CoChat

Magnetic resonance spectroscopy

Open access
· 2015 · MRI Basic Principles and Applications
Cited by 78

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This chapter summarizes some of the basic concepts of hydrogen MR spectroscopy (MRS). There are two important differences between MRS and MRI. First, MRS signals are normally detected in the absence of a gradient. All molecules are detected in the presence of the same base magnetic field. Second, unlike MRI, relaxation effects are avoided as much as possible in MRS studies. Chemical shift values are measured to a reference frequency. The traditional reference frequency used for 1H is that of tetramethylsilane (TMS). MRS is one application where the use of increased field strengths will cause the spectral appearance to change. Spin coupling involves a pairing interaction between spins on the same molecule that causes the MR signal of each member to be divided. The chapter talks about single voxel techniques and multiple voxel techniques. This is followed by a discussion on spectral analysis and postprocessing and ultra-high field spectroscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/9781119013068.ch13

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 78

Metadata

Venue
MRI Basic Principles and Applications
Publisher
Wiley
Published
2015-08-07
Pages
162-176
OpenAlex
W3150332167
Cited by
78
References
1
Type
other
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.