High-frequency ultrasound for diagnosing skin cancer in adults
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Early, accurate detection of all skin cancer types is essential to guide appropriate management and to improve morbidity and survival. Melanoma and squamous cell carcinoma (SCC) are high-risk skin cancers with the potential to metastasise and ultimately lead to death, whereas basal cell carcinoma (BCC) is usually localised, with potential to infiltrate and damage surrounding tissue. Anxiety around missing early curable cases needs to be balanced against inappropriate referral and unnecessary excision of benign lesions. Ultrasound is a non-invasive imaging technique that relies on the measurement of sound wave reflections from the tissues of the body. At lower frequencies, the deeper structures of the body such as the internal organs can be visualised, while high-frequency ultrasound (HFUS) with transducer frequencies of 20 MHz or more has a much lower depth of tissue penetration but produces a higher resolution image of tissues and structures closer to the skin surface. Used in conjunction with clinical and/or dermoscopic examination of suspected skin cancer, HFUS may offer additional diagnostic information compared to other technologies. OBJECTIVES: To assess the diagnostic accuracy of HFUS to assist in the diagnosis of a) cutaneous invasive melanoma and atypical intraepidermal melanocytic variants, b) cutaneous squamous cell carcinoma (cSCC), and c) basal cell carcinoma (BCC) in adults. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: Studies evaluating HFUS (20 MHz or more) in adults with lesions suspicious for melanoma, cSCC or BCC versus a reference standard of histological confirmation or clinical follow-up. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). Due to scarcity of data and the poor quality of studies, we did not undertake a meta-analysis for this review. For illustrative purposes, we plot estimates of sensitivity and specificity on coupled forest plots. MAIN RESULTS: We included six studies, providing 29 datasets: 20 for diagnosis of melanoma (1125 lesions and 242 melanomas) and 9 for diagnosis of BCC (993 lesions and 119 BCCs). We did not identify any data relating to the diagnosis of cSCC.Studies were generally poorly reported, limiting judgements of methodological quality. Half the studies did not set out to establish test accuracy, and all should be considered preliminary evaluations of the potential usefulness of HFUS. There were particularly high concerns for applicability of findings due to selective study populations and data-driven thresholds for test positivity. Studies reporting qualitative assessments of HFUS images excluded up to 22% of lesions (including some melanomas) due to lack of visualisation in the test.Derived sensitivities for qualitative HFUS characteristics were at least 83% (95% CI 75% to 90%) for the detection of melanoma; the combination of three features (lesions appearing hypoechoic, homogenous and well defined) demonstrating 100% sensitivity in two studies (lower limits of the 95% CIs were 94% and 82%), with variable corresponding specificities of 33% (95% CI 20% to 48%) and 73% (95% CI 57% to 85%), respectively. Quantitative measurement of HFUS outputs in two studies enabled decision thresholds to be set to achieve 100% sensitivity; specificities were 93% (95% CI 77% to 99%) and 65% (95% CI 51% to 76%). It was not possible to make summary statements regarding HFUS accuracy for the diagnosis of BCC due to highly variable sensitivities and specificities. AUTHORS' CONCLUSIONS: Insufficient data are available on the potential value of HFUS in the diagnosis of melanoma or BCC. Given the between-study heterogeneity, unclear to low methodological quality and limited volume of evidence, we cannot draw any implications for practice. The main value of the preliminary studies included may be in providing guidance on the possible components of new diagnostic rules for diagnosis of melanoma or BCC using HFUS that will require future evaluation. A prospective evaluation of HFUS added to visual inspection and dermoscopy alone in a standard healthcare setting, with a clearly defined and representative population of participants, would be required for a full and proper evaluation of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Self-citationSTARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Self-citationEstimating the error rate of a prediction rule: improvement on cross-validation
Efron, B. (1983) · Journal of the American Statistical Association · doi:10.1080/01621459.1983.10477973 · Cited by 2,300
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Grob, J. J., & Bonerandi, J. J. (1998) · Archives of Dermatology · doi:10.1001/archderm.134.1.103-a · Cited by 331
Semiological value of ABCDE criteria in the diagnosis of cutaneous pigmented tumors
Thomas, L., Tranchand, P., Berard, F., Secchi, T., Colin, C., & Moulin, G. (1998) · Dermatology · doi:10.1159/000017969 · Cited by 195
Altamura, D., Avramidis, M., & Menzies, S. W. (2008) · Archives of Dermatology · doi:10.1001/archderm.144.4.502 · Cited by 148
Cited by
Teledermatology for diagnosing skin cancer in adults.
Chuchu, N., Dinnes, J., Takwoingi, Y., Matin, R. N., Bayliss, S. E., Davenport, C., Moreau, J. F., Bassett, O., Godfrey, K., O'Sullivan, C., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013193 · Cited by 175
Self-citationSmartphone applications for triaging adults with skin lesions that are suspicious for melanoma
Chuchu, N., Takwoingi, Y., Dinnes, J., Matin, R. N., Bassett, O., Moreau, J. F., Bayliss, S. E., Davenport, C., Godfrey, K., O'Connell, S., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013192 · Cited by 144
Self-citationZhu, A.-Q., Wang, Q., Shi, Y.-L., Ren, W.-W., Cao, X., Ren, T.-T., Wang, J., Zhang, Y.-Q., Sun, Y.-K., Chen, X.-W., et al. (2024) · EClinicalMedicine · doi:10.1016/j.eclinm.2023.102391 · Cited by 25
Metadata
- Authors
- Dinnes, J., Bamber, J., Chuchu, N., Bayliss, S. E., Takwoingi, Y., Davenport, C., Godfrey, K., O'Sullivan, C., Matin, R. N., Deeks, J. J., Williams, H. C., & Cochrane Skin Cancer Diagnostic Test Accuracy Group
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2018-12-04
- Volume
- 2018
- Issue
- 12
- Pages
- CD013188-CD013188
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2905232115
- Cited by
- 97
- References
- 8
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-frequency ultrasound for diagnosing skin cancer in adults. https://app.cochat.ai/papers/10.1002/14651858.cd013188
- The paper
- Dinnes, J., Bamber, J., Chuchu, N., Bayliss, S. E., Takwoingi, Y., Davenport, C., Godfrey, K., O'Sullivan, C., Matin, R. N., Deeks, J. J., Williams, H. C., & Cochrane Skin Cancer Diagnostic Test Accuracy Group. (2018). High-frequency ultrasound for diagnosing skin cancer in adults. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd013188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.