The DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke
Open accessAbstract
robotic assisted training versus all other intervention, Outcome 1 Activities of daily living at the end of intervention phase..........
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adams, H. P., Bendixen, B. H., Kappelle, L. J., Biller, J., Love, B. B., Gordon, D. L., & Marsh, E. E. (1993) · Stroke · doi:10.1161/01.str.24.1.35 · Cited by 12,335
Hoffmann, T. C., Glasziou, P. P., Boutron, I., Milne, R., Perera, R., Moher, D., Altman, D. G., Barbour, V., Macdonald, H., Johnston, M., et al. (2014) · BMJ · doi:10.1136/bmj.g1687 · Cited by 10,548
Vos, T., Barber, R. M., Bell, B., Bertozzi-Villa, A., Biryukov, S., Bolliger, I., Charlson, F., Davis, A., Degenhardt, L., Dicker, D., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60692-4 · Cited by 6,414
Isolated Hand Paresis: A Case Series
Alstadhaug, K. B., & Sjulstad, A. (2013) · Cerebrovascular Diseases Extra · doi:10.1159/000350708 · Cited by 4,058
Feigin, V. L., Lawes, C. M., Bennett, D. A., Barker-Collo, S. L., & Parag, V. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70025-0 · Cited by 2,855
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Kwakkel, G., Kollen, B. J., van der Grond, J., & Prevo, A. J. H. (2003) · Stroke · doi:10.1161/01.str.0000087172.16305.cd · Cited by 1,412
Robot-Assisted Therapy for Long-Term Upper-Limb Impairment after Stroke
Lo, A. C., Guarino, P. D., Richards, L. G., Haselkorn, J. K., Wittenberg, G. F., Federman, D. G., Ringer, R. J., Wagner, T. H., Krebs, H. I., Volpe, B. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0911341 · Cited by 1,397
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Cited by
Hilkens, N. A., Casolla, B., Leung, T. W., & de Leeuw, F.-E. (2024) · The Lancet · doi:10.1016/s0140-6736(24)00642-1 · Cited by 681
Rodgers, H., Bosomworth, H., Krebs, H. I., van Wijck, F., Howel, D., Wilson, N., Aird, L., Alvarado, N., Andole, S., Cohen, D. L., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31055-4 · Cited by 485
A review on EMG/EEG based control scheme of upper limb rehabilitation robots for stroke patients
Sarhan, S. M., Al-Faiz, M. Z., & Takhakh, A. M. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e18308 · Cited by 41
Metadata
- Authors
- Mehrholz, J., Pohl, M., Platz, T., Kugler, J., & Elsner, B.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2018-09-03
- Volume
- 2018
- Issue
- 9
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W4249847080
- Cited by
- 402
- References
- 104
- FWCI
- 23.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke. https://app.cochat.ai/papers/10.1002/14651858.cd006876.pub5
- The paper
- Mehrholz, J., Pohl, M., Platz, T., Kugler, J., & Elsner, B. (2018). Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd006876.pub5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.