Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 400

The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.

Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding

Open access
Wikkelsø, Anne, Wetterslev, Jørn, Møller, Ann Merete, Afshari, Arash·2016·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Severe bleeding and coagulopathy are serious clinical conditions that are associated with high mortality. Thromboelastography (TEG) and thromboelastometry (ROTEM) are increasingly used to guide transfusion strategy but their roles remain disputed. This review was first published in 2011 and updated in January 2016. OBJECTIVES: We assessed the benefits and harms of thromboelastography (TEG)-guided or thromboelastometry (ROTEM)-guided transfusion in adults and children with bleeding. We looked at various outcomes, such as overall mortality and bleeding events, conducted subgroup and sensitivity analyses, examined the role of bias, and applied trial sequential analyses (TSAs) to examine the amount of evidence gathered so far. SEARCH METHODS: In this updated review we identified randomized controlled trials (RCTs) from the following electronic databases: Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 1); MEDLINE; Embase; Science Citation Index Expanded; International Web of Science; CINAHL; LILACS; and the Chinese Biomedical Literature Database (up to 5 January 2016). We contacted trial authors, authors of previous reviews, and manufacturers in the field. The original search was run in October 2010. SELECTION CRITERIA: We included all RCTs, irrespective of blinding or language, that compared transfusion guided by TEG or ROTEM to transfusion guided by clinical judgement, guided by standard laboratory tests, or a combination. We also included interventional algorithms including both TEG or ROTEM in combination with standard laboratory tests or other devices. The primary analysis included trials on TEG or ROTEM versus any comparator. DATA COLLECTION AND ANALYSIS: Two review authors independently abstracted data; we resolved any disagreements by discussion. We presented pooled estimates of the intervention effects on dichotomous outcomes as risk ratio (RR) with 95% confidence intervals (CIs). Due to skewed data, meta-analysis was not provided for continuous outcome data. Our primary outcome measure was all-cause mortality. We performed subgroup and sensitivity analyses to assess the effect based on the presence of coagulopathy of a TEG- or ROTEM-guided algorithm, and in adults and children on various clinical and physiological outcomes. We assessed the risk of bias through assessment of trial methodological components and the risk of random error through TSA. MAIN RESULTS: We included eight new studies (617 participants) in this updated review. In total we included 17 studies (1493 participants). A total of 15 trials provided data for the meta-analyses. We judged only two trials as low risk of bias. The majority of studies included participants undergoing cardiac surgery.We found six ongoing trials but were unable to retrieve any data from them. Compared with transfusion guided by any method, TEG or ROTEM seemed to reduce overall mortality (7.4% versus 3.9%; risk ratio (RR) 0.52, 95% CI 0.28 to 0.95; I(2) = 0%, 8 studies, 717 participants, low quality of evidence) but only eight trials provided data on mortality, and two were zero event trials. Our analyses demonstrated a statistically significant effect of TEG or ROTEM compared to any comparison on the proportion of participants transfused with pooled red blood cells (PRBCs) (RR 0.86, 95% CI 0.79 to 0.94; I(2) = 0%, 10 studies, 832 participants, low quality of evidence), fresh frozen plasma (FFP) (RR 0.57, 95% CI 0.33 to 0.96; I(2) = 86%, 8 studies, 761 participants, low quality of evidence), platelets (RR 0.73, 95% CI 0.60 to 0.88; I(2) = 0%, 10 studies, 832 participants, low quality of evidence), and overall haemostatic transfusion with FFP or platelets (low quality of evidence). Meta-analyses also showed fewer participants with dialysis-dependent renal failure.We found no difference in the proportion needing surgical reinterventions (RR 0.75, 95% CI 0.50 to 1.10; I(2) = 0%, 9 studies, 887 participants, low quality of evidence) and excessive bleeding events or massive transfusion (RR 0.38, 95% CI 0.38 to 1.77; I(2) = 34%, 2 studies, 280 participants, low quality of evidence). The planned subgroup analyses failed to show any significant differences.We graded the quality of evidence as low based on the high risk of bias in the studies, large heterogeneity, low number of events, imprecision, and indirectness. TSA indicates that only 54% of required information size has been reached so far in regards to mortality, while there may be evidence of benefit for transfusion outcomes. Overall, evaluated outcomes were consistent with a benefit in favour of a TEG- or ROTEM-guided transfusion in bleeding patients. AUTHORS' CONCLUSIONS: There is growing evidence that application of TEG- or ROTEM-guided transfusion strategies may reduce the need for blood products, and improve morbidity in patients with bleeding. However, these results are primarily based on trials of elective cardiac surgery involving cardiopulmonary bypass, and the level of e

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd007871.pub3

Cites

82 of 82 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 82 references

Cited by

See all 400

Metadata

Authors
Wikkelsø, A., Wetterslev, J., Møller, A. M., & Afshari, A.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2016-08-22
Volume
2018
Issue
12
Pages
CD007871-CD007871
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2512686624
Cited by
400
References
82
FWCI
34.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding. https://app.cochat.ai/papers/10.1002/14651858.cd007871.pub3
The paper
Wikkelsø, A., Wetterslev, J., Møller, A. M., & Afshari, A. (2016). Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd007871.pub3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.