The DOI matches its Crossref record; 191 of the 191 references it cites were found in a registry or an index.
Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff
Open accessAbstract
BACKGROUND: In epidemics of highly infectious diseases, such as Ebola, severe acute respiratory syndrome (SARS), or coronavirus (COVID-19), healthcare workers (HCW) are at much greater risk of infection than the general population, due to their contact with patients' contaminated body fluids. Personal protective equipment (PPE) can reduce the risk by covering exposed body parts. It is unclear which type of PPE protects best, what is the best way to put PPE on (i.e. donning) or to remove PPE (i.e. doffing), and how to train HCWs to use PPE as instructed. OBJECTIVES: To evaluate which type of full-body PPE and which method of donning or doffing PPE have the least risk of contamination or infection for HCW, and which training methods increase compliance with PPE protocols. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase and CINAHL to 20 March 2020. SELECTION CRITERIA: We included all controlled studies that evaluated the effect of full-body PPE used by HCW exposed to highly infectious diseases, on the risk of infection, contamination, or noncompliance with protocols. We also included studies that compared the effect of various ways of donning or doffing PPE, and the effects of training on the same outcomes. DATA COLLECTION AND ANALYSIS: Two review authors independently selected studies, extracted data and assessed the risk of bias in included trials. We conducted random-effects meta-analyses were appropriate. MAIN RESULTS: Earlier versions of this review were published in 2016 and 2019. In this update, we included 24 studies with 2278 participants, of which 14 were randomised controlled trials (RCT), one was a quasi-RCT and nine had a non-randomised design. Eight studies compared types of PPE. Six studies evaluated adapted PPE. Eight studies compared donning and doffing processes and three studies evaluated types of training. Eighteen studies used simulated exposure with fluorescent markers or harmless microbes. In simulation studies, median contamination rates were 25% for the intervention and 67% for the control groups. Evidence for all outcomes is of very low certainty unless otherwise stated because it is based on one or two studies, the indirectness of the evidence in simulation studies and because of risk of bias. Types of PPE The use of a powered, air-purifying respirator with coverall may protect against the risk of contamination better than a N95 mask and gown (risk ratio (RR) 0.27, 95% confidence interval (CI) 0.17 to 0.43) but was more difficult to don (non-compliance: RR 7.5, 95% CI 1.81 to 31.1). In one RCT (59 participants) coveralls were more difficult to doff than isolation gowns (very low-certainty evidence). Gowns may protect better against contamination than aprons (small patches: mean difference (MD) -10.28, 95% CI -14.77 to -5.79). PPE made of more breathable material may lead to a similar number of spots on the trunk (MD 1.60, 95% CI -0.15 to 3.35) compared to more water-repellent material but may have greater user satisfaction (MD -0.46, 95% CI -0.84 to -0.08, scale of 1 to 5). According to three studies that tested more recently introduced full-body PPE ensembles, there may be no difference in contamination. Modified PPE versus standard PPE The following modifications to PPE design may lead to less contamination compared to standard PPE: sealed gown and glove combination (RR 0.27, 95% CI 0.09 to 0.78), a better fitting gown around the neck, wrists and hands (RR 0.08, 95% CI 0.01 to 0.55), a better cover of the gown-wrist interface (RR 0.45, 95% CI 0.26 to 0.78, low-certainty evidence), added tabs to grab to facilitate doffing of masks (RR 0.33, 95% CI 0.14 to 0.80) or gloves (RR 0.22, 95% CI 0.15 to 0.31). Donning and doffing Using Centers for Disease Control and Prevention (CDC) recommendations for doffing may lead to less contamination compared to no guidance (small patches: MD -5.44, 95% CI -7.43 to -3.45). One-step removal of gloves and gown may lead to less bacterial contamination (RR 0.20, 95% CI 0.05 to 0.77) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28) than separate removal. Double-gloving may lead to less viral or bacterial contamination compared to single gloving (RR 0.34, 95% CI 0.17 to 0.66) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28). Additional spoken instruction may lead to fewer errors in doffing (MD -0.9, 95% CI -1.4 to -0.4) and to fewer contamination spots (MD -5, 95% CI -8.08 to -1.92). Extra sanitation of gloves before doffing with quaternary ammonium or bleach may decrease contamination, but not alcohol-based hand rub. Training The use of additional computer simulation may lead to fewer errors in doffing (MD -1.2, 95% CI -1.6 to -0.7). A video lecture on donning PPE may lead to better skills scores (MD 30.70, 95% CI 20.14 to 41.26) than a traditional lecture. Face-to-face instruction may reduce noncompliance with doffing guidance more (odds ratio 0.45, 95% CI 0.21 to 0.98) than providing folders or video
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions
Sterne, J. A., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., et al. (2016) · BMJ · doi:10.1136/bmj.i4919 · Cited by 20,329
Wang, D., Hu, B., Hu, C., Zhu, F., Liu, X., Zhang, J., Wang, B., Xiang, H., Cheng, Z., Xiong, Y., et al. (2020) · JAMA · doi:10.1001/jama.2020.1585 · Cited by 20,148
La certeza de lo impredecible: Cultura Educación y Sociedad en tiempos de COVID19
Martínez González, M. (2020) · DSPACE System - Metalibrary (University of the Coast) · Cited by 18,463
(2008) · Cited by 3,790
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
COVID-19 and Italy: what next?
