The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour
Abstract
BACKGROUND: Cardiotocography (known also as electronic fetal monitoring), records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic), so additional assessments of fetal well-being may be used, or the baby delivered by caesarean section or instrumental vaginal birth. OBJECTIVES: To evaluate the effectiveness of continuous cardiotocography during labour. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group Trials Register (31 December 2012) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with (a) no fetal monitoring, (b) intermittent auscultation (c) intermittent cardiotocography. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed study eligibility, quality and extracted data from included studies. MAIN RESULTS: Thirteen trials were included with over 37,000 women; only two were judged to be of high quality.Compared with intermittent auscultation, continuous cardiotocography showed no significant improvement in overall perinatal death rate (risk ratio (RR) 0.86, 95% confidence interval (CI) 0.59 to 1.23, n = 33,513, 11 trials), but was associated with a halving of neonatal seizures (RR 0.50, 95% CI 0.31 to 0.80, n = 32,386, nine trials). There was no significant difference in cerebral palsy rates (RR 1.75, 95% CI 0.84 to 3.63, n = 13,252, two trials). There was a significant increase in caesarean sections associated with continuous cardiotocography (RR 1.63, 95% CI 1.29 to 2.07, n = 18,861, 11 trials). Women were also more likely to have an instrumental vaginal birth (RR 1.15, 95% CI 1.01 to 1.33, n = 18,615, 10 trials).Data for subgroups of low-risk, high-risk, preterm pregnancies and high-quality trials were consistent with overall results. Access to fetal blood sampling did not appear to influence the difference in neonatal seizures nor any other prespecified outcome. AUTHORS' CONCLUSIONS: Continuous cardiotocography during labour is associated with a reduction in neonatal seizures, but no significant differences in cerebral palsy, infant mortality or other standard measures of neonatal well-being. However, continuous cardiotocography was associated with an increase in caesarean sections and instrumental vaginal births. The challenge is how best to convey these results to women to enable them to make an informed choice without compromising the normality of labour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subgroup analysis in randomised controlled trials: importance, indications, and interpretation
Rothwell, P. M. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17709-5 · Cited by 942
Cited by
Renfrew, M. J., McFadden, A., Bastos, M. H., Campbell, J., Channon, A. A., Cheung, N. F., Silva, D. R. A. D., Downe, S., Kennedy, H. P., Malata, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60789-3 · Cited by 1,297
Miller, S., Abalos, E., Chamillard, M., Ciapponi, A., Colaci, D., Comandé, D., Diaz, V., Geller, S., Hanson, C., Langer, A., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31472-6 · Cited by 1,181
FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography
Ayres‐de‐Campos, D., Spong, C. Y., Chandraharan, E., & Panel, F. I. F. M. E. C. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.06.020 · Cited by 911
Alfirevic, Z., Gyte, G. M., Cuthbert, A., & Devane, D. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066.pub3 · Cited by 636
Self-citationBrocklehurst, P., Field, D., Greene, K., Juszczak, E., Keith, R., Kenyon, S., Linsell, L., Mabey, C., Newburn, M., Plachcinski, R., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30568-8 · Cited by 207
Metadata
- Authors
- Alfirevic, Z., Devane, D., & Gyte, G. M.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- John Wiley & Sons, Ltd
- Published
- 2013-05-31
- Issue
- 5
- Pages
- CD006066-CD006066
- ISSN
- 1361-6137 (ISSN-L)
- OpenAlex
- W4233449079
- Cited by
- 208
- References
- 1
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. https://app.cochat.ai/papers/10.1002/14651858.cd006066.pub2
- The paper
- Alfirevic, Z., Devane, D., & Gyte, G. M. (2013). Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd006066.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.