Interventions for replacing missing teeth: different times for loading dental implants
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To minimise the risk of implant failures after their placement, dental implants are kept load-free for 3 to 8 months to establish osseointegration (conventional loading). It would be beneficial if the healing period could be shortened without jeopardising implant success. Nowadays implants are loaded early and even immediately and it would be useful to know whether there is a difference in success rates between immediately and early loaded implants compared with conventionally loaded implants. OBJECTIVES: To evaluate the effects of (1) immediate (within 1 week), early (between 1 week and 2 months), and conventional (after 2 months) loading of osseointegrated implants; (2) immediate occlusal versus non-occlusal loading and early occlusal versus non-occlusal loading; (3) direct loading versus progressive loading immediately, early and conventionally. SEARCH METHODS: The following electronic databases were searched: the Cochrane Oral Health Group's Trials Register (to 8 June 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, 2012, Issue 4), MEDLINE via OVID (1946 to 8 June 2012) and EMBASE via OVID (1980 to 8 June 2012). Authors of identified trials were contacted to find unpublished randomised controlled trials (RCTs). There were no restrictions regarding language or date of publication. SELECTION CRITERIA: All RCTs of root-form osseointegrated dental implants, having a follow-up of 4 months to 1 year, comparing the same implant type immediately, early or conventionally loaded, occlusally or non-occlusally loaded, or progressively loaded or not. Outcome measures were: prosthesis and implant failures and radiographic marginal bone level changes. DATA COLLECTION AND ANALYSIS: Data were independently extracted, in duplicate, by at least two review authors. Trial authors were contacted for missing information. Risk of bias was assessed for each trial by at least two review authors, and data were extracted independently, and in duplicate. Results were combined using fixed-effect models with mean differences (MD) for continuous outcomes and risk ratios (RR) for dichotomous outcomes with 95% confidence intervals (CI). A summary of findings table of the main findings was constructed. MAIN RESULTS: Forty-five RCTs were identified and, from these, 26 trials including a total of 1217 participants and 2120 implants were included. Three trials were at low risk of bias, 12 were at high risk of bias and for the remaining 11 the risk of bias was unclear. In nine of the included studies there were no prosthetic failures within the first year, with no implant failures in 7 studies and the mean rate of implant failure in all 26 trials was a low 2.5%. From 15 RCTs comparing immediate with convential loading there was no evidence of a difference in either prosthesis failure (RR 1.87; 95% CI 0.70 to 5.01; 8 trials) or implant failure (RR 1.65; 95% CI 0.68 to 3.98; 10 trials) in the first year, but there is some evidence of a small reduction in bone loss favouring immediate loading (MD -0.10 mm; 95% CI -0.20 to -0.01; P = 0.03; 9 trials), with some heterogeneity (Tau² = 0.01; Chi² = 14.37, df = 8 (P = 0.07); I² = 44%). However, this very small difference may not be clinically important. From three RCTs which compared early loading with conventional loading, there is insufficient evidence to determine whether or not there is a clinically important difference in prosthesis failure, implant failure or bone loss. Six RCTs compared immediate and early loading and found insufficient evidence to determine whether or not there is a clinically important difference in prosthesis failure, implant failure or bone loss. From the two trials which compared occlusal loading with non-occlusal loading there is insufficient evidence to determine whether there is a clinically important difference in the outcomes of prosthesis failure, implant failure or bone loss. We did not identify any trials which evaluated progressive loading of implants. AUTHORS' CONCLUSIONS: Overall there was no convincing evidence of a clinically important difference in prosthesis failure, implant failure, or bone loss associated with different loading times of implants. More well-designed RCTs are needed and should be reported according to the CONSORT guidelines (www.consort-statement.org/).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Interventions for replacing missing teeth: different types of dental implants
Esposito, M., Murray-Curtis, L., Grusovin, M. G., Coulthard, P., & Worthington, H. V. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003815.pub3 · Cited by 247
Self-citationRetractedInterventions for replacing missing teeth: different types of dental implants
Esposito, M., Ardebili, Y., & Worthington, H. V. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003815.pub5 · Cited by 243
Self-citationRetractedBias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Meta-analyses involving cross-over trials: methodological issues
Elbourne, D. R., Altman, D. G., Higgins, J. P., Curtin, F., Worthington, H. V., & Vail, A. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.140 · Cited by 2,305
Self-citationTissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556
Variance imputation for overviews of clinical trials with continuous response
Follmann, D., Elliott, P., Suh, I., & Cutler, J. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90054-q · Cited by 1,385
(2010) · Handbook of Disease Burdens and Quality of Life Measures · doi:10.1007/978-0-387-78665-0_6514 · Cited by 1,385
Patient selection and preparation
Lekholm, U. (1985) · Medical Entomology and Zoology · Cited by 1,173
Regeneration of gingival papillae after single-implant treatment.
