Cited by 198Pregnancy and preeclampsia studiesMaternal and Perinatal Health InterventionsPrenatal Screening and Diagnostics

The DOI matches its Crossref record; 65 of the 67 references it cites were found in a registry or an index.

Fetal and umbilical Doppler ultrasound in normal pregnancy

Open access
Alfirevic, Zarko, Stampalija, Tamara, Medley, Nancy·2015·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: One of the main aims of routine antenatal care is to identify the 'at risk' fetus in order to apply clinical interventions which could result in reduced perinatal morbidity and mortality. Doppler ultrasound study of umbilical artery waveforms helps to identify the compromised fetus in 'high-risk' pregnancies and, therefore, deserves assessment as a screening test in 'low-risk' pregnancies. OBJECTIVES: To assess the effects on obstetric practice and pregnancy outcome of routine fetal and umbilical Doppler ultrasound in unselected and low-risk pregnancies. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group Trials Register (28 February 2015) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in unselected pregnancies compared with no Doppler ultrasound. Studies where uterine vessels have been assessed together with fetal and umbilical vessels have been included. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. In addition to standard meta-analysis, the two primary outcomes and five of the secondary outcomes were assessed using GRADE software and methodology. MAIN RESULTS: We included five trials that recruited 14,624 women, with data analysed for 14,185 women. All trials had adequate allocation concealment, but none had adequate blinding of participants, staff or outcome assessors. Overall and apart from lack of blinding, the risk of bias for the included trials was considered to be low.Overall, routine fetal and umbilical Doppler ultrasound examination in low-risk or unselected populations did not result in increased antenatal, obstetric and neonatal interventions. There were no group differences noted for the review's primary outcomes of perinatal death and neonatal morbidity. Results for perinatal death were as follows: (average risk ratio (RR) 0.80, 95% confidence interval (CI) 0.35 to 1.83; four studies, 11,183 participants). Only one included trial assessed serious neonatal morbidity and found no evidence of group differences (RR 0.99, 95% CI 0.06 to 15.75; one study, 2016 participants).For the comparison of a single Doppler assessment versus no Doppler, evidence for group differences in perinatal death was detected (RR 0.36, 95% CI 0.13 to 0.99; one study, 3891 participants). However, these results are based on a single trial, and we would recommend caution when interpreting this finding.There was no evidence of group differences for the outcomes of caesarean section, neonatal intensive care admissions or preterm birth less than 37 weeks.When the quality of the evidence for the main comparison of 'All Doppler versus no Doppler' was assessed with GRADE software, the outcomes of perinatal death and serious neonatal morbidity data were graded as of low quality. Evidence for the outcome of stillbirth was graded according to regimen subgroups - with a moderate quality rating for stillbirth (fetal/umbilical vessels only) and a low quality rating for stillbirth (fetal/umbilical vessels + uterine artery vessels). Evidence for admission to neonatal intensive care unit was assessed as of moderate quality, and evidence for the outcomes of caesarean section and preterm birth less than 37 weeks was graded as of high quality.There is no available evidence to assess the effect on substantive long-term outcomes such as childhood neurodevelopment and no data to assess maternal outcomes, particularly maternal satisfaction. AUTHORS' CONCLUSIONS: Existing evidence does not provide conclusive evidence that the use of routine umbilical artery Doppler ultrasound, or combination of umbilical and uterine artery Doppler ultrasound in low-risk or unselected populations benefits either mother or baby. Future studies should be designed to address small changes in perinatal outcome, and should focus on potentially preventable deaths.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd001450.pub4

