Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Improvement of pressurised aerosol deposition with Nebuhaler spacer device.

Open access
Newman, S P, Millar, A B, Lennard-Jones, T R, Moren, F, Clarke, S W·1984·Thorax

Abstract

The effect on aerosol deposition from a pressurised metered dose inhaler of a 750 cm3 spacer device with a one way inhalation valve (Nebuhaler, Astra Pharmaceuticals) was assessed by means of an in vivo radiotracer technique. Nine patients with obstructive lung disease took part in the study. The pattern of deposition associated with use of a metered dose inhaler alone was compared with that achieved with the spacer used both for inhalation of single puffs of aerosol and for inhalation of four puffs actuated in rapid succession and then inhaled simultaneously. On each occasion there was a delay of 1 s between aerosol release and inhalation, simulating poor inhaler technique. With the metered dose inhaler alone, a mean (SEM) 8.7 (1.8)% of the dose reached the lungs and 80.9 (1.9)% was deposited in the oropharynx. With single puffs from the spacer 20.9 (1.6)% of the dose (p less than 0.01) reached the lungs, only 16.5 (2.3)% (p less than 0.01) was deposited in the oropharynx, and 55.8 (3.1)% was retained within the spacer itself. With four puffs from the spacer 15.2 (1.5)% reached the lungs (p = 0.02 compared with the metered dose inhaler alone, p less than 0.01 compared with single puffs from the spacer), 11.4 (1.2)% was deposited in the oropharynx, and 67.5 (1.8)% in the device itself. It is concluded that the spacer device gives lung deposition of metered dose aerosols comparable to or greater than a correctly used inhaler and oropharyngeal deposition is greatly reduced. The spacer should be used preferably for the inhalation of single puffs of aerosol but may also be used for the inhalation of up to four puffs actuated in rapid succession and then inhaled simultaneously.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.39.12.935

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 257

Metadata

Authors
Newman, S. P., Millar, A. B., Lennard-Jones, T. R., Moren, F., & Clarke, S. W.
Venue
Thorax
Publisher
BMJ
Published
1984-12-01
Volume
39
Issue
12
Pages
935-941
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2134494103
Cited by
257
References
6
FWCI
6.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement of pressurised aerosol deposition with Nebuhaler spacer device. https://app.cochat.ai/papers/10.1136/thx.39.12.935
The paper
Newman, S. P., Millar, A. B., Lennard-Jones, T. R., Moren, F., & Clarke, S. W. (1984). Improvement of pressurised aerosol deposition with Nebuhaler spacer device. Thorax. https://doi.org/10.1136/thx.39.12.935

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.