Native Mass Spectrometry as a Tool in Structural Biology
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Native mass spectrometry (native MS) gives information about the composition, topological arrangements, dynamics, and structural properties of protein complexes. The mass range is principally unlimited and highly dynamic, allowing the detection of small subunits and large complexes within the same measurement. The amount of protein needed for an analysis is, compared to most other structural biology methods, very low. This unit provides an introduction to native MS. It starts with an explanation of the basic method and details on how to measure intact proteins and protein complexes, and continues with the study of dynamics and complex stability in the gas phase. The final section discusses the most recent extension to the native MS field, ion mobility, which allows the direct assessment of the structural properties of the complexes of interest. Curr. Protoc. Protein Sci. 62:17.12.1‐17.12.17. © 2010 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766 · cited 1×
“This was first shown by Hernandez et al. (2006) and Synowsky et al. (2006) and has since then become a generic approach (Fig.”
BackgroundA Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511 · cited 1×
“Experiments with imidazole as a charge-reducing agent have shown that lowering the charge state has the effect of inducing more compact, i.e., native-like, protein structures (Sun et al., 2007; Bagal et al., 2009; van Duijn et al., 2009).”
BackgroundTime-of-flight mass spectrometry (concepts, achievements, and prospects)
Mamyrin, B. A. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00392-4 · Cited by 251 · cited 1×
“The cause for this is insufficient evaporation of the buffer substances (McKay et al., 2006).”
Background
Cited by
Cross-Linking Mass Spectrometry: An Emerging Technology for Interactomics and Structural Biology
Yu, C., & Huang, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04431 · Cited by 353
Native vs Denatured: An in Depth Investigation of Charge State and Isotope Distributions
Kafader, J. O., Melani, R. D., Schachner, L. F., Ives, A. N., Patrie, S. M., Kelleher, N. L., & Compton, P. D. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00040 · Cited by 51
Gavriilidou, A. F. M., Gülbakan, B., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02478 · Cited by 53
Crittenden, C. M., Novelli, E. T., Mehaffey, M. R., Xu, G. N., Giles, D. H., Fies, W. A., Dalby, K. N., Webb, L. J., & Brodbelt, J. S. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00066 · Cited by 24
Metadata
- Authors
- Lorenzen, K., & Duijn, E. V.
- Venue
- Current Protocols in Protein Science
- Publisher
- Wiley
- Published
- 2010-11
- Volume
- 62
- Issue
- 1
- Pages
- Unit17.12-Unit17.12
- ISSN
- 1934-3655 (ISSN-L)
- 1934-3663
- OpenAlex
- W1571818877
- Cited by
- 55
- References
- 3
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.