The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Fetal electrocardiogram (ECG) for fetal monitoring during labour
Open accessAbstract
BACKGROUND: Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. OBJECTIVES: To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. SEARCH METHODS: The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. DATA COLLECTION AND ANALYSIS: One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. MAIN RESULTS: Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average fewer fetal scalp samples taken during labour (average RR 0.61, 95% CI 0.41 to 0.91; four trials, 9671 babies; high quality evidence) although the findings were heterogeneous and there were no data from the largest trial (from the USA). There were marginally fewer operative vaginal births (RR 0.92, 95% CI 0.86 to 0.99; six trials, 26,446 women); but no obvious difference in the number of babies with low Apgar scores at five minutes or babies requiring neonatal intubation, or babies requiring admission to the special care unit (RR 0.96, 95% CI 0.89 to 1.04, six trials, 26,410 babies; high quality evidence). There was little evidence that monitoring by PR interval analysis conveyed any benefit of any sort. AUTHORS' CONCLUSIONS: The modest benefits of fewer fetal scalp samplings during labour (in settings in which this procedure is performed) and fewer instrumental vaginal births have to be considered against the disadvantages of needing to use an internal scalp electrode, after membrane rupture, for ECG waveform recordings. We found little strong evidence that ST waveform analysis had an effect on the primary outcome measures in this systematic review.There was a lack of evidence showing that PR interval analysis improved any outcomes; and a larger future trial may possibly demonstrate beneficial effects.There is little information about the value of fetal ECG waveform monitoring in preterm fetuses in labour. Information about long-term development of the babies included in the trials would be valuable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Cochrane Handbook for Systematic Reviews of Interventions Version 5.0.1. The Cochrane Collaboration
Higgins, J., Green, S. R., & Higgins, J. (2008) · Cited by 5,544
Meta-analyses involving cross-over trials: methodological issues
Elbourne, D. R., Altman, D. G., Higgins, J. P., Curtin, F., Worthington, H. V., & Vail, A. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.140 · Cited by 2,305
A modified test for small‐study effects in meta‐analyses of controlled trials with binary endpoints
Harbord, R. M., Egger, M., & Sterne, J. A. C. (2006) · Statistics in Medicine · doi:10.1002/sim.2380 · Cited by 2,267
Published by John Wiley & Sons Ltd
Modarresi, O. A. F., & Shakibaie, M. M. M. R. (2015) · Cited by 1,111
Alfirevic, Z., Devane, D., & Gyte, G. M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066 · Cited by 1,035
Amer-Wåhlin, I., Hellsten, C., Norén, H., Hagberg, H., Herbst, A., Kjellmer, I., Lilja, H., Lindoff, C., Månsson, M., Mårtensson, L., et al. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05703-8 · Cited by 402
Westgate, J., Harris, M., Curnow, J. S. H., & Greene, K. R. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(93)90273-l · Cited by 238
Baillière's clinical obstetrics and gynaecology
Hancock, K. W. (1991) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(91)90112-x · Cited by 173
Cited by
Alfirevic, Z., Devane, D., & Gyte, G. M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066 · Cited by 1,035
Fetal movement counting for assessment of fetal wellbeing
Mangesi, L., Hofmeyr, G. J., Smith, V., & Smyth, R. M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004909.pub3 · Cited by 255
Obstetric care in low-resource settings: what, who, and how to overcome challenges to scale up?
Hofmeyr, G. J., Haws, R. A., Bergström, S., Lee, A. C., Okong, P., Darmstadt, G. L., Mullany, L. C., Oo, E. K. S., & Lawn, J. E. (2009) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2009.07.017 · Cited by 224
The future of electronic fetal monitoring
Knupp, R. J., Andrews, W. W., & Tita, A. T. N. (2020) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2020.02.004 · Cited by 29
Metadata
- Authors
- Neilson, J. P.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2015-12-21
- Volume
- 2015
- Issue
- 12
- Pages
- CD000116-CD000116
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1944618541
- Cited by
- 279
- References
- 38
- FWCI
- 23.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fetal electrocardiogram (ECG) for fetal monitoring during labour. https://app.cochat.ai/papers/10.1002/14651858.cd000116.pub5
- The paper
- Neilson, J. P. (2015). Fetal electrocardiogram (ECG) for fetal monitoring during labour. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd000116.pub5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.