CoChat

Automated monitoring compared to standard care for the early detection of sepsis in critically ill patients

Open access
Warttig, Sheryl, Alderson, Phil, Evans, David JW, Lewis, Sharon R, Kourbeti, Irene S, Smith, Andrew F · 2018 · Cochrane Database of Systematic Reviews
Cited by 52

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Sepsis is a life-threatening condition that is usually diagnosed when a patient has a suspected or documented infection, and meets two or more criteria for systemic inflammatory response syndrome (SIRS). The incidence of sepsis is higher among people admitted to critical care settings such as the intensive care unit (ICU) than among people in other settings. If left untreated sepsis can quickly worsen; severe sepsis has a mortality rate of 40% or higher, depending on definition. Recognition of sepsis can be challenging as it usually requires patient data to be combined from multiple unconnected sources, and interpreted correctly, which can be complex and time consuming to do. Electronic systems that are designed to connect information sources together, and automatically collate, analyse, and continuously monitor the information, as well as alerting healthcare staff when pre-determined diagnostic thresholds are met, may offer benefits by facilitating earlier recognition of sepsis and faster initiation of treatment, such as antimicrobial therapy, fluid resuscitation, inotropes, and vasopressors if appropriate. However, there is the possibility that electronic, automated systems do not offer benefits, or even cause harm. This might happen if the systems are unable to correctly detect sepsis (meaning that treatment is not started when it should be, or it is started when it shouldn't be), or healthcare staff may not respond to alerts quickly enough, or get 'alarm fatigue' especially if the alarms go off frequently or give too many false alarms. OBJECTIVES: To evaluate whether automated systems for the early detection of sepsis can reduce the time to appropriate treatment (such as initiation of antibiotics, fluids, inotropes, and vasopressors) and improve clinical outcomes in critically ill patients in the ICU. SEARCH METHODS: We searched CENTRAL; MEDLINE; Embase; CINAHL; ISI Web of science; and LILACS, clinicaltrials.gov, and the World Health Organization trials portal. We searched all databases from their date of inception to 18 September 2017, with no restriction on country or language of publication. SELECTION CRITERIA: We included randomized controlled trials (RCTs) that compared automated sepsis-monitoring systems to standard care (such as paper-based systems) in participants of any age admitted to intensive or critical care units for critical illness. We defined an automated system as any process capable of screening patient records or data (one or more systems) automatically at intervals for markers or characteristics that are indicative of sepsis. We defined critical illness as including, but not limited to postsurgery, trauma, stroke, myocardial infarction, arrhythmia, burns, and hypovolaemic or haemorrhagic shock. We excluded non-randomized studies, quasi-randomized studies, and cross-over studies . We also excluded studies including people already diagnosed with sepsis. DATA COLLECTION AND ANALYSIS: We used the standard methodological procedures expected by Cochrane. Our primary outcomes were: time to initiation of antimicrobial therapy; time to initiation of fluid resuscitation; and 30-day mortality. Secondary outcomes included: length of stay in ICU; failed detection of sepsis; and quality of life. We used GRADE to assess the quality of evidence for each outcome. MAIN RESULTS: We included three RCTs in this review. It was unclear if the RCTs were three separate studies involving 1199 participants in total, or if they were reports from the same study involving fewer participants. We decided to treat the studies separately, as we were unable to make contact with the study authors to clarify.All three RCTs are of very low study quality because of issues with unclear randomization methods, allocation concealment and uncertainty of effect size. Some of the studies were reported as abstracts only and contained limited data, which prevented meaningful analysis and assessment of potential biases.The studies included participants who all received automated electronic monitoring during their hospital stay. Participants were randomized to an intervention group (automated alerts sent from the system) or to usual care (no automated alerts sent from the system).Evidence from all three studies reported 'Time to initiation of antimicrobial therapy'. We were unable to pool the data, but the largest study involving 680 participants reported median time to initiation of antimicrobial therapy in the intervention group of 5.6 hours (interquartile range (IQR) 2.3 to 19.7) in the intervention group (n = not stated) and 7.8 hours (IQR 2.5 to 33.1) in the control group (n = not stated).No studies reported 'Time to initiation of fluid resuscitation' or the adverse event 'Mortality at 30 days'. However very low-quality evidence was available where mortality was reported at other time points. One study involving 77 participants reported 14-day mortality of 20% in the intervention group and 21% in the control group

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd012404.pub2

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 52

Metadata

Authors
Warttig, S., Alderson, P., Evans, D. J., Lewis, S. R., Kourbeti, I. S., & Smith, A. F.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2018-06-25
Volume
2019
Issue
1
Pages
CD012404-CD012404
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2811130423
Cited by
52
References
10
FWCI
4.09
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated monitoring compared to standard care for the early detection of sepsis in critically ill patients. https://app.cochat.ai/papers/10.1002/14651858.cd012404.pub2
The paper
Warttig, S., Alderson, P., Evans, D. J., Lewis, S. R., Kourbeti, I. S., & Smith, A. F. (2018). Automated monitoring compared to standard care for the early detection of sepsis in critically ill patients. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd012404.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.