Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record.

Intramedullary nails for extracapsular hip fractures in adults

Open access
Queally, Joseph M, Harris, Ella, Handoll, Helen HG, Parker, Martyn J · 2014 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Intramedullary nails may be used for the surgical fixation of extracapsular hip fractures in adults. This is an update of a Cochrane review first published in 2005 and last updated in 2008. OBJECTIVES: To assess the effects (benefits and harms) of different designs of intramedullary nails for treating extracapsular hip fractures in adults. SEARCH METHODS: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (6 January 2014), the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 12, 2013), MEDLINE (1966 to November Week 3, 2013), MEDLINE In-Process & Other Non-Indexed Citations (3 January 2014), EMBASE (1988 to 2014, Week 1) and the World Health Organization (WHO) International Clinical Trials Registry Platform (accessed January 2014). SELECTION CRITERIA: All randomised or quasi-randomised trials comparing different types, or design modifications, of intramedullary nails in the treatment of extracapsular hip fractures in adults. DATA COLLECTION AND ANALYSIS: At least two review authors independently selected studies, assessed risk of bias and extracted data. We performed limited meta-analysis using the fixed-effect model. MAIN RESULTS: We included eight new trials, testing seven new comparisons in this update. Overall, we included 17 trials, testing 12 comparisons of different cephalocondylic nail designs. The trials involved a total of 2130 adults (predominantly female and older people) with mainly unstable trochanteric fractures.All trials were at unclear risk of bias for most domains, with the majority at high risk of detection bias for subjective outcomes. The three quasi-randomised trials were at high risk for selection bias.Four trials (910 participants) compared the proximal femoral nail (PFN) with the Gamma nail. There was no significant difference between the two implants in functional outcome (the very low quality evidence being limited to results from single trials), mortality (low quality evidence: 86/415 versus 80/415; risk ratio (RR) 1.08, 95% confidence interval (CI) 0.82 to 1.41), serious fixation complications (operative fracture of the femur, cut-out, non-union and later fracture of the femur) nor re-operations (low quality evidence: 45/455 versus 36/455; RR 1.25, 95% CI 0.83 to 1.90).Two trials (185 participants) provided very low quality evidence of a lack of clinically significant difference in outcome (functional score, mortality, fracture fixation complications and re-operation) between the ACE trochanteric nail and the Gamma nail.Two trials (200 participants) provided very low quality evidence of a lack of significant difference in outcome (mobility score, pain, fracture fixation complications or re-operations) between the proximal femoral nail antirotation (PFNA) nail and the Gamma 3 nail.Seven of the nine trials evaluating different comparisons provided very low quality evidence of a lack of significant between-group differences in all of the reported main outcomes for the following comparisons: ACE trochanteric nail versus Gamma 3 nail (112 participants); gliding nail versus Gamma nail (80 participants); Russell-Taylor Recon nail versus long Gamma nail (34 participants, all under 50 years); proximal femoral nail antirotation (PFNA) nail versus Targon PF nail (80 participants); dynamically versus statically locked intramedullary hip screw (IMHS) nail (81 participants); sliding versus non-sliding Gamma 3 nail (80 participants, all under 60 years); and long versus standard PFNA nails (40 participants with reverse oblique fractures).The other two single comparison trials also provided very low quality evidence of a lack of significant between-group differences in all of the main outcomes with single exceptions. The trial (215 participants) comparing the ENDOVIS nail versus the IMHS nail found low quality evidence of poorer mobility in the ENDOVIS nail group, where more participants in this group were bedridden after their operation (29/105 versus 18/110; RR 1.69, 95% CI 1.00 to 2.85; P = 0.05). The trial (113 participants) comparing the InterTan nail versus the PFNA II nail found very low quality evidence that more PFNA II group participants experienced thigh pain (3/47 versus 12/46; RR: 0.24, 95% CI 0.07 to 0.81). AUTHORS' CONCLUSIONS: The limited evidence from the randomised trials undertaken to date is insufficient to determine whether there are important differences in outcome between different designs of intramedullary nails used in treating extracapsular hip fractures. Given the evidence of superiority of the sliding hip screw compared with intramedullary nails for extracapsular hip fractures, further studies comparing different designs of intramedullary nails are not a priority. Any new design should be evaluated in a randomised comparison with the sliding hip screw.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd004961.pub4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Queally, J. M., Harris, E., Handoll, H. H., & Parker, M. J.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2014-09-12
Volume
2014
Issue
9
Pages
CD004961-CD004961
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2153840665
Cited by
179
References
0
FWCI
12.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intramedullary nails for extracapsular hip fractures in adults. https://app.cochat.ai/papers/10.1002/14651858.cd004961.pub4
The paper
Queally, J. M., Harris, E., Handoll, H. H., & Parker, M. J. (2014). Intramedullary nails for extracapsular hip fractures in adults. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd004961.pub4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.