Remuzzi, A., & Remuzzi, G. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30627-9 · Cited by 3,119
A Major Outbreak of Severe Acute Respiratory Syndrome in Hong Kong
Lee, N., Hui, D., Wu, A., Chan, P., Cameron, P., Joynt, G. M., Ahuja, A., Yung, M. Y., Leung, C. B., To, K. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030685 · Cited by 2,628
Research works printed but not linked: 57
- Casanova, Assessment of self-contamination during removal of personal protective equipment for Ebola patient care, Infection Control and Hospital Epidemiology, 37, 1156, 10.1017/ice.2016.169 · doi:10.1017/ice.2016.169
- Curtis, 2018, Video-based learning vs traditional lecture for instructing emergency medicine residents in disaster medicine principles of mass triage, decontamination, and personal protective equipment, Prehospital and Disaster Medicine, 33, 7, 10.1017/S1049023X1700718X · doi:10.1017/s1049023x1700718x
- Gleser, 2018, Modified gloves: a chance for the prevention of nosocomial infections, American Journal of Infection Control, 46, 266, 10.1016/j.ajic.2017.08.024 · doi:10.1016/j.ajic.2017.08.024
- Hajar, 2019, A crossover trial comparing contamination of healthcare personnel during removal of a standard gown versus a modified gown with increased skin coverage at the hands and wrists, Infection Control and Hospital Epidemiology, 40, 1278, 10.1017/ice.2019.211 · doi:10.1017/ice.2019.211
- Robinson, 2018, Effect of glove disinfection on bacterial contamination of healthcare worker hands, Open Forum Infectious Diseases, 5 Suppl 1, S56, 10.1093/ofid/ofy209.135 · doi:10.1093/ofid/ofy209.135
- Mana, 2018, A randomized trial of two cover gowns comparing contamination of healthcare personnel during removal of personal protective equipment, Infection Control and Hospital Epidemiology, 39, 97, 10.1017/ice.2017.249 · doi:10.1017/ice.2017.249
- Osei-Bonsu, 2019, Alternative doffing strategies of personal protective equipment to prevent self-contamination in the health care setting, American Journal of Infection Control, 47, 534, 10.1016/j.ajic.2018.11.003 · doi:10.1016/j.ajic.2018.11.003
- Tomas, 2016, Seamless suits: reducing personnel contamination through improved personal protective equipment design, Infection Control and Hospital Epidemiology, 37, 742, 10.1017/ice.2016.79 · doi:10.1017/ice.2016.79
- Abualenain, 2018, Simulation-based training in Ebola personal protective equipment for healthcare workers: experience from King Abdulaziz University Hospital in Saudi Arabia, Journal of Infection and Public Health, 11, 796, 10.1016/j.jiph.2018.05.002 · doi:10.1016/j.jiph.2018.05.002
- Beam, 2016, Personal protective equipment processes and rationale for the Nebraska Biocontainment Unit during the 2014 activations for Ebola virus disease, American Journal of Infection Control, 44, 340, 10.1016/j.ajic.2015.09.031 · doi:10.1016/j.ajic.2015.09.031
- Beam, 2016, Call for improvement in personal protective equipment guidance and research, American Journal of Infection Control, 44, 1428, 10.1016/j.ajic.2016.05.040 · doi:10.1016/j.ajic.2016.05.040
- Bosc, 2016, Impact of the personal protective equipment for Ebola virus disease on vascular access skills and the performance of airway: a manikin study, Annales Francaises de Medecine d'Urgence, 6, 172, 10.1007/s13341-016-0631-2 · doi:10.1007/s13341-016-0631-2
- Butt, 2016, Infection control and prevention practices implemented to reduce transmission risk of Middle East respiratory syndrome-coronavirus in a tertiary care institution in Saudi Arabia, American Journal of Infection Control, 44, 605, 10.1016/j.ajic.2016.01.004 · doi:10.1016/j.ajic.2016.01.004
