A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies

Sobott, Frank, Hernández, Helena, McCammon, Margaret G., Tito, Mark A., Robinson, Carol V.·2002·Analytical Chemistry

Abstract

We report the design and first applications of a tandem mass spectrometer (a quadrupole time-of-flight mass spectrometer) optimized for the transmission and analysis of large macromolecular assemblies. Careful control of the pressure gradient in the different pumping stages of the instrument has been found to be essential for the detection of macromolecular particles. Such assemblies are, however, difficult to analyze by tandem-MS approaches, because they give rise to signals above m/z 3,000-4,000, the limit for commercial quadrupoles. By reducing the frequency of the quadrupole to 300 kHz and using it as a narrow-band mass filter, we show that it is possible to isolate ions from a single peak at m/z 22,000 in a window as narrow as 22 m/z units. Using cesium iodide cluster signals, we show that the mass range in the time-of-flight (TOF) analyzer extends beyond m/z 90,000, in theory to more than m/z 150,000. We also demonstrate that the resolution of the instrument is greater than 3,000 at m/z 44,500. Tandem-MS capabilities are illustrated by separating components from heterooligomeric assemblies formed between tetrameric transthyretin, thyroxine, retinol-binding protein, and retinol. Isolation of a single charge state at m/z 5,340 in the quadrupole and subsequent collision-induced dissociation (CID) in the gas-filled collision cell leads to the formation of ions from individual subunits and subcomplexes, identified by their mass and charge in the TOF analyzer.

Integrity signals

Registry

Crossref · 10.1021/ac0110552

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V.
Affiliations
University of Cambridge (GB)
Venue
Analytical Chemistry
Published
2002-02-16
Volume
74
Issue
6
Pages
1402-1407
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2066011752
Cited by
511
References
19
Citations by year
2026: 4 · 2025: 11 · 2024: 11 · 2023: 18 · 2022: 11 · 2021: 26 · 2020: 21 · 2019: 20 · 2018: 18 · 2017: 27 · 2016: 25 · 2015: 29 · 2014: 34 · 2013: 26 · 2012: 24
FWCI
8.67
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Royal Society
  • Medical Research Council
  • Engineering and Physical Sciences Research Council
  • Biotechnology and Biological Sciences Research Council
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
tandem mass spectrometry, ion transmission, quadrupole frequency, prealbumin, thyroxine, retinol-binding protein, retinol, collision-induced dissociation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review