Jemt, T. (1997) · PubMed · Cited by 581
Osseointegrated Titanium Implants
Holt, G., Parel, S., & Branemark, P. (1986) · Facial Plastic Surgery · doi:10.1055/s-2008-1064831 · Cited by 435
Thorlund, K., Imberger, G., Walsh, M., Chu, R., Gluud, C., Wetterslev, J., Guyatt, G., Devereaux, P. J., & Thabane, L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025491 · Cited by 319
(2008) · British Dental Journal · doi:10.1038/sj.bdj.2008.407 · Cited by 244
Interventions for replacing missing teeth: different times for loading dental implants
Esposito, M., Grusovin, M. G., Achille, H., Coulthard, P., & Worthington, H. V. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003878.pub4 · Cited by 216
Self-citationRoccuzzo, M., Bunino, M., Prioglio, F., & Bianchi, S. D. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120604.x · Cited by 197
Brunski, J., Moccia, A. F., Pollack, S. R., Korostoff, E., & Trachtenberg, D. I. (1979) · Journal of Dental Research · doi:10.1177/00220345790580100301 · Cited by 173
Ganeles, J., Zöllner, A., Jackowski, J., Ten Bruggenkate, C., Beagle, J., & Guerra, F. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01626.x · Cited by 170
Effect of Flapless Implant Surgery on Soft Tissue Profile: A Randomized Controlled Clinical Trial
Oh, T., Shotwell, J. L., Billy, E. J., & Wang, H. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.050169 · Cited by 128
Meta‐analysis combining parallel and cross‐over clinical trials. II: Binary outcomes
Curtin, F., Elbourne, D., & Altman, D. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1206 · Cited by 125
Tawse‐Smith, A., Payne, A. G. T., Kumara, R., & Thomson, W. M. (2002) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2002.tb00149.x · Cited by 113
Interventions for replacing missing teeth: different times for loading dental implants
Esposito, M. A., Grusovin, M. G., Willings, M., Coulthard, P., & Worthington, H. V. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003878.pub3 · Cited by 92
Self-citationZöllner, A., Ganeles, J., Korostoff, J. M., Guerra, F., Krafft, T., & Brägger, U. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01517.x · Cited by 78
Does Loading Time Affect Implant Survival? A Meta‐Analysis of 1,266 Implants
Ioannidou, E., & Doufexi, A. (2005) · Journal of Periodontology · doi:10.1902/jop.2005.76.8.1252 · Cited by 74
Loading Protocols for Mandibular Implant Overdentures: A Systematic Review with Meta‐Analysis
Alsabeeha, N. H. M., Atieh, M. A., & Payne, A. G. T. (2009) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00152.x · Cited by 67
Sennerby, L., & Gottlow, J. (2008) · Australian Dental Journal · doi:10.1111/j.1834-7819.2008.00045.x · Cited by 58
Hall, J. A. G., Payne, A. G. T., Purton, D. G., & Torr, B. (2006) · PubMed · Cited by 48
Merli, M., Moscatelli, M., Mariotti, G., Piemontese, M., & Nieri, M. (2011) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01821.x · Cited by 34
Güncü, G. N., Tözüm, T. F., Güncü, M. B., Yamalık, N., & Tümer, C. (2009) · Implant Dentistry · doi:10.1097/id.0b013e318195aaa3 · Cited by 12
Cited by
Chiapasco, M., & Zaniboni, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01781.x · Cited by 306
Malo, P., de Araújo Nobre, M., Lopes, A., Moss, S. M., & Molina, G. J. (2011) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2011.0170 · Cited by 284
Relationship between sponsorship and failure rate of dental implants: a systematic approach
Popelut, A., Valet, F., Fromentin, O., Thomas, A., & Bouchard, P. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010274 · Cited by 86
Montero, J., Guadilla, Y., Flores, J., Pardal-Peláez, B., Quispe-López, N., Gómez-Polo, C., & Dib, A. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10194589 · Cited by 18
Sarkis-Onofre, R., Marchini, L., Spazzin, A. O., & Santos, M. B. F. D. (2019) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-18-00276 · Cited by 7
Metadata
- Authors
- Esposito, M., Grusovin, M. G., Maghaireh, H., & Worthington, H. V.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2013-03-28
- Volume
- 2013
- Issue
- 5
- Pages
- CD003878-CD003878
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2109504630
- Cited by
- 550
- References
- 32
- FWCI
- 52.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.