- Casanova, 2018, Assessing viral transfer during doffing of Ebola-level personal protective equipment in a biocontainment unit, Clinical Infectious Diseases, 66, 945, 10.1093/cid/cix956 · doi:10.1093/cid/cix956
- Chandramohan, 2018, "All eyes on you": a covert observational study on contact precaution compliance in six hospitals at the Detroit Medical Center, Open Forum Infectious Diseases, 5 Suppl 1, S173, 10.1093/ofid/ofy210.471 · doi:10.1093/ofid/ofy210.471
- Doll, 2017, Acceptability and necessity of training for optimal personal protective equipment use, Infection Control and Hospital Epidemiology, 38, 226, 10.1017/ice.2016.252 · doi:10.1017/ice.2016.252
- Doll, 2017, Acceptability and necessity of training for optimal personal protective equipment use, Infection Control and Hospital Epidemiology, 38, 226, 10.1017/ice.2016.252 · doi:10.1017/ice.2016.252
- Doshi, 2016, Seroprevalence of Ebola virus among health care workers in the Tshuapa district, Democratic Republic of the Congo, American Journal of Tropical Medicine and Hygiene, 95, 50
- DuBose, 2018, Design strategies to improve healthcare worker safety in biocontainment units: learning from Ebola preparedness, Infection Control and Hospital Epidemiology, 39, 961, 10.1017/ice.2018.125 · doi:10.1017/ice.2018.125
- Elcin, 2016, Developing a simulation-based training program for the prehospital professionals and students on the management of Middle East respiratory syndrome, Simulation in Healthcare, 11, 394, 10.1097/SIH.0000000000000198 · doi:10.1097/sih.0000000000000198
- Foote, 2017, Assessment of hospital emergency department response to potentially infectious diseases using unannounced mystery patient drills - New York city, 2016, MMWR. Morbidity and Mortality Weekly Report, 66, 945, 10.15585/mmwr.mm6636a2 · doi:10.15585/mmwr.mm6636a2
- Garibaldi, 2019, A novel personal protective equipment coverall was rated higher than standard Ebola virus personal protective equipment in terms of comfort, mobility and perception of safety when tested by health care workers in Liberia and in a United States biocontainment unit, American Journal of Infection Control, 47, 298, 10.1016/j.ajic.2018.08.014 · doi:10.1016/j.ajic.2018.08.014
- Grélot, Moderate thermal strain in healthcare workers wearing personal protective equipment during treatment and care activities in the context of the 2014 Ebola virus disease outbreak, Journal of Infectious Diseases, 212, 1462
- Herlihey, 2017, The impact of environmental design on doffing personal protective equipment in a healthcare environment: a formative human factors trial, Infection Control and Hospital Epidemiology, 38, 712, 10.1017/ice.2017.68 · doi:10.1017/ice.2017.68
- Jones, 2020, A systematic risk-based strategy to select personal protective equipment for infectious diseases, American Journal of Infection Control, 48, 46, 10.1016/j.ajic.2019.06.023 · doi:10.1016/j.ajic.2019.06.023
- Kahveci, 2019, Critical investigation of glove-gown interface barrier performance in simulated surgical settings, Journal of Occupational and Environmental Hygiene, 16, 498, 10.1080/15459624.2019.1600702 · doi:10.1080/15459624.2019.1600702
- Kang, 2017, Difficulties in using personal protective equipment: training experiences with the 2015 outbreak of Middle East respiratory syndrome in Korea, Antimicrobial Resistance and Infection Control, 6, 53
- Kappes Ramirez, 2018, Influence of undergraduate nursing student teaching methods on learning standard precautions and transmission-based precautions: Experimental research., Nurse Education Today, 61, 101, 10.1016/j.nedt.2017.11.007 · doi:10.1016/j.nedt.2017.11.007
