CoChat

Sacral nerve stimulation for faecal incontinence and constipation in adults

Open access
Thaha, Mohamed A, Abukar, Amin A, Thin, Noel N, Ramsanahie, Anthony, Knowles, Charles H · 2015 · Cochrane Database of Systematic Reviews
Cited by 213

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Faecal incontinence (FI) and constipation are both socially-embarrassing and physically-disabling conditions that impair quality of life. For both, surgery may be required in a minority of people when more conservative measures fail. However, the invasiveness and irreversible nature of direct surgery on bowel and sphincter muscles, poor long-term outcomes and well-established compIications makes such procedures unappealing for these benign conditions. A less-invasive surgical option to treat faecal incontinence and constipation is direct, low-voltage stimulation of the sacral nerve roots, termed sacral nerve stimulation (SNS). SNS has become the first line surgical treatment for FI in people failing conservative therapies. Its value in the treatment of constipation is less clear. OBJECTIVES: To assess the effects of sacral nerve stimulation using implanted electrodes for the treatment of faecal incontinence and constipation in adults. SEARCH METHODS: We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, ClinicalTrials.gov, the World Health Organization (WHO) ICTRP and handsearched journals and conference proceedings (searched 5 February 2015), EMBASE (1 January 1947 to 2015 Week 5), and the reference lists of retrieved relevant articles. SELECTION CRITERIA: All randomised or quasi-randomised trials assessing the effects of SNS for faecal incontinence or constipation in adults. DATA COLLECTION AND ANALYSIS: Two review authors independently screened the search results, assessed the methodological quality of the included trials, and undertook data extraction. MAIN RESULTS: Six crossover trials and two parallel group trials were included.Six trials assessed the effects of SNS for FI. In the parallel group trial conducted by Tjandra, 53 participants with severe FI in the SNS group experienced fewer episodes of faecal incontinence compared to the control group who received optimal medical therapy (mean difference (MD) -5.20, 95% confidence interval (CI) -9.15 to -1.25 at 3 months; MD -6.30, 95% CI -10.34 to -2.26 at 12 months). Adverse events were reported in a proportion of participants: pain at implant site (6%), seroma (2%) and excessive tingling in the vaginal region (9%).In the parallel group trial carried out by Thin, 15 participants with FI in the SNS group experienced fewer episodes of FI compared with the percutaneous tibial nerve stimulation (PTNS) group (MD -3.00, 95% CI -6.61 to 0.61 at 3 months; MD -3.20, 95% CI -7.14 to 0.74 at 12 months). Adverse events were reported in three participants: mild ipsilateral leg pain during temporary testing (n = 1); and stimulator-site pain following insertion of neurostimulator (n = 2).In the crossover trial by Leroi 7 of 34 recruited participants were excluded from the crossover due mainly to complications or immediate device failure. Twenty-four of the remaining 27 participants while still blinded chose the period of stimulation they had preferred. Outcomes were reported separately for 19 participants who preferred the 'on' and five who preferred the 'off' period. For the group of 19, the median (range) episodes of faecal incontinence per week fell from 1.7 (0 to 9) during the 'off' period to 0.7 (0 to 5) during the 'on' period; for the group of five, however, the median (range) rose from 1.7 (0 to 11) during the 'off' period compared with 3.7 (0 to 11) during the 'on' period. Four of 27 participants experienced an adverse event resulting in removal of the stimulator.In the crossover trial by Sørensen and colleagues, participants did not experience any FI episodes in either the one-week 'on' or 'off' periods.In the crossover trial by Vaizey, participants reported an average of six, and one, episodes of faecal incontinence per week during the 'off' and 'on' periods respectively in two participants with FI. Neither study reported adverse events.In the crossover trial by Kahlke, 14 participants with FI experienced significantly lower episodes of FI per week during the stimulator 'on' (1 (SD, 1.7)) compared with the 'off' period (8.4 (SD, 8.7)). Adverse events reported include: haematoma formation (n = 3); misplacement of tined lead (1); and pain at stimulator site (n = 1).Two trials assessed SNS for constipation. In the Kenefick trial, the two participants experienced an average of two bowel movements per week during the 'off' crossover period, compared with five during the 'on' period. Abdominal pain and bloating occurred 79% of the time during the 'off' period compared with 33% during the 'on' period. No adverse events occurred. In contrast, in the trial by Dinning with 59 participants, SNS did not improve frequency of bowel movements and 73 adverse events were reported, which included pain at site of the implanted pulse generator (32), wound infection (12), and urological (17) events. AUTHORS' CONCLUSIONS: The li

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd004464.pub3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 213

Metadata

Authors
Thaha, M. A., Abukar, A. A., Thin, N. N., Ramsanahie, A., & Knowles, C. H.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2015-08-24
Volume
2015
Issue
8
Pages
CD004464-CD004464
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W1915041231
Cited by
213
References
1
FWCI
16.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.