Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record.

Surgical sealant for preventing air leaks after pulmonary resections in patients with lung cancer

Open access
Belda-Sanchís, José, Serra-Mitjans, Mireia, Iglesias Sentis, Manuela, Rami, Ramon · 2010 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Postoperative air leak is a frequent complication after pulmonary resection for lung cancer. It may cause serious complications, such as empyema, or prolong the need for chest tube and hospitalization. Different types of surgical sealants have been developed to prevent or to reduce postoperative air leaks. A systematic review was therefore undertaken to evaluate the evidence on their effectiveness. OBJECTIVES: To evaluate the effectiveness of surgical sealants in preventing or reducing postoperative air leaks after pulmonary resection for lung cancer. SEARCH STRATEGY: We searched the electronic databases MEDLINE (1966 to September 2008), EMBASE (1974 to September 2008), and the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library, Issue 3, 2008) and listed references. We hand searched conference proceedings to identify published and unpublished trials. SELECTION CRITERIA: We included randomized controlled clinical trials in which standard closure techniques plus a sealant were compared with the same intervention with no use of any sealant in patients undergoing elective pulmonary resection provided that a large proportion of the patients studied had undergone pulmonary resection for lung cancer. DATA COLLECTION AND ANALYSIS: Four reviewers independently selected the trials to be included in the review, assessed methodological quality of each trial and extracted data using a standardized form. Because of several limitations, narrative synthesis was used at this stage. MAIN RESULTS: Sixteen trials, with 1642 randomized patients in total were included. In thirteen trials there were differences between treatment and control patients in reducing postoperative air leaks. This reduction proved to be significant in six trials. Three trials showed a significant reduction in time to chest drain removal in the treatment group. In two trials, the percentage of patients with persistent air leak was significantly smaller in the treatment group. Finally, three trials including 352 patients showed a statistically significant reduction in length of hospital stay. AUTHORS' CONCLUSIONS: Surgical sealants reduce postoperative air leaks and time to chest drain removal but this reduction is not always associated with a reduction in length of postoperative hospital stay. Therefore, systematic use of surgical sealants with the objective of reducing hospital stay cannot be recommended at the moment. More and larger randomized controlled clinical trials are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd003051.pub3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Belda-Sanchís, J., Serra-Mitjans, M., Iglesias Sentis, M., & Rami, R.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2010-01-20
Issue
1
Pages
CD003051-CD003051
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W1479701345
Cited by
163
References
0
FWCI
14.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surgical sealant for preventing air leaks after pulmonary resections in patients with lung cancer. https://app.cochat.ai/papers/10.1002/14651858.cd003051.pub3
The paper
Belda-Sanchís, J., Serra-Mitjans, M., Iglesias Sentis, M., & Rami, R. (2010). Surgical sealant for preventing air leaks after pulmonary resections in patients with lung cancer. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd003051.pub3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.