- Kilinc-Balci, 2015, Evaluation of the performance of isolation gowns, American Journal of Infection Control, 43, S44, 10.1016/j.ajic.2015.04.112 · doi:10.1016/j.ajic.2015.04.112
- Kogutt, 2019, 680: Assessing effectiveness of PPE in a simulated SVD of a highly infectious disease patient, American Journal of Obstetrics and Gynecology, 220, S451, 10.1016/j.ajog.2018.11.703 · doi:10.1016/j.ajog.2018.11.703
- Kratz, 2017, Discussion of two infection prevention and control training approaches to enhance biosafety in primary healthcare facilities during an outbreak of Ebola virus disease, Tropical Medicine and International Health, 22, 167
- Kwon, 2016, Healthcare worker self-contamination during standard and Ebola virus disease personal protective equipment doffing, Open Forum Infectious Diseases, 3, Supplement 1, 10.1093/ofid/ofw172.1090 · doi:10.1093/ofid/ofw172.1090
- Lee, 2017, Which personal protective equipment to provide? Challenges during the Ebola outbreak and lessons learned, Tropical Medicine and International Health, 22, 29
- Lu, 2020, Integrated infection control strategy to minimize nosocomial infection of corona virus disease 2019 among ENT healthcare workers, Journal of Hospital Infection, 104, PII: S0195, 10.1016/j.jhin.2020.02.018 · doi:10.1016/j.jhin.2020.02.018
- McLaws, 2016, A highly precautionary doffing sequence for health care workers after caring for wet Ebola patients to further reduce occupational acquisition of Ebola, American Journal of Infection Control, 44, 740, 10.1016/j.ajic.2015.12.034 · doi:10.1016/j.ajic.2015.12.034
- Nikiforuk, 2017, Challenge of liquid stressed protective materials and environmental persistence of Ebola virus, Scientific Reports, 7, 4388, 10.1038/s41598-017-04137-2 · doi:10.1038/s41598-017-04137-2
- Novosad, 2016, Evaluating healthcare workers for acquisition of Zika virus while providing critical care, Open Forum Infectious Diseases, 3, Supplement 1, 10.1093/ofid/ofw195.04 · doi:10.1093/ofid/ofw195.04
- Parveen, 2018, Identifying acceptable and feasible infection control interventions for Nipah encephalitis outbreaks in Bangladesh, American Journal of Infection Control, 46, S24, 10.1016/j.ajic.2018.04.041 · doi:10.1016/j.ajic.2018.04.041
- Phan, 2018, Environmental and body contamination from cleaning vomitus in a health care setting: a simulation study, American Journal of Infection Control, 46, 397, 10.1016/j.ajic.2017.10.003 · doi:10.1016/j.ajic.2017.10.003
- Porteous, 2018, A simulation study to evaluate improvements in anesthesia work environment contamination after implementation of an infection prevention bundle, Anesthesia and Analgesia, 127, 662, 10.1213/ANE.0000000000002764 · doi:10.1213/ane.0000000000002764
- Rosenberg, 2016, A simple intervention reduces contamination risk in health care personnel, American Journal of Nursing, 116, 64
- Scott Taylor, 2017, Comparison of intubation devices in level C personal protective equipment: a cadaveric study, American Journal of Emergency Medicine, 36, 922, 10.1016/j.ajem.2017.10.047 · doi:10.1016/j.ajem.2017.10.047
- Su, 2017, Contact patterns during cleaning of vomitus: a simulation study, American Journal of Infection Control, 45, 1312, 10.1016/j.ajic.2017.07.005 · doi:10.1016/j.ajic.2017.07.005
- Suen, 2017, Reliability of N95 respirators for respiratory protection before, during, and after nursing procedures, American Journal of Infection Control, 45, 974, 10.1016/j.ajic.2017.03.028 · doi:10.1016/j.ajic.2017.03.028
- Tomas, 2016, Utility of a novel reflective marker visualized by flash photography for assessment of personnel contamination during removal of personal protective equipment, Infection Control and Hospital Epidemiology, 37, 711, 10.1017/ice.2016.44 · doi:10.1017/ice.2016.44
