Biologic vs Synthetic Mesh for Single-stage Repair of Contaminated Ventral Hernias: A Randomized Clinical Trial
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Biologic mesh is widely used for reinforcing contaminated ventral hernia repairs; however, it is expensive and has been associated with high rates of long-term hernia recurrence. Synthetic mesh is a lower-cost alternative but its efficacy has not been rigorously studied in individuals with contaminated hernias. OBJECTIVE: To determine whether synthetic mesh results in superior reduction in risk of hernia recurrence compared with biologic mesh during the single-stage repair of clean-contaminated and contaminated ventral hernias. DESIGN, SETTING, AND PARTICIPANTS: This multicenter, single-blinded randomized clinical trial was conducted from December 2012 to April 2019 with a follow-up duration of 2 years. The trial was completed at 5 academic medical centers in the US with specialized units for abdominal wall reconstruction. A total of 253 adult patients with clean-contaminated or contaminated ventral hernias were enrolled in this trial. Follow-up was completed in April 2021. INTERVENTIONS: Retromuscular synthetic or biologic mesh at the time of fascial closure. MAIN OUTCOMES AND MEASURES: The primary outcome was the superiority of synthetic mesh vs biologic mesh at reducing risk of hernia recurrence at 2 years based on intent-to-treat analysis. Secondary outcomes included mesh safety, defined as the rate of surgical site occurrence requiring a procedural intervention, and 30-day hospital direct costs and prosthetic costs. RESULTS: A total of 253 patients (median [IQR] age, 64 [55-70] years; 117 [46%] male) were randomized (126 to synthetic mesh and 127 to biologic mesh) and the follow-up rate was 92% at 2 years. Compared with biologic mesh, synthetic mesh significantly reduced the risk of hernia recurrence (hazard ratio, 0.31; 95% CI, 0.23-0.42; P < .001). The overall intent-to-treat hernia recurrence risk at 2 years was 13% (33 of 253 patients). Recurrence risk with biologic mesh was 20.5% (26 of 127 patients) and with synthetic mesh was 5.6% (7 of 126 patients), with an absolute risk reduction of 14.9% with the use of synthetic mesh (95% CI, -23.8% to -6.1%; P = .001). There was no significant difference in overall 2-year risk of surgical site occurrence requiring a procedural intervention between the groups (odds ratio, 1.22; 95% CI, 0.60-2.44; P = .58). Median (IQR) 30-day hospital direct costs were significantly greater in the biologic group vs the synthetic group ($44 936 [$35 877-$52 656] vs $17 289 [$14 643-$22 901], respectively; P < .001). There was also a significant difference in the price of the prosthetic device between the 2 groups (median [IQR] cost biologic, $21 539 [$20 285-$23 332] vs synthetic, $105 [$105-$118]; P < .001). CONCLUSIONS AND RELEVANCE: Synthetic mesh demonstrated superior 2-year hernia recurrence risk compared with biologic mesh in patients undergoing single-stage repair of contaminated ventral hernias, and both meshes demonstrated similar safety profiles. The price of biologic mesh was over 200 times that of synthetic mesh for these outcomes. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02451176.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials
Schulz, K. F., Altman, D. G., Moher, D., & for the CONSORT Group* (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-11-201006010-00232 · Cited by 3,824
The Argument for Lightweight Polypropylene Mesh in Hernia Repair
Cobb, W. S., Kercher, K. W., & Heniford, B. T. (2005) · Surgical Innovation · doi:10.1177/155335060501200109 · Cited by 364
Huerta, S., Varshney, A., Patel, P. M., Mayo, H. G., & Livingston, E. H. (2016) · JAMA Surgery · doi:10.1001/jamasurg.2015.5234 · Cited by 71
Cited by
Capella-Monsonís, H., Crum, R. J., Hussey, G. S., & Badylak, S. F. (2024) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2024.115347 · Cited by 84
Metadata
- Authors
- Rosen, M. J., Krpata, D. M., Petro, C. C., Carbonell, A., Warren, J., Poulose, B. K., Costanzo, A., Tu, C., Blatnik, J., & Prabhu, A. S.
- Venue
- JAMA Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 2022-04-01
- Volume
- 157
- Issue
- 4
- Pages
- 293
- ISSN
- 2168-6254 (ISSN-L)
- OpenAlex
- W4205883258
- Cited by
- 198
- References
- 4
- FWCI
- 33.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biologic vs Synthetic Mesh for Single-stage Repair of Contaminated Ventral Hernias: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jamasurg.2021.6902
- The paper
- Rosen, M. J., Krpata, D. M., Petro, C. C., Carbonell, A., Warren, J., Poulose, B. K., Costanzo, A., Tu, C., Blatnik, J., & Prabhu, A. S. (2022). Biologic vs Synthetic Mesh for Single-stage Repair of Contaminated Ventral Hernias: A Randomized Clinical Trial. JAMA Surgery. https://doi.org/10.1001/jamasurg.2021.6902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.