Cited by 288X-ray Spectroscopy and Fluorescence AnalysisElectron and X-Ray Spectroscopy TechniquesAdvanced X-ray Imaging Techniques

X‐Ray Absorption and X‐Ray Emission Spectroscopy: Theory and Applications

·2016·Wiley eBooks

Integrity signals

Registry

Crossref · 10.1002/9781118844243

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Frequency-domain spectroscopy of complex systems is often realized in the x-ray domain because short-wavelength radiation gives access to inner shells with element-specific binding energies.

    “This challenge is one reason why frequency-domain spectroscopy of complex systems is often realized in the x-ray domain [201].Short-wavelength radiation gives access to inner shells that have element-specific binding energies.”

    From Roadmap of ultrafast x-ray atomic and molecular physics (2018) · cites this paper as [201]

Cited by

Sorted by citations

Venue
Wiley eBooks
Publisher
Wiley
Published
2016-01-22
OpenAlex
W4238102729
Cited by
288
References
0
Citations by year
2026: 12 · 2025: 19 · 2024: 31 · 2023: 27 · 2022: 29 · 2021: 40 · 2020: 30 · 2019: 22 · 2018: 34 · 2017: 31 · 2016: 13
FWCI
10.59
Type
book
Language
en
Open access
closed
Locations
  • Wiley eBooks (publishedVersion)
  • DORA PSI (Paul Scherrer Institute) (submittedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
Keywords
X-ray absorption spectroscopy, X-ray emission spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review