- Visnovsky, 2019, Effectiveness of a multisite personal protective equipment (PPE)-free zone intervention in acute care, Infection Control and Hospital Epidemiology, 40, 761, 10.1017/ice.2019.111 · doi:10.1017/ice.2019.111
- Weber, 2018, Environmental and personal protective equipment contamination during simulated healthcare activities, American Journal of Infection Control, 46, S10, 10.1016/j.ajic.2018.04.023 · doi:10.1016/j.ajic.2018.04.023
- Xi, 2016, Improving health care workers' protection against infection of Ebola hemorrhagic fever through video surveillance, American Journal of Infection Control, 44, 922, 10.1016/j.ajic.2016.02.015 · doi:10.1016/j.ajic.2016.02.015
- Veritas Health Innovation Covidence Systematic Review Software 2016
- Deeks JJ Higgins JP Altman DG (editors) on behalf of the Cochrane Statistical Methods Group Chapter 9: Analysing data and undertaking meta-analyses. In: Higgins JPT, Churchill R, Chandler J, Cumpston MS (editors), Cochrane Handbook for Systematic Reviews of Interventions version 5.2.0 (updated June 2017), Cochrane, 2017 Available from www.training.cochrane.org/handbook
- European Center for Disease Prevention and Control Safe use of personal protective equipment in the treatment of infectious diseases of high consequence ECDC 10.2900/339505 · doi:10.2900/339505
- Giwa, 2020, Novel 2019 coronavirus SARS-CoV-2 (COVID-19): an updated overview for emergency clinicians, Emergency Medicine Practice, 22, 1
- Kahveci, 2019, Critical investigation of glove-gown interface barrier performance in simulated surgical settings, Journal of occupational and environmental hygiene, 16, 498/506, 10.1080/15459624.2019.1600702 · doi:10.1080/15459624.2019.1600702
- Nordic Cochrane Centre, The Cochrane Collaboration Review Manager 5 (RevMan 5) 2014
- The Cochrane Collaboration Review Manager Web (RevMan Web) 2019
- Roberge, 2016, Face shields for infection control: a review, Journal of Occupational and Environmental Hygiene, 13, 235, 10.1080/15459624.2015.1095302 · doi:10.1080/15459624.2015.1095302
- Schünemann HJ Oxman AD Vist GE Higgins JP Deeks JJ Glasziou P on behalf of the Cochrane Applicability and Recommendations Methods Group Chapter 12: Interpreting results and drawing conclusions. In: Higgins JPT, Churchill R, Chandler J, Cumpston MS (editors), Cochrane Handbook for Systematic Reviews of Interventions version 5.2.0 (updated June 2017). Cochrane, 2017 Available from www.training.cochrane.org/handbook
Cited by
Chu, D. K., Akl, E. A., Duda, S., Solo, K., Yaacoub, S., Schünemann, H. J., Chu, D. K., Akl, E. A., El-harakeh, A., Bognanni, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31142-9 · Cited by 3,843
Houghton, C., Meskell, P., Delaney, H., Smalle, M., Glenton, C., Booth, A., Chan, X. H. S., Devane, D., & Biesty, L. M. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013582 · Cited by 732
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
MacIntyre, C. R., & Chughtai, A. A. (2020) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103629 · Cited by 319
Metadata
- Authors
- Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2020-04-15
- Volume
- 4
- Pages
- CD011621-CD011621
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1876270687
- Cited by
- 657
- References
- 191
- FWCI
- 15.90
- Type
- journal article
- Language
- en
- Update notices
- new_version (2020-05-15)
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. https://app.cochat.ai/papers/10.1002/14651858.cd011621.pub4
- The paper
- Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020). Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd011621.pub4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.