Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Fetal movement counting for assessment of fetal wellbeing

Open access
Mangesi, Lindeka, Hofmeyr, G Justus, Smith, Valerie, Smyth, Rebecca MD·2015·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Fetal movement counting is a method by which a woman quantifies the movements she feels to assess the condition of her baby. The purpose is to try to reduce perinatal mortality by alerting caregivers when the baby might be compromised. This method may be used routinely, or only in women who are considered at increased risk of complications affecting the baby. Fetal movement counting may allow the clinician to make appropriate interventions in good time to improve outcomes. On the other hand, fetal movement counting may cause unnecessary anxiety to pregnant women, or elicit unnecessary interventions. OBJECTIVES: To assess outcomes of pregnancy where fetal movement counting was done routinely, selectively or was not done at all; and to compare different methods of fetal movement counting. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 May 2015) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised controlled trials (RCTs) and cluster-RCTs where fetal movement counting was assessed as a method of monitoring fetal wellbeing. DATA COLLECTION AND ANALYSIS: Two review authors assessed studies for eligibility, assessed the methodological quality of included studies and independently extracted data from studies. Where possible the effects of interventions were compared using risk ratios (RR), and presented with 95% confidence intervals (CI). For some outcomes, the quality of the evidence was assessed using the GRADE approach. MAIN RESULTS: Five studies (71,458 women) were included in this review; 68,654 in one cluster-RCT. None of these five trials were assessed as having low risk of bias on all seven risk of bias criteria. All included studies except for one (which included high-risk women as participants) included women with uncomplicated pregnancies.Two studies compared fetal movement counting with standard care, as defined by trial authors. Two included studies compared two types of fetal movement counting; once a day fetal movement counting (Cardiff count-to-10) with more than once a day fetal movement counting methods. One study compared fetal movement counting with hormone assessment.(1) Routine fetal movement counting versus mixed or undefined fetal movement countingNo study reported on the primary outcome 'perinatal death or severe morbidity'. In one large cluster-RCT, there was no difference in mean stillbirth rates per cluster (standard mean difference (SMD) 0.23, 95% CI -0.61 to 1.07; participants = 52 clusters; studies = one, low quality evidence). The other study reported no fetal deaths. There was no difference in caesarean section rate between groups (RR 0.93, 95% CI 0.60 to 1.44; participants = 1076; studies = one,low quality evidence). Maternal anxiety was significantly reduced with routine fetal movement counting (SMD -0.22, 95% CI -0.35 to -0.10; participants = 1013; studies = one, moderate quality evidence). Maternal-fetal attachment was not significantly different (SMD -0.02, 95% CI -0.15 to 0.11; participants = 951; studies = one, low quality evidence). In one study antenatal admission after reporting of decreased fetal movements was increased (RR 2.72, 95% CI 1.34 to 5.52; participants = 123; studies = one). In another there was a trend to more antenatal admissions per cluster in the counting group than in the control group (SMD 0.38, 95% CI -0.17 to 0.93; participants = 52 clusters; studies = one, low quality evidence). Birthweight less than 10th centile was not significantly different between groups (RR 0.98, 95% CI 0.66 to 1.44; participants = 1073; studies = one, low quality evidence). The evidence was of low quality due to imprecise results and because of concerns regarding unclear risk of bias. (2) Formal fetal movement counting (Modified Cardiff method) versus hormone analysisThere was no difference between the groups in the incidence of caesarean section (RR 1.18, 95% CI 0.83 to 1.69; participants = 1191; studies = one). Women in the formal fetal movement counting group had significantly fewer hospital visits than those randomised to hormone analysis (RR 0.26, 95% CI 0.20 to 0.35), whereas there were fewer Apgar scores less than seven at five minutes for women randomised to hormone analysis (RR 1.72, 95% CI 1.01 to 2.93). No other outcomes reported showed statistically significant differences. 'Perinatal death or severe morbidity' was not reported. (3) Formal fetal movement counting once a day (count-to-10) versus formal fetal movement counting method where counting was done more than once a day (after meals)The incidence of caesarean section did not differ between the groups under this comparison (RR 2.33, 95% CI 0.61 to 8.99; participants = 1400; studies = one). Perinatal death or severe morbidity was not reported. Women were more compliant in using the count-to-10 method than they were with other fetal movement counting methods, citing less interruption with daily activities as one of the reasons (non-com

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd004909.pub3

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 36 references

Cited by

See all 255

Metadata

Authors
Mangesi, L., Hofmeyr, G. J., Smith, V., & Smyth, R. M.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2015-10-15
Volume
2015
Issue
10
Pages
CD004909-CD004909
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2058546152
Cited by
255
References
36
FWCI
15.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fetal movement counting for assessment of fetal wellbeing. https://app.cochat.ai/papers/10.1002/14651858.cd004909.pub3
The paper
Mangesi, L., Hofmeyr, G. J., Smith, V., & Smyth, R. M. (2015). Fetal movement counting for assessment of fetal wellbeing. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd004909.pub3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.