CoChat

Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation

Open access
Nyong, Jonathan, Amit, Guy, Adler, Alma J, Owolabi, Onikepe O, Perel, Pablo, Prieto-Merino, David, Lambiase, Pier, Casas, Juan Pablo, Morillo, Carlos A · 2016 · Cochrane Database of Systematic Reviews
Cited by 70

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The optimal rhythm management strategy for people with non-paroxysmal (persistent or long-standing persistent) atrial fibrilation is currently not well defined. Antiarrhythmic drugs have been the mainstay of therapy. But recently, in people who have not responded to antiarrhythmic drugs, the use of ablation (catheter and surgical) has emerged as an alternative to maintain sinus rhythm to avoid long-term atrial fibrillation complications. However, evidence from randomised trials about the efficacy and safety of ablation in non-paroxysmal atrial fibrillation is limited. OBJECTIVES: To determine the efficacy and safety of ablation (catheter and surgical) in people with non-paroxysmal (persistent or long-standing persistent) atrial fibrillation compared to antiarrhythmic drugs. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE Ovid, Embase Ovid, conference abstracts, clinical trial registries, and Health Technology Assessment Database. We searched these databases from their inception to 1 April 2016. We used no language restrictions. SELECTION CRITERIA: We included randomised trials evaluating the effect of radiofrequency catheter ablation (RFCA) or surgical ablation compared with antiarrhythmic drugs in adults with non-paroxysmal atrial fibrillation, regardless of any concomitant underlying heart disease, with at least 12 months of follow-up. DATA COLLECTION AND ANALYSIS: Two review authors independently selected studies and extracted data. We evaluated risk of bias using the Cochrane 'Risk of bias' tool. We calculated risk ratios (RRs) for dichotomous data with 95% confidence intervals (CIs) a using fixed-effect model when heterogeneity was low (I² <= 40%) and a random-effects model when heterogeneity was moderate or substantial (I² > 40%). Using the GRADE approach, we evaluated the quality of the evidence and used the GRADE profiler (GRADEpro) to import data from Review Manager 5 to create 'Summary of findings' tables. MAIN RESULTS: We included three randomised trials with 261 participants (mean age: 60 years) comparing RFCA (159 participants) to antiarrhythmic drugs (102) for non-paroxysmal atrial fibrillation. We generally assessed the included studies as having low or unclear risk of bias across multiple domains, with reported outcomes generally lacking precision due to low event rates. Evidence showed that RFCA was superior to antiarrhythmic drugs in achieving freedom from atrial arrhythmias (RR 1.84, 95% CI 1.17 to 2.88; 3 studies, 261 participants; low-quality evidence), reducing the need for cardioversion (RR 0.62, 95% CI 0.47 to 0.82; 3 studies, 261 participants; moderate-quality evidence), and reducing cardiac-related hospitalisation (RR 0.27, 95% CI 0.10 to 0.72; 2 studies, 216 participants; low-quality evidence) at 12 months follow-up. There was substantial uncertainty surrounding the effect of RFCA regarding significant bradycardia (or need for a pacemaker) (RR 0.20, 95% CI 0.02 to 1.63; 3 studies, 261 participants; low-quality evidence), periprocedural complications, and other safety outcomes (RR 0.94, 95% CI 0.16 to 5.68; 3 studies, 261 participants; very low-quality evidence). AUTHORS' CONCLUSIONS: In people with non-paroxysmal atrial fibrillation, evidence suggests a superiority of RFCA to antiarrhythmic drugs in achieving freedom from atrial arrhythmias, reducing the need for cardioversion, and reducing cardiac-related hospitalisations. There was uncertainty surrounding the effect of RFCA with significant bradycardia (or need for a pacemaker), periprocedural complications, and other safety outcomes. Evidence should be interpreted with caution, as event rates were low and quality of evidence ranged from moderate to very low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd012088.pub2

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 70

Metadata

Authors
Nyong, J., Amit, G., Adler, A. J., Owolabi, O. O., Perel, P., Prieto-Merino, D., Lambiase, P., Casas, J. P., & Morillo, C. A.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2016-11-22
Volume
2016
Issue
11
Pages
CD012088-CD012088
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2290009786
Cited by
70
References
20
FWCI
5.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation. https://app.cochat.ai/papers/10.1002/14651858.cd012088.pub2
The paper
Nyong, J., Amit, G., Adler, A. J., Owolabi, O. O., Perel, P., Prieto-Merino, D., Lambiase, P., Casas, J. P., & Morillo, C. A. (2016). Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd012088.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.