Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 227

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Negative pressure wound therapy for skin grafts and surgical wounds healing by primary intention

Open access
Webster, Joan, Scuffham, Paul, Stankiewicz, Monica, Chaboyer, Wendy P · 2014 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Indications for the use of negative pressure wound therapy (NPWT) are broadening with a range of systems now available on the market, including those designed for use on clean, closed incisions and skin grafts. Reviews have concluded that the evidence for the effectiveness of NPWT remains uncertain, however, it is a rapidly evolving therapy. Consequently, an updated systematic review of the evidence for the effects of NPWT on postoperative wounds expected to heal by primary intention is required. OBJECTIVES: To assess the effects of NPWT on surgical wounds (primary closure, skin grafting or flap closure) that are expected to heal by primary intention. SEARCH METHODS: We searched the following electronic databases to identify reports of relevant randomised clinical trials: the Cochrane Wounds Group Specialised Register (searched 28 January 2014); the Cochrane Central Register of Controlled Trials (CENTRAL; 2013, issue 12); Database of Abstracts of Reviews of Effects (2013, issue 12); Ovid MEDLINE (2011 to January 2014); Ovid MEDLINE (In-Process & Other Non-Indexed Citations 24 January 2014); Ovid EMBASE (2011 to January 2014 Week 44); and EBSCO CINAHL (2011 to January 2014). We conducted a separate search to identify economic evaluations. SELECTION CRITERIA: We included trials if they allocated patients to treatment randomly and compared NPWT with any other type of wound dressing, or compared one type of NPWT with a different type of NPWT. DATA COLLECTION AND ANALYSIS: We assessed trials for their appropriateness for inclusion and for their quality. This was done by three review authors working independently, using pre-determined inclusion and quality criteria. MAIN RESULTS: In this first update, we included an additional four trials, taking the total number of trials included to nine (785 participants). Three trials involved skin grafts, four included orthopaedic patients and two included general surgery and trauma surgery patients; all the included trials had unclear or high risk of bias for one or more of the quality indicators we assessed. Seven trials compared NPWT with a standard dressing (two of these were 'home-made' NPWT devices), one trial compared one 'home-made' NPWT with a commercially available device. In trials where the individual was the unit of randomisation, there were no differences in the incidence of surgical site infections (SSI); wound dehiscence, re-operation (in incisional wounds); seroma/haematoma; or failed skin grafts. Lower re-operation rates were observed among skin graft patients in the 'home-made' NPWT group (7/65; 10.8%) compared to the standard dressing group (17/66; 25.8%) (risk ratio (RR) 0.42; 95% CI 0.19 to 0.92). The mean cost to supply equipment for VAC® therapy was USD 96.51/day compared to USD 4.22/day for one of the 'home-made' devices (P value 0.01); labour costs for dressing changes were similar for both treatments. Pain intensity score was also reported to be lower in the 'home-made' group when compared with the VAC® group (P value 0.02). One of the trials in orthopaedic patients was stopped early because of a high incidence of fracture blisters in the NPWT group (15/24; 62.5%) compared with the standard dressing group (3/36; 8.3%) (RR 7.50; 95% CI 2.43 to 23.14). AUTHORS' CONCLUSIONS: Evidence for the effects of negative pressure wound therapy (NPWT) for reducing SSI and wound dehiscence remains unclear, as does the effect of NPWT on time to complete healing. Rates of graft loss may be lower when NPWT is used, but hospital-designed and built products are as effective in this area as commercial applications. There are clear cost benefits when non-commercial systems are used to create the negative pressure required for wound therapy, with no evidence of a negative effect on clinical outcome. In one study, pain levels were also rated lower when a 'home-made' system was compared with a commercial counterpart. The high incidence of blisters occurring when NPWT is used following orthopaedic surgery suggests that the therapy should be limited until safety in this population is established. Given the cost and widespread use of NPWT, there is an urgent need for suitably powered, high-quality trials to evaluate the effects of the newer NPWT products that are designed for use on clean, closed surgical incisions. Such trials should focus initially on wounds that may be difficult to heal, such as sternal wounds or incisions on obese patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd009261.pub3

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 227

Metadata

Authors
Webster, J., Scuffham, P., Stankiewicz, M., & Chaboyer, W. P.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2014-10-07
Issue
10
Pages
CD009261-CD009261
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2107542171
Cited by
227
References
3
FWCI
26.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.