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

2 retracted

Show all 67 references

Research works printed but not linked: 16

  1. Davies J Spencer J Gallivan S Randomised trial of Doppler screening in a general obstetric population Proceedings of the 26th British Congress of Obstetrics and Gynaecology; 1992 July 7-10; Manchester, UK 1992 316
  2. Spencer, 1992, Randomised trial of routine Doppler screening during pregnancy, Journal of Maternal Fetal Investigation, 1, 126
  3. Newnham J MacDonald W Gurrin L Evans S Landau L Stanley F The effect of frequent prenatal ultrasound on birthweight: follow up at one year of age Proceedings of the 14th Australian Perinatal Society in conjunction with the New Zealand Perinatal Society; 1996 March 24-27; Adelaide, Australia 1996 A26
  4. Schneider, 1992, Doppler flow measurements as a screening method during pregnancy: Is it worth the effort?, Journal of Maternal Fetal Investigation, 1, 125
  5. Subtil, 2000, Value of systematic doppler +/- low dose aspirin to prevent vascular complications in primigravidae, Hypertension in Pregnancy, 19, 9
  6. Chalmers, 1989, Evaluating the effects of care during pregnancy and childbirth, 1, 3
  7. Fisk, 2001, Fetal growth restriction; small for gestational age, 197
  8. Forward, 2014, Multiple prenatal ultrasound scans and ocular development: 20-year follow-up of a randomised, controlled trial, Ultrasound in Obstetrics & Gynecology, 44, 166, 10.1002/uog.13399 · DOI
  9. Newnham J MacDonald W Gurrin L Evans S Landau L Stanley F The effect of frequent prenatal ultrasound on birthweight: follow-up at one year of age Proceedings of the 14th Annual Congress of the Australian Perinatal Society in conjunction with the New Zealand Perinatal Society; 1996 March 24-27; Adelaide, Australia 1996 A26
  10. National Institute for Health and Clinical Excellence, 2008, Antenatal Care: Routine Care for the Healthy Pregnant Women. NICE Clinical Guideline 62 (March 2008)
  11. Owen, 2001, Fetal assessment in the third trimester: fetal growth and biophysical methods
  12. Royal College of Obstetricians and Gynaecologists, 1997, Ultrasound Screening for Fetal Abnormalities: Report of the RCOG Working Party
  13. RevMan Review Manager (RevMan) Version 5.0 for Windows 2008
  14. The Nordic Cochrane Centre, The Cochrane Collaboration Review Manager (RevMan) 2014
  15. Schunemann, 2009, GRADE: from grading the evidence to developing recommendations. A description of the system and a proposal regarding the transferability of the results of clinical research to clinical practice, Zeitschrift fur Evidenz, Fortbildung und Qualitat im Gesundheitswesen, 103, 391
  16. Stoch, 2012, Are prenatal ultrasound scans associated with the autism phenotype? Follow-up of a randomised controlled trial, Journal of Autism & Developmental Disorders, 42, 2693, 10.1007/s10803-012-1526-8 · DOI

Cited by

Sorted by citations

Metadata

Authors
Alfirevic, Z., Stampalija, T., & Medley, N.
Affiliations
  • The University of Liverpool; Department of Women's and Children's Health; First Floor, Liverpool Women's NHS Foundation Trust Crown Street Liverpool UK L8 7SS
  • IRCCS Materno Infantile Burlo Garofolo (IT)
  • University of Liverpool (GB)
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2015-04-15
Volume
2015
Issue
6
Pages
CD001450-CD001450
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W1550707014
Cited by
198
References
67
Citations by year
2026: 6 · 2025: 11 · 2024: 11 · 2023: 18 · 2022: 12 · 2021: 22 · 2020: 15 · 2019: 14 · 2018: 21 · 2017: 18 · 2016: 15 · 2015: 10
FWCI
3.13
Type
journal article
Language
en
Open access
Locations
  • Cochrane Database of Systematic Reviews (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • World Health Organization
  • UNICEF
  • McMaster University
  • National Institute for Health and Care Research
  • Evidence Synthesis Programme
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
Keywords
fetal Doppler, umbilical artery Doppler, low-risk pregnancy, prenatal screening, perinatal death, neonatal morbidity, obstetric surgery, fetal growth restriction, fetal heart rate monitoring, fetal biometry, uterine artery Doppler, fetal monitoring
MeSH terms
Female, Humans, Infant, Newborn, Pregnancy, Pregnancy Outcome, Umbilical Arteries, Randomized Controlled Trials as Topic, Ultrasonography, Prenatal, Ultrasonography, Doppler, Perinatal Mortality, Uterine Artery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review