Magnetic resonance spectroscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This chapter summarizes some of the basic concepts of hydrogen MR spectroscopy (MRS). There are two important differences between MRS and MRI. First, MRS signals are normally detected in the absence of a gradient. All molecules are detected in the presence of the same base magnetic field. Second, unlike MRI, relaxation effects are avoided as much as possible in MRS studies. Chemical shift values are measured to a reference frequency. The traditional reference frequency used for 1H is that of tetramethylsilane (TMS). MRS is one application where the use of increased field strengths will cause the spectral appearance to change. Spin coupling involves a pairing interaction between spins on the same molecule that causes the MR signal of each member to be divided. The chapter talks about single voxel techniques and multiple voxel techniques. This is followed by a discussion on spectral analysis and postprocessing and ultra-high field spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seven-Tesla proton magnetic resonance spectroscopic imaging in adult X-linked adrenoleukodystrophy
Ratai, E., Kok, T., Wiggins, C., Wiggins, G., Grant, E., Gagoski, B., O’Neill, G., Adalsteinsson, E., & Eichler, F. (2008) · Archives of Neurology · doi:10.1001/archneur.65.11.1488 · Cited by 37
Cited by
Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA
Mullins, P. G., McGonigle, D. J., O'Gorman, R. L., Puts, N. A. J., Vidyasagar, R., Evans, C. J., & Edden, R. A. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.004 · Cited by 553
Lemaître, G., Martí, R., Freixenet, J., Vilanova, J. C., Walker, P. M., & Meriaudeau, F. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.02.009 · Cited by 348
Discovering imaging endophenotypes for major depression
Hasler, G., & Northoff, G. (2011) · Molecular Psychiatry · doi:10.1038/mp.2011.23 · Cited by 274
An overview of CEST MRI for non-MR physicists
Wu, B., Warnock, G., Zaiss, M., Lin, C., Chen, M., Zhou, Z., Mu, L., Nanz, D., Tuura, R., & Delso, G. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0155-2 · Cited by 274
Application of ’omics technologies to biomarker discovery in inflammatory lung diseases
Wheelock, C. E., Goss, V. M., Balgoma, D., Nicholas, B., Brandsma, J., Skipp, P. J., Snowden, S., Burg, D., D'Amico, A., Horvath, I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00078812 · Cited by 272
Metadata
- Venue
- MRI Basic Principles and Applications
- Publisher
- Wiley
- Published
- 2015-08-07
- Pages
- 162-176
- OpenAlex
- W3150332167
- Cited by
- 78
- References
- 1
- Type
- other
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.