The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cervical assessment by ultrasound for preventing preterm delivery
Open accessAbstract
BACKGROUND: Measurement of cervical length (CL) by transvaginal ultrasound (TVU) is predictive of preterm birth (PTB). It is unclear if this screening test is effective for prevention of PTB. OBJECTIVES: To assess the effectiveness of antenatal management based on transvaginal ultrasound of cervical length (TVU CL) screening for preventing PTB. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 August 2012), reviewed the reference lists of all articles and contacted experts in the field for additional and ongoing trials. SELECTION CRITERIA: Published and unpublished randomized controlled trials including pregnant women between the gestational ages of 14 to 32 weeks screened with TVU CL for risk of PTB. This review focuses exclusively on studies based on knowledge versus no knowledge of TVU CL results. DATA COLLECTION AND ANALYSIS: All potential studies identified from the search were independently assessed for inclusion by three review authors. We also analyzed studies for quality measures and extracted data. MAIN RESULTS: Of the 13 trials identified, five were eligible for inclusion (n = 507). Three included singleton gestations with preterm labor (PTL); one included singleton gestations with preterm premature rupture of membranes (PPROM); and one included twin gestations with or without PTL.In the three trials of singleton gestations with PTL, 290 women were randomized; 147 to knowledge and 143 to no knowledge of TVU CL. Knowledge of TVU CL results was associated with a non-significant decrease in PTB at less than 37 weeks (22.3% versus 34.7%, respectively; average risk ratio 0.59, 95% confidence interval (CI) 0.26 to 1.32; two trials, 242 women) and at less than 34 weeks (6.9% verus 12.6%; RR 0.55, 95% CI 0.25 to 1.20; three trials, 256 women). Delivery occurred at a later gestational age in the knowledge versus no knowledge groups (mean difference (MD) 0.64 weeks, 95% CI 0.03 to 1.25; three trials, 290 women). For all other outcomes for which there were available data (PTB at less than 34 or 28 weeks; birthweight less than 2500 grams; perinatal death; maternal hospitalization; tocolysis; and steroids for fetal lung maturity), there was no evidence of a difference between groups.The trial of singleton gestations with PPROM (n = 92) evaluated as its primary outcome safety of TVU CL in this population, and not its effect on management. There was no evidence of a difference in incidence of maternal and neonatal infections between the TVU CL and no TVU CL groups.In the trial of twin gestations with or without PTL (n = 125), there was no evidence of a difference in PTB at less than 36, 34, or 30 weeks, gestational age at delivery, and other perinatal and maternal outcomes between the TVU CL and the no TVU CL groups. Life-table analysis revealed significantly less PTB at less than 35 weeks in the TVU CL group compared with the no TVU CL group (P = 0.02). AUTHORS' CONCLUSIONS: Currently, there is insufficient evidence to recommend routine screening of asymptomatic or symptomatic pregnant women with TVU CL. Since there is a non-significant association between knowledge of TVU CL results and a lower incidence of PTB at less than 37 weeks in symptomatic women, we encourage further research. Future studies should look at specific populations separately (e.g., singleton versus twins; symptoms of PTL or no such symptoms), report on all pertinent maternal and perinatal outcomes, and include cost-effectiveness analyses. Most importantly, future studies should include a clear protocol for management of women based on TVU CL results, so that it can be easily evaluated and replicated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A modified test for small‐study effects in meta‐analyses of controlled trials with binary endpoints
Harbord, R. M., Egger, M., & Sterne, J. A. C. (2006) · Statistics in Medicine · doi:10.1002/sim.2380 · Cited by 2,267
Deeks, J. J., Altman, D. G., & Bradburn, M. J. (2001) · Systematic Reviews in Health Care · doi:10.1002/9780470693926.ch15 · Cited by 2,163
Cited by
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Self-citationUltrasound for fetal assessment in early pregnancy
Whitworth, M., Bricker, L., & Mullan, C. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007058.pub3 · Cited by 492
Scala, C., Leone Roberti Maggiore, U., Barra, F., Tantari, M., & Ferrero, S. (2019) · Medicina · doi:10.3390/medicina55090550 · Cited by 13
Metadata
- Authors
- Berghella, V., Baxter, J. K., & Hendrix, N. W.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2013-01-31
- Volume
- 9
- Issue
- 1
- Pages
- CD007235-CD007235
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2155161348
- Cited by
- 191
- References
- 2
- FWCI
- 12.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.