The DOI matches its Crossref record; 166 of the 166 references it cites were found in a registry or an index.
The promise and the challenges of cryo‐electron tomography
Open accessAbstract
Structural biologists have traditionally approached cellular complexity in a reductionist manner in which the cellular molecular components are fractionated and purified before being studied individually. This ‘divide and conquer’ approach has been highly successful. However, awareness has grown in recent years that biological functions can rarely be attributed to individual macromolecules. Most cellular functions arise from their concerted action, and there is thus a need for methods enabling structural studies performed in situ, ideally in unperturbed cellular environments. Cryo‐electron tomography (Cryo‐ET) combines the power of 3D molecular‐level imaging with the best structural preservation that is physically possible to achieve. Thus, it has a unique potential to reveal the supramolecular architecture or ‘molecular sociology’ of cells and to discover the unexpected. Here, we review state‐of‐the‐art Cryo‐ET workflows, provide examples of biological applications, and discuss what is needed to realize the full potential of Cryo‐ET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/5174 · Cited by 8,161
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
Liquid-Liquid Phase Separation in Biology
Hyman, A. A., Weber, C. A., & Jülicher, F. (2014) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100913-013325 · Cited by 3,155
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
The Cell as a Collection of Protein Machines: Preparing the Next Generation of Molecular Biologists
Alberts, B. (1998) · Cell · doi:10.1016/s0092-8674(00)80922-8 · Cited by 1,411
Accurate determination of local defocus and specimen tilt in electron microscopy
Mindell, J. A., & Grigorieff, N. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(03)00069-8 · Cited by 1,407
Reconstruction of Three Dimensional Structures from Electron Micrographs
DE ROSIER, D. J., & KLUG, A. (1968) · Nature · doi:10.1038/217130a0 · Cited by 1,345
Cited by
AlphaFold2 and the future of structural biology
Cramer, P. (2021) · Nature Structural & Molecular Biology · doi:10.1038/s41594-021-00650-1 · Cited by 364
Tau liquid‐liquid phase separation in neurodegenerative diseases
Boyko, S., & Surewicz, W. K. (2022) · Trends in Cell Biology · doi:10.1016/j.tcb.2022.01.011 · Cited by 215
Barad, B. A., Medina, M., Fuentes, D., Wiseman, R. L., & Grotjahn, D. A. (2023) · Journal of Cell Biology · doi:10.1083/jcb.202204093 · Cited by 81
Determinants shaping the nanoscale architecture of the mouse rod outer segment
Pöge, M., Mahamid, J., Imanishi, S. S., Plitzko, J. M., Palczewski, K., & Baumeister, W. (2021) · eLife · doi:10.7554/elife.72817 · Cited by 50
Self-citationVisualising the cytoskeletal machinery in neuronal growth cones using cryo-electron tomography
Atherton, J., Stouffer, M., Francis, F., & Moores, C. A. (2022) · Journal of Cell Science · doi:10.1242/jcs.259234 · Cited by 34
Metadata
- Authors
- Turk, M., & Baumeister, W.
- Venue
- FEBS Letters
- Publisher
- Wiley
- Published
- 2020-10
- Volume
- 594
- Issue
- 20
- Pages
- 3243-3261
- ISSN
- 0014-5793 (ISSN-L)
- 1873-3468
- OpenAlex
- W3089400930
- Cited by
- 333
- References
- 166
- FWCI
- 14.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The promise and the challenges of cryo‐electron tomography. https://app.cochat.ai/papers/10.1002/1873-3468.13948
- The paper
- Turk, M., & Baumeister, W. (2020). The promise and the challenges of cryo‐electron tomography. FEBS Letters. https://doi.org/10.1002/1873-3468.13948
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.