response time. Chronic alarm fatigue resulting from long-term exposure to nonactionable alarms may be a more important determinant of response time than short-term exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183 · cited 5×
“Actionable alarm: A valid clinical alarm that either (1) leads to an observed clinical intervention (such as initiating supplemental oxygen) or (2) leads to an observed consultation with another clinician (such as discussing the patient’s tachycardia with a resident) at the bedside or (3) warrants intervention or cons…”
BackgroundMethodResultInfluentialSelf-citationEffect of dedicated monitor watchers on patients' outcomes
Funk, M., Parkosewich, J., Johnson, C., & Stukshis, I. (1997) · American Journal of Critical Care · doi:10.4037/ajcc1997.6.4.318 · Cited by 34
Cited by
Role of artificial intelligence in patient safety outcomes: systematic literature review
Choudhury, A., & Asan, O. (2020) · JMIR Medical Informatics · doi:10.2196/18599 · Cited by 440
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Downing, N. L., Rolnick, J., Poole, S. F., Hall, E., Wessels, A. J., Heidenreich, P., & Shieh, L. (2019) · BMJ Quality & Safety · doi:10.1136/bmjqs-2018-008765 · Cited by 112
Chaparro, J. D., Beus, J. M., Dziorny, A. C., Hagedorn, P. A., Hernandez, S., Kandaswamy, S., Kirkendall, E. S., McCoy, A. B., Muthu, N., & Orenstein, E. W. (2022) · Applied Clinical Informatics · doi:10.1055/s-0042-1748856 · Cited by 76
Psihogios, A. M., Li, Y., Butler, E., Hamilton, J., Daniel, L. C., Barakat, L. P., Bonafide, C. P., & Schwartz, L. A. (2019) · JMIR mhealth and uhealth · doi:10.2196/12547 · Cited by 24
“Future research should also evaluate the latency of responsivity, such as the elapsed time to respond to text messages, as studying response times has yielded valuable information in other health areas (eg, factors that influence health providers’ response times to patient physiological monitors) [53].”
Self-citation
Metadata
- Authors
- Bonafide, C. P., Localio, A. R., Holmes, J. H., Nadkarni, V. M., Stemler, S., MacMurchy, M., Zander, M., Roberts, K. E., Lin, R., & Keren, R.
- Venue
- JAMA Pediatrics
- Publisher
- American Medical Association (AMA)
- Published
- 2017-06-01
- Volume
- 171
- Issue
- 6
- Pages
- 524
- ISSN
- 1072-4710 (ISSN-L)
- 2168-6203
- OpenAlex
- W2606051733
- Cited by
- 86
- References
- 3
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video Analysis of Factors Associated With Response Time to Physiologic Monitor Alarms in a Children’s Hospital. https://app.cochat.ai/papers/10.1001/jamapediatrics.2016.5123
- The paper
- Bonafide, C. P., Localio, A. R., Holmes, J. H., Nadkarni, V. M., Stemler, S., MacMurchy, M., Zander, M., Roberts, K. E., Lin, R., & Keren, R. (2017). Video Analysis of Factors Associated With Response Time to Physiologic Monitor Alarms in a Children’s Hospital. JAMA Pediatrics. https://doi.org/10.1001/jamapediatrics.2016.5123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.