The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fetal pulse oximetry for fetal assessment in labour
Open accessAbstract
BACKGROUND: The use of conventional cardiotocographic (CTG) monitoring of fetal well-being during labour is associated with an increased caesarean section rate, compared with intermittent auscultation of the fetal heart rate, resulting in a reduction in neonatal seizures, although no differences in other neonatal outcomes. To improve the sensitivity of this test and therefore reduce the number of caesarean sections performed for nonreassuring fetal status, several additional measures of evaluating fetal well-being have been considered. These have demonstrated some effect on reducing caesarean section rates, for example, fetal scalp blood sampling for pH estimation/lactate measurement. The adaptation of pulse oximetry for use in the unborn fetus could potentially contribute to improved evaluation during labour and therefore lead to a reduction in caesarean sections for nonreassuring fetal status, without any change in neonatal outcomes. OBJECTIVES: To compare the effectiveness and safety of fetal intrapartum pulse oximetry with other surveillance techniques. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 May 2014), contacted experts in the field and searched reference lists of retrieved studies. In previous versions of this review, we performed additional searches of MEDLINE, Embase and Current Contents. These searches were discontinued for this review update, as they consistently failed to identify any trials that were not shown in the Cochrane Pregnancy and Childbirth Group's Trials Register. SELECTION CRITERIA: All published and unpublished randomised controlled trials that compared maternal and fetal outcomes when fetal pulse oximetry was used in labour, (i) with or without concurrent use of conventional fetal surveillance, that is, cardiotocography (CTG), compared with using CTG alone or (ii) with or without concurrent use of both CTG and other method(s) of fetal surveillance, such as fetal electrocardiography (ECG) plus CTG. DATA COLLECTION AND ANALYSIS: At least two independent review authors performed data extraction. We sought additional information from the investigators of three of the reported trials. MAIN RESULTS: We included seven published trials: six comparing fetal pulse oximetry and CTG with CTG alone (or when fetal pulse oximetry values were blinded) and one comparing fetal pulse oximetry plus CTG with fetal ECG plus CTG. The published trials, with some unpublished data, were at high risk of bias in terms of the impractical nature of blinding participants and clinicians, as well as high risk or unclear risk of bias for outcome assessor for all but one report. Selection bias, attrition bias, reporting bias and other sources of bias were of low or unclear risk. The trials reported on a total of 8013 pregnancies. Differing entry criteria necessitated separate analyses, rather than meta-analysis of all trials.Systematic review of four trials from 34 weeks not requiring fetal blood sampling (FBS) prior to study entry showed no evidence of differences in the overall caesarean section rate between those monitored with fetal oximetry and those not monitored with fetal pulse oximetry or for whom the fetal pulse oximetry results were masked (average risk ratio (RR) 0.99 using random-effects, 95% confidence intervals (CI) 0.86 to 1.13, n = 4008, I² = 45%). There was evidence of a higher risk of caesarean section in the group with fetal oximetry plus CTG than in the group with fetal ECG plus CTG (one study, n = 180, RR 1.56, 95% CI 1.06 to 2.29). Neonatal seizures and neonatal encephalopathy were rare in both groups. No studies reported details of long-term disability.There was evidence of a decrease in caesarean section for nonreassuring fetal status in the fetal pulse oximetry plus CTG group compared to the CTG group, gestation from 34 weeks (average RR (random-effects) 0.65, 95% CI 0.46 to 0.90, n = 4008, I² = 63%). There was no evidence of differences between groups in caesarean section for dystocia, although the overall incidence rates varied between the trials. AUTHORS' CONCLUSIONS: The addition of fetal pulse oximetry does not reduce overall caesarean section rates. One study found a higher caesarean section rate in the group monitored with fetal pulse oximetry plus CTG, compared with fetal ECG plus CTG. The data provide limited support for the use of fetal pulse oximetry when used in the presence of a nonreassuring CTG, to reduce caesarean section for nonreassuring fetal status. A better method than pulse oximetry is required to enhance the overall evaluation of fetal well-being in labour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A modified test for small‐study effects in meta‐analyses of controlled trials with binary endpoints
Harbord, R. M., Egger, M., & Sterne, J. A. C. (2006) · Statistics in Medicine · doi:10.1002/sim.2380 · Cited by 2,267
MacLennan, A. (1999) · BMJ · doi:10.1136/bmj.319.7216.1054 · Cited by 731
Cited by
Alfirevic, Z., Devane, D., & Gyte, G. M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066 · Cited by 1,035
Alfirevic, Z., Gyte, G. M., Cuthbert, A., & Devane, D. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066.pub3 · Cited by 636
Fetal movement counting for assessment of fetal wellbeing
Mangesi, L., Hofmeyr, G. J., Smith, V., & Smyth, R. M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004909.pub3 · Cited by 255
Obstetric care in low-resource settings: what, who, and how to overcome challenges to scale up?
Hofmeyr, G. J., Haws, R. A., Bergström, S., Lee, A. C., Okong, P., Darmstadt, G. L., Mullany, L. C., Oo, E. K. S., & Lawn, J. E. (2009) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2009.07.017 · Cited by 224
The future of electronic fetal monitoring
Knupp, R. J., Andrews, W. W., & Tita, A. T. N. (2020) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2020.02.004 · Cited by 29
Metadata
- Authors
- East, C. E., Begg, L., Colditz, P. B., & Lau, R.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2014-10-07
- Volume
- 2014
- Issue
- 10
- Pages
- CD004075-CD004075
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1960527655
- Cited by
- 211
- References
- 2
- FWCI
- 30.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fetal pulse oximetry for fetal assessment in labour. https://app.cochat.ai/papers/10.1002/14651858.cd004075.pub4
- The paper
- East, C. E., Begg, L., Colditz, P. B., & Lau, R. (2014). Fetal pulse oximetry for fetal assessment in labour. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd004075.pub4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.