The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Open accessAbstract
BACKGROUND: In acute asthma inhaled beta(2)-agonists are often administered by nebuliser to relieve bronchospasm, but some have argued that metered-dose inhalers with a holding chamber (spacer) can be equally effective. Nebulisers require a power source and need regular maintenance, and are more expensive in the community setting. OBJECTIVES: To assess the effects of holding chambers (spacers) compared to nebulisers for the delivery of beta(2)-agonists for acute asthma. SEARCH METHODS: We searched the Cochrane Airways Group Trial Register and reference lists of articles. We contacted the authors of studies to identify additional trials. Date of last search: February 2013. SELECTION CRITERIA: Randomised trials in adults and children (from two years of age) with asthma, where spacer beta(2)-agonist delivery was compared with wet nebulisation. DATA COLLECTION AND ANALYSIS: Two review authors independently applied study inclusion criteria (one review author for the first version of the review), extracted the data and assessed risks of bias. Missing data were obtained from the authors or estimated. Results are reported with 95% confidence intervals (CIs). MAIN RESULTS: This review includes a total of 1897 children and 729 adults in 39 trials. Thirty-three trials were conducted in the emergency room and equivalent community settings, and six trials were on inpatients with acute asthma (207 children and 28 adults). The method of delivery of beta(2)-agonist did not show a significant difference in hospital admission rates. In adults, the risk ratio (RR) of admission for spacer versus nebuliser was 0.94 (95% CI 0.61 to 1.43). The risk ratio for children was 0.71 (95% CI 0.47 to 1.08, moderate quality evidence). In children, length of stay in the emergency department was significantly shorter when the spacer was used. The mean duration in the emergency department for children given nebulised treatment was 103 minutes, and for children given treatment via spacers 33 minutes less (95% CI -43 to -24 minutes, moderate quality evidence). Length of stay in the emergency department for adults was similar for the two delivery methods. Peak flow and forced expiratory volume were also similar for the two delivery methods. Pulse rate was lower for spacer in children, mean difference -5% baseline (95% CI -8% to -2%, moderate quality evidence), as was the risk of developing tremor (RR 0.64; 95% CI 0.44 to 0.95, moderate quality evidence). AUTHORS' CONCLUSIONS: Nebuliser delivery produced outcomes that were not significantly better than metered-dose inhalers delivered by spacer in adults or children, in trials where treatments were repeated and titrated to the response of the participant. Spacers may have some advantages compared to nebulisers for children with acute asthma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582
GLOBAL STRATEGY FOR ASTHMA MANAGEMENT AND PREVENTION
PAUWELS, R. A. (1996) · Arerugī/Arerugi · doi:10.15036/arerugi.45.792 · Cited by 9,994
British Guideline on the Management of Asthma
British Thoracic Society Scottish Intercollegiate Guidelines Network (2008) · Thorax · doi:10.1136/thx.2008.097741 · Cited by 2,021
Corticosteroids for preventing relapse following acute exacerbations of asthma
Rowe, B. H., Spooner, C., Ducharme, F., Bretzlaff, J., & Bota, G. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000195.pub2 · Cited by 344
Self-citationImprovement of pressurised aerosol deposition with Nebuhaler spacer device.
Newman, S. P., Millar, A. B., Lennard-Jones, T. R., Moren, F., & Clarke, S. W. (1984) · Thorax · doi:10.1136/thx.39.12.935 · Cited by 257
Bronchodilator Delivery in Acute Airflow Obstruction: A Meta-analysis
TURNER, M. O., Patel, A., Ginsburg, S., & FitzGerald, J. M. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440360162018 · Cited by 201
Wildhaber, J. H., Dore, N. D., Wilson, J. M., Devadason, S. G., & LeSouëf, P. N. (1999) · The Journal of Pediatrics · doi:10.1016/s0022-3476(99)70323-9 · Cited by 192
Bronchodilator delivery in acute airflow obstruction. A meta-analysis
Turner, M. O. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.157.15.1736 · Cited by 179
Holding chambers versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Bara, A., Crilly, J. A., & Rowe, B. (2003) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052 · Cited by 147
Self-citationHolding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Crilly, J. A., & Rowe, B. H. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052.pub2 · Cited by 138
Self-citation
Cited by
Vanden Hoek, T. L., Morrison, L. J., Shuster, M., Donnino, M., Sinz, E., Lavonas, E. J., Jeejeebhoy, F. M., & Gabrielli, A. (2010) · Circulation · doi:10.1161/circulationaha.110.971069 · Cited by 720
Asthma Exacerbations: Pathogenesis, Prevention, and Treatment
Castillo, J. R., Peters, S. P., & Busse, W. W. (2017) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2017.05.001 · Cited by 544
International consensus on (ICON) pediatric asthma
Papadopoulos, N. G., Arakawa, H., Carlsen, K. ‐., Custovic, A., Gern, J., Lemanske, R., Le Souef, P., Mäkelä, M., Roberts, G., Wong, G., et al. (2012) · Allergy · doi:10.1111/j.1398-9995.2012.02865.x · Cited by 455
European Resuscitation Council Guidelines 2021: Paediatric Life Support
Van de Voorde, P., Turner, N. M., Djakow, J., de Lucas, N., Martinez-Mejias, A., Biarent, D., Bingham, R., Brissaud, O., Hoffmann, F., Johannesdottir, G. B., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.015 · Cited by 448
Metadata
- Authors
- Cates, C. J., Welsh, E. J., & Rowe, B. H.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2013-09-13
- Volume
- 2014
- Issue
- 6
- Pages
- CD000052-CD000052
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2168363802
- Cited by
- 359
- References
- 15
- FWCI
- 15.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma. https://app.cochat.ai/papers/10.1002/14651858.cd000052.pub3
- The paper
- Cates, C. J., Welsh, E. J., & Rowe, B. H. (2013). Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd000052.pub3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.