Cited by 121Sepsis Diagnosis and TreatmentHealthcare Technology and Patient MonitoringElectronic Health Records Systems

Randomized trial of automated, electronic monitoring to facilitate early detection of sepsis in the intensive care unit.

Open access
Hooper, Michael H., Weavind, Lisa, Wheeler, Arthur P., Martin, Jason B., Gowda, Supriya Srinivasa, Semler, Matthew W., Hayes, Rachel M., Albert, Daniel W. +8 more·2012·Critical Care Medicine

Abstract

OBJECTIVE: To determine whether automated identification with physician notification of the systemic inflammatory response syndrome in medical intensive care unit patients expedites early administration of new antibiotics or improvement of other patient outcomes in patients with sepsis. DESIGN: : A prospective randomized, controlled, single center study. SETTING: Medical intensive care unit of an academic, tertiary care medical center. PATIENTS: Four hundred forty-two consecutive patients admitted over a 4-month period who met modified systemic inflammatory response syndrome criteria in a medical intensive care unit. INTERVENTION: Patients were randomized to monitoring by an electronic "Listening Application" to detect modified (systemic inflammatory response syndrome) criteria vs. usual care. The listening application notified physicians in real time when modified systemic inflammatory response syndrome criteria were detected, but did not provide management recommendations. MEASUREMENTS AND MAIN RESULTS: The median time to new antibiotics was similar between the intervention and usual care groups when comparing among all patients (6.0 hr vs. 6.1 hr, p = .95), patients with sepsis (5.3 hr vs. 5.1 hr; p = .90), patients on antibiotics at enrollment (5.2 hr vs. 7.0 hr, p = .27), or patients not on antibiotics at enrollment (5.2 hr vs. 5.1 hr, p = .85). The amount of fluid administered following detection of modified systemic inflammatory response syndrome criteria was similar between groups whether comparing all patients or only patients who were hypotensive at enrollment. Other clinical outcomes including intensive care unit length of stay, hospital length of stay, and mortality were not shown to be different between patients in the intervention and control groups. CONCLUSIONS: Realtime alerts of modified systemic inflammatory response syndrome criteria to physicians in one tertiary care medical intensive care unit were feasible and safe but did not influence measured therapeutic interventions for sepsis or significantly alter clinical outcomes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318250a887

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Interventional studies using traditional SIRS and SOFA alarm systems have not shown significant changes in clinical outcomes.

    “Interventional studies using traditional SIRS and SOFA alarm systems have not shown significant changes in clinical outcomes [48–50].”

    From Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy (2020) · cites this paper as [50]

    The Abstract (Conclusions) and Results report that this modified-SIRS alert trial did not significantly change measured clinical outcomes, including ICU length of stay and mortality. The cited study tested modified SIRS alerts in one ICU; it does not support the sentence’s reference to SOFA alarm systems. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • A pooled analysis of three RCTs did not demonstrate a mortality benefit of active screening (RR 0.90; 95% CI 0.51-1.58).

    “A pooled analysis of three RCTs did not demonstrate a mortality benefit of active screening (RR, 0.90; 95% CI, 0.51-1.58)(33-35).”
  • A pooled analysis of three RCTs did not show a mortality benefit of active sepsis screening (RR 0.90; 95% CI 0.51-1.58).

    “A pooled analysis of three RCTs did not demonstrate a mortality benefit of active screening (RR 0.90; 95% CI 0.51–1.58) [33–35].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hooper, M. H., Weavind, L., Wheeler, A. P., Martin, J. B., Gowda, S. S., Semler, M. W., Hayes, R. M., Albert, D. W., Deane, N. B., Nian, H., Mathe, J. L., Nadas, A., Sztipanovits, J., Miller, A., Bernard, G. R., & Rice, T. W.
Affiliations
  • Eastern Virginia Medical School (US)
  • Vanderbilt University (US)
  • Meharry Medical College (US)
Venue
Critical Care Medicine
Published
2012-07
Volume
40
Issue
7
Pages
2096-2101
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2094915224
Cited by
121
References
19
Citations by year
2026: 1 · 2025: 4 · 2024: 7 · 2023: 8 · 2022: 11 · 2021: 7 · 2020: 13 · 2019: 10 · 2018: 8 · 2017: 17 · 2016: 15 · 2015: 7 · 2014: 5 · 2013: 3 · 2012: 4
FWCI
4.53
Type
journal article
Language
en
Open access
Locations
  • Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health (5rc1lm010310-02)
  • National Heart, Lung, and Blood Institute (R34HL105869, K23HL081431)
  • U.S. National Library of Medicine (1RC1LM010310-01, RC1 LM010310)
  • National Center for Research Resources (KL2RR024977, TL1RR024978, UL1RR024975)
Topics
  • Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
Keywords
sepsis, early detection, systemic inflammatory response syndrome, electronic monitoring, automated alerts, physician notification, antibiotic administration, medical intensive care unit, fluid administration, mortality, length of hospital stay
MeSH terms
Anti-Bacterial Agents, Female, Fluid Therapy, Hospital Information Systems, Humans, Intensive Care Units, Length of Stay, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Sensitivity and Specificity, Medical Records Systems, Computerized, Hospital Mortality, Sepsis, Early Diagnosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review