CoChat

Pacing for drug-refractory or drug-intolerant hypertrophic cardiomyopathy

Open access
Qintar, Mohammed, Morad, Abdulrahman, Alhawasli, Hazem, Shorbaji, Khaled, Firwana, Belal, Essali, Adib, Kadro, Waleed · 2012 · Cochrane Database of Systematic Reviews
Cited by 36

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is a genetic disease with an autosomal-dominant inheritance for which negative inotropes are the most widely used initial therapies. Observational studies and small randomised trials have suggested symptomatic and functional benefits using pacing and several theories have been put forward to explain why. Pacing, although not the primary treatment for HCM, could be beneficial to patients with relative or absolute contraindications to surgery or alcohol ablation. Several randomised controlled trials comparing pacing to other therapeutic modalities have been conducted but no Cochrane-style systematic review has been done. OBJECTIVES: To assess the effects of pacing in drug-refractory or drug-intolerant hypertrophic cardiomyopathy patients. SEARCH METHODS: We searched the following on the 14/4/2010: CENTRAL (The Cochrane Library 2010, Issue 1), MEDLINE OVID (from 1950 onwards ), EMBASE OVID (from 1980 onwards ), Web of Science with Conference Proceedings (from 1970 onwards). No language restrictions were applied. SELECTION CRITERIA: Randomised controlled trials of either parallel or crossover design that assess the beneficial and harmful effects of pacing for hypertrophic cardiomyopathy were included. When crossover studies were identified, we considered data only from the first phase. DATA COLLECTION AND ANALYSIS: Data from included studies were extracted onto a pre-formed data extraction paper by two authors independently. Data was then entered into Review Manager 5.1 for analysis. Risk of bias was assessed using the guidance provided in the Cochrane Handbook. For dichotomous data, relative risk was calculated; and for continuous data, the mean differences were calculated. Where appropriate data were available, meta-analysis was performed. Where meta-analysis was not possible, a narrative synthesis was written. A QUROUM flow chart was provided to show the flow of papers. MAIN RESULTS: Five studies (reported in 10 papers) were identified. However, three of the five studies provided un-usable data. Thus the data from only two studies (reported in seven papers) with 105 participants were included for this review. There was insufficient data to compare results on all-cause mortality, cost effectiveness, exercise capacity, Quality of life and Peak O2 consumption.When comparing active pacing versus placebo pacing on exercise capacity, one study showed that exercise time decreased from (13.1 ± 4.4) minutes to (12.6 ± 4.3) minutes in the placebo group and increased from (12.1 ± 5.6) minutes to (12.9 ± 4.2) minutes in the treatment group (MD 0.30; 95% CI -1.54 to 2.14). Statistically significant data from the same study showed that left ventricular outflow tract obstruction decreased from (71 ± 32) mm Hg to (52 ± 34) mm Hg in the placebo group and from (70 ± 24) mm Hg to (33 ± 27) mm Hg in the active pacing group (MD -19.00; 95% CI -32.29 to -5.71). This study was also able to show that New York Heart Association (NYHA) functional class decreased from (2.5 ± 0.5) to (2.2 ± 0.6) in the inactive pacing group and decreased from (2.6 ± 0.5) to (1.7 ± 0.7) in the placebo group (MD -0.50; 95% CI -0.78 to -0.22).When comparing active pacing versus trancoronary ablation of septal hypertrophy (TASH), data from one study showed that NYHA functional class decreased from (3.2 ± 0.7) to (1.5 ± 0.5) in the TASH group and decreased from (3.0 ± 0.1) to (1.9 ± 0.6) in the pacemaker group. This study also showed that LV wall thickness remained unchanged in the active pacing group compared to reduction from (22 ± 4) mm to (17 ± 3) mm in the TASH group (MD 0.60; 95% CI -5.65 to 6.85) and that LV outflow tract obstruction decreased from (80 ± 35.5) mm Hg in the TASH group to (49.3 ± 37.7) mm Hg in the pacemaker group. AUTHORS' CONCLUSIONS: Trials published to date lack information on clinically relevant end-points. Existing data is derived from small trials at high risk of bias, which concentrate on physiological measures. Their results are inconclusive. Further large and high quality trials with more appropriate outcomes are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd008523.pub2

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 36

Metadata

Authors
Qintar, M., Morad, A., Alhawasli, H., Shorbaji, K., Firwana, B., Essali, A., & Kadro, W.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2012-05-16
Volume
2021
Issue
4
Pages
CD008523-CD008523
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W1601753610
Cited by
36
References
4
FWCI
